Ask An Expert

We will Follow up with you within 24 hours.

Thermal Cycler

Thermal cyclers have evolved into indispensable tools for DNA amplification, often regarded as the laboratory's workhorse. They deliver exceptional performance in a compact, user-friendly design. With improved efficiency, superior performance, and faster optimization capabilities, they stand as the ideal choice for laboratories seeking enhanced DNA amplification solutions.

Advanced Thermal Cycler (Basic) LMAT-A100

  • Capacity: 48 wells × 0.2 mL + 48 wells × 0.5 ml
  • Temperature Range: 0 ℃ to 99 ℃
  • Temperature Accuracy: ≤ ± 0.2℃
  • Temperature Uniformity: ≤ ± 0.2 ℃
  • Ramping Rate: 0.1 ℃ to 3 ℃

Advanced Thermal Cycler (Basic) LMAT-A101

  • Block Capacity: 96 wells × 0.2 ml + 77 wells × 0.5 ml
  • Block Temperature Range: 0 ℃ to 99 ℃
  • Temperature Accuracy: ≤ ± 0.2℃
  • Temperature Uniformity: ≤ ± 0.2 ℃
  • Ramping Rate: 0.1 ℃ to 3 ℃
Advanced Thermal Cycler (Basic) LMAT-A200
  • Block Capacity: 48 wells × 0.2 mL + 48 wells × 0.5 mL
  • Block Temperature Range: 0 ℃ - 100 ℃
  • Temperature Accuracy: ≤ ± 0.2 ℃ (35 ℃ ~ 100 ℃)
  • Temperature Uniformity: ≤ ± 0.2 ℃
  • Ramping Rate: Adjustable
Advanced Thermal Cycler (Basic) LMAT-A201
  • Block Capacity: 98 wells × 0.2 mL + 77 wells × 0.5 mL, PCR strips, In-situ plate
  • Block Temperature Range: 0 ℃ to 100 ℃
  • Temperature Accuracy: ≤ ± 0.2 ℃ (35 ℃ ~ 100 ℃)
  • Temperature Uniformity: ≤ ± 0.2 ℃
  • Ramping Rate: Adjustable

Advanced Thermal Cycler (Gradient) LMAT-B100

  • Block Capacity: 48 wells × 0.2 ml + 48 wells × 0.5 ml
  • Block Temperature Range: 0 ℃ to 99 ℃
  • Temperature Accuracy: ≤ + 0.2 ℃
  • Temperature Uniformity: ≤ ± 0.2℃
  • Ramping Rate: 0.1℃ to 3 ℃

Advanced Thermal Cycler (Gradient) LMAT-B101

  • Block Capacity: 96 wells × 0.2 ml + 77 wells × 0.5 ml
  • Block Temperature Range: 0 ℃ to 99 ℃
  • Temperature Accuracy: ≤ ± 0.2 ℃
  • Temperature Uniformity: ≤ ± 0.2℃
  • Ramping Rate: 0.1℃ to 3 ℃
Advanced Thermal Cycler (Gradient) LMAT-B200
  • Block Capacity: 48 wells × 0.2 mL + 48 wells × 0.5 mL
  • Block Temperature Range: 0 ℃ to 100 ℃
  • Temperature Accuracy: ≤ ± 0.2℃ (35 ℃ ~ 100 ℃)
  • Temperature Uniformity: ≤ ± 0.2℃
  • Ramping Rate: Adjustable
Advanced Thermal Cycler (Gradient) LMAT-B201
  • Block Capacity: 96 wells × 0.2 mL + 77 wells × 0.5 mL
  • Block Temperature Range: 0 ℃ to 100 ℃
  • Temperature Accuracy: ≤ ± 0.2℃ (35 ℃ ~ 100 ℃)
  • Temperature Uniformity: ≤ ± 0.2℃
  • Ramping Rate: Adjustable

Advanced Gradient Thermal Cycler LMAG-C201

  • Capacity: 6×16×0.2 ml
  • Tube: 0.2ml tube, 8 strips, Half skirt96 wells plate, No skirt 96 wells plate
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 6 °C/s
  • Uniformity: ≤ ± 0.2 °C

Advanced Gradient Thermal Cycler LMAG-C202

  • Capacity: 96×0.2 ml
  • Tube: 0.2ml tube, 8 strips, Half skirt96 wells plate, No skirt 96 wells plate
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 8 °C/s
  • Uniformity: ≤ ± 0.2 °C
Advanced Gradient Thermal Cycler LMAG-C301
  • Capacity: 384 well
  • Tube: 384 PCR microplate
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 5 °C/s
  • Uniformity: ≤ ± 0.2 °C
Advanced Gradient Thermal Cycler LMAG-C401
  • Capacity: 64×0.2 ml (A Block) + 32×0.2ml (B Block)
  • Tube: 0.2 ml tube, 8 strips
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 5 °C/s
  • Uniformity: ≤ ± 0.2 °C

Advanced Gradient Thermal Cycler LMAG-C402

  • Capacity: 64×0.2 ml (A Block) + 32×0.2ml (B Block)
  • Tube: 0.2 ml tube, 8 strips
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 5 °C/s
  • Uniformity: ≤ ± 0.2 °C

Advanced Gradient Thermal Cycler LMAG-C501

  • Capacity: 64×0.2 ml (A Block) + 32×0.2 ml (B Block)
  • Tube: 0.2 ml tube, 8 strips
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 8 °C/s
  • Uniformity: ≤ ± 0.2 °C
Automatic Gradient thermal cycler LMAG-D601
  • Capacity: 96×0.2 ml
  • Tube: 0.2 ml single tube, 8 tubes, 96-well full skirt plate, 96-well half skirt plate, 96-well no skirt plate
  • Temperature Range: 0 to 100 °C
  • Maximum. Heating Rate: 5 °C/s
  • Maximum. Cooling Rate: 4 °C/s
Dual Block Thermal Cycler LMMB-E101
  • Capacity: 96×0.2 ml
  • Temperature Range: 0 to 100 °C
  • Maximum. Heating Rate: 5 °C/s
  • Maximum. Cooling Rate: 4 °C/s
  • Uniformity: ≤ ± 0.2 °C

Dual Block Thermal Cycler LMMB-E102

  • Capacity: Double 48×0.2 ml
  • Temperature Range: 0 to 100 °C
  • Maximum. Heating Rate: 5 °C/s
  • Maximum. Cooling Rate: 4 °C/s
  • Uniformity: ≤ ± 0.2 °C

Dual Block Thermal Cycler LMMB-E103

  • Capacity: 48×0.2 ml+30×0.5 ml
  • Temperature Range: 0 to 100 °C
  • Maximum. Heating Rate: 5 °C/s
  • Maximum. Cooling Rate: 4 °C/s
  • Uniformity: ≤ ± 0.2 °C
Dual Block Thermal Cycler LMMB-E104
  • Capacity: 384well
  • Temperature Range: 0 to 100 °C
  • Maximum. Heating Rate: 5 °C/s
  • Maximum. Cooling Rate: 4 °C/s
  • Uniformity: ≤ ± 0.2 °C
Gradient thermal cycler LMGT-B101
  • Capacity: 96×0.2 ml
  • Temperature Range: 0 to 100 °C
  • Maximum. Heating Rate: 4.5 °C/s
  • Maximum. Cooling Rate: 4 °C/s
  • Uniformity: ≤ ± 0.2 °C

Gradient thermal cycler LMGT-B102

  • Capacity: 96×0.2 ml+77×0.5 ml
  • Temperature Range: 0 to 100 °C
  • Maximum. Heating Rate: 4.5 °C/s
  • Maximum. Cooling Rate: 4 °C/s
  • Uniformity: ≤ ± 0.2 °C

Gradient thermal cycler LMGT-B103

  • Capacity: 60×0.5 ml
  • Temperature Range: 0 to 100 °C
  • Maximum. Heating Rate: 4.5 °C/s
  • Maximum. Cooling Rate: 4 °C/s
  • Uniformity: ≤ ± 0.2 °C
Gradient thermal cycler LMGT-B104
  • Capacity: 384 well
  • Temperature Range: 0 to 100 °C
  • Maximum. Heating Rate: 4.5 °C/s
  • Maximum. Cooling Rate: 4 °C/s
  • Uniformity: ≤ ± 0.2 °C
Gradient thermal cycler LMGT-B201
  • Capacity: 96×0.2 ml
  • Temperature Range: 0 to 99.9 °C
  • Maximum. Heating Rate: 4.5 °C/s
  • Maximum. Cooling Rate: 4 °C/s
  • Uniformity: ≤ ± 0.3 °C

Gradient thermal cycler LMGT-B202

  • Capacity: 96×0.2 ml+77×0.5 ml
  • Temperature Range: 0 to 99.9 °C
  • Maximum. Heating Rate: 4.5 °C/s
  • Maximum. Cooling Rate: 4 °C/s
  • Uniformity: ≤ ± 0.3 °C

Gradient thermal cycler LMGT-B203

  • Capacity: 60×0.5 ml
  • Temperature Range: 0 to 99.9 °C
  • Maximum. Heating Rate: 4.5 °C/s
  • Maximum. Cooling Rate: 4 °C/s
  • Uniformity: ≤ ± 0.3 °C
Gradient thermal cycler LMGT-B301
  • Capacity: 96×0.2 ml(6 independent 16 well block)
  • Temperature Range: 4 to 100 °C
  • Maximum. Heating Rate: 6 °C/s
  • Maximum. Cooling Rate: 4 °C/s
  • Uniformity: ≤ ± 0.3 °C
Q-Gene Thermal Cycler LMTC-A301
  • Capacity: 16×0.2 ml (4×4 layout)
  • Tube: 0.2 ml single tube
  • Temperature Range: 4 to 100 °C
  • Maximum. Heating Rate: 5 °C/s
  • Maximum. Cooling Rate: 4 °C/s

Q-Gene Thermal Cycler LMTC-A302

  • Capacity: 32×0.2 ml (4×8 layout)
  • Tube: 0.2 ml single tube, 8-strip
  • Temperature Range: 4 to 100 °C
  • Maximum. Heating Rate: 5 °C/s
  • Maximum. Cooling Rate: 4 °C/s

Q-Lab Thermal Cycler LMTC-A201

  • Capacity: 120×80 mm
  • Temperature Range: 0 to 100 °C
  • Maximum. Heating Rate: 4 °C/s
  • Maximum. Cooling Rate: 3 °C/s
  • Uniformity: ≤ ± 0.2 °C
Touch Screen Thermal Cycler (Basic) LMTC-A100
  • Block Capacity: 16 wells x 0.2 mL
  • Block Temperature Range: 0.1 °C - 99.9 °C
  • Temperature Accuracy: ± 0.25 °C
  • Temperature Uniformity: ± 0.25 °C
  • Ramping Rate: Adjustable
Touch Screen Thermal Cycler (Basic) LMTC-A101
  • Block Capacity: 16 wells x 0.2 mL
  • Block Temperature Range: 4 °C - 100 °C
  • Temperature Accuracy: ± 0.25 °C
  • Temperature Uniformity: ± 0.25 °C
  • Ramping Rate: Adjustable

Touch Screen Thermal Cycler (Basic) LMTC-A102

  • Block Capacity: 32 wells x 0.2 mL
  • Block Temperature Range: 4 °C - 100 °C
  • Temperature Accuracy: ± 0.25 °C
  • Temperature Uniformity: ± 0.25 °C
  • Ramping Rate: Adjustable

Touch Screen Thermal Cycler (Basic) LMTC-A103

  • Block Capacity: 32 wells x 0.2 mL
  • Block Temperature Range: 0.1 °C - 99.9 °C
  • Temperature Accuracy: ± 0.25 °C
  • Temperature Uniformity: ± 0.25 °C
  • Ramping Rate: Adjustable
Touch Screen Thermal Cycler (Basic) LMTC-A104
  • Block Capacity: 30 x 0.5 mL , 40 x 0.2 mL , 4 x 12 PCR Strip
  • Block Temperature Range: 4 °C - 99.9 °C
  • Temperature Accuracy: ≤ ± 0.1 °C (55 °C) ; ≤ ± 0.2 °C (≥ 90 °C)
  • Temperature Uniformity: ± 0.2 °C
  • Ramping Rate: 0.1 °C - 4 °C
Touch Screen Thermal Cycler (Basic) LMTC-A105
  • Block Capacity: 48 x 0.2 mL , 6 x 8 PCR Strip
  • Block Temperature Range: 4 °C - 99.9 °C
  • Temperature Accuracy: ≤ ± 0.1 °C (55 °C) ; ≤ ± 0.2 °C (≥ 90 °C)
  • Temperature Uniformity: ± 0.2 °C
  • Ramping Rate: 0.1 °C - 4 °C

Touch Screen Thermal Cycler (Basic) LMTC-A106

  • Block Capacity: 96 wells x 0.2 mL
  • Block Temperature Range: 4 °C - 99.9 °C
  • Temperature Accuracy: ≤ ± 0.1 °C (55 °C) ; ≤ ± 0.2 °C (≥ 90 °C)
  • Temperature Uniformity: ± 0.2 °C
  • Ramping Rate: 0.1 °C - 4 °C

Touch Screen Thermal Cycler (Basic) LMTC-A107

  • Block Temperature Range: 0 °C - 100 °C
  • Temperature Accuracy: ≤ ± 0.2 °C (35 °C - 100 °C)
  • Temperature Uniformity: ± 0.2 °C (95 °C)
  • Ramping Rate: Adjustable
  • Heating Rate: 3.5 °C/s
Touch Screen Thermal Cycler (Basic) LMTC-A108
  • Block Temperature Range: 0 °C - 100 °C
  • Temperature Accuracy: ≤ ± 0.2 °C (35 °C - 100 °C)
  • Temperature Uniformity: ± 0.2 °C (95 °C)
  • Ramping Rate: Adjustable
  • Heating Rate: 3.5 °C/s
Touch Screen Thermal Cycler (Basic) LMTC-A109
  • Block Temperature Range: 0 °C - 100 °C
  • Temperature Accuracy: ≤ ± 0.2 °C (35 °C - 100 °C)
  • Temperature Uniformity: ± 0.2 °C (95 °C)
  • Ramping Rate: Adjustable
  • Heating Rate: 5 °C/s

Touch Screen Thermal Cycler (Gradient) LMTC-B100

  • Block Capacity: 96 x 0.2 mL , 12 x 8 PCR Strip
  • Block Temperature Range: 4 °C - 99.9 °C
  • Temperature Accuracy: ≤ ± 0.1 °C (55 °C) ; ≤ ± 0.2 °C (≥ 90 °C)
  • Temperature Uniformity: ± 0.2 °C
  • Ramping Rate: 0.1 °C - 4 °C

Touch Screen Thermal Cycler (Gradient) LMTC-B101

  • Block Capacity: 96 x 0.2 mL , 12 x 8 PCR Strip
  • Block Temperature Range: 4 °C - 99.9 °C
  • Temperature Accuracy: ≤ ± 0.1 °C (50 °C) ; ≤ ± 0.2 °C (≥ 90 °C)
  • Temperature Uniformity: ± 0.2 °C
  • Ramping Rate: 0.1 °C - 4 °C
Touch Screen Thermal Cycler (Gradient) LMTC-B102
  • Block Capacity: 96 x 0.2 mL , 12 x 8 PCR Strip
  • Block Temperature Range: 4 °C - 99.9 °C
  • Temperature Accuracy: ≤ ± 0.1 °C (50 °C) ; ≤ ± 0.15 °C (≥ 95 °C) ; ≤ ± 0.15 °C (≥ 72 °C)
  • Temperature Uniformity: ± 0.2 °C
  • Ramping Rate: 0.1 °C - 4 °C
Touch Screen Thermal Cycler (Gradient) LMTC-B103
  • Block Capacity: 96 x 0.2 mL , 12 x 8 PCR Strip
  • Block Temperature Range: 4 °C - 99.9 °C
  • Temperature Accuracy: ≤ ± 0.1 °C (50 °C) ; ≤ ± 0.2 °C (≥ 90 °C)
  • Temperature Uniformity: ± 0.3 °C
  • Ramping Rate: 0.1 °C - 4 °C

Touch Screen Thermal Cycler (Gradient) LMTC-B104

  • Block Capacity: 384 wells plate
  • Block Temperature Range: 4 °C - 99.9 °C
  • Temperature Accuracy: ≤ ± 0.1 °C (55 °C) ; ≤ ± 0.2 °C (≥ 90 °C)
  • Temperature Uniformity: ± 0.2 °C
  • Ramping Rate: 0.1 °C - 4 °C

Touch Screen Thermal Cycler (Gradient) LMTC-B105

  • Block Temperature Range: 0 °C - 100 °C
  • Temperature Accuracy: ≤ ± 0.2 °C (35 °C - 100 °C)
  • Temperature Uniformity: ± 0.2 °C (95 °C)
  • Ramping Rate: Adjustable
  • Heating Rate: 3.5 °C/s
Touch Screen Thermal Cycler (Gradient) LMTC-B106
  • Block Temperature Range: 0 °C - 100 °C
  • Temperature Accuracy: ≤ ± 0.2 °C (35 °C - 100 °C)
  • Temperature Uniformity: ± 0.2 °C (95 °C)
  • Ramping Rate: Adjustable
  • Heating Rate: 3.5 °C/s
Touch Screen Thermal Cycler (Gradient) LMTC-B107
  • Block Temperature Range: 0 °C - 100 °C
  • Temperature Accuracy: ≤ ± 0.2 °C (35 °C - 100 °C)
  • Temperature Uniformity: ± 0.2 °C (95 °C)
  • Ramping Rate: Adjustable
  • Heating Rate: 3.5 °C/s

Touch Screen Thermal Cycler (Gradient) LMTC-B108

  • Block Temperature Range: 0 °C - 100 °C
  • Temperature Accuracy: ≤ ± 0.2 °C (35 °C - 100 °C)
  • Temperature Uniformity: ± 0.2 °C (95 °C)
  • Ramping Rate: Adjustable
  • Heating Rate: 3.5 °C/s

Touch Screen Thermal Cycler (Gradient) LMTC-B200

  • Block Capacity: 6 x 16 wells x 0.2 mL , 96 wells x 0.2 mL , 12 x 8 PCR strips
  • Block Temperature Range: 4 °C - 100 °C
  • Temperature Accuracy: 4 °C - 100 °C
  • Temperature Uniformity: ≤ ± 0.15 °C (≥ 90 °C)
  • Ramping Rate: 0.1 °C - 4 °C
Trio Block Thermal Cycler LMTB-E101
  • Capacity: 3×(32×0.2 ml )
  • Temperature Range: 0 to 100 °C
  • Maximum. Heating Rate: 5 °C/s
  • Maximum. Cooling Rate: 4 °C/s
  • Uniformity: ≤ ± 0.3 °C
Trio Block Thermal Cycler LMTB-E102
  • Capacity: 3×(32×0.2 ml )
  • Temperature Range: 0 to 100 °C
  • Maximum. Heating Rate: 5 °C/s
  • Maximum. Cooling Rate: 4 °C/s
  • Uniformity: ≤ ± 0.3 °C

Touch Screen Thermal Cycler (Basic) LMTC-A200

  • Capacity: 96
  • Reaction Volume: 10 to 200ul
  • Tube Type: 96×0.2ml PCR plate, 8×0.2ml PCR tube
  • Block Temperature Range: 4°C to 105°C
  • Heat Lid Temperature Rangs: 30°C to 110°C

Advanced Gradient Thermal Cycler LMAG-C101

  • Capacity: 96×0.2 ml
  • Tube: 0.2 ml tube,8 strips, Half skirt96 wells plate, No skirt 96 wells plate
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 5 °C/s
  • Uniformity: ≤ ± 0.2 °C
Advanced Gradient Thermal Cycler LMAG-C102
  • Capacity: 96×0.2 ml
  • Tube: 0.2 ml tube,8 strips, Full 96 wells plate, Half skirt96 wells plate, No skirt 96 wells plate
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 6 °C/s
  • Uniformity: ≤ ± 0.2 °C
Gradient Thermal Cycler LMGT-A100
  • Capacity: 32 × 0.2 ml (microtubes), 4 × 8 × 0.2 ml (tube strips)
  • Gradient Temperature Range: 30℃ to105℃
  • Maximum. Heating Rate: 5℃/s
  • Heating Lid Temperature Range: 30℃ to110℃
  • Maximum. Cooling Rate: 4℃/s

Gradient Thermal Cycler LMGT-A101

  • Capacity: 96×0.2ml
  • Gradient Temperature Range: 30 to 105℃
  • Maximum. Heating Rate: 5℃ /s
  • Heating Lid Temperature Range: 30℃ to 110℃
  • Maximum. Cooling Rate: 4.5℃ /s