Get Quote

Contact us now to receive a detailed quotation.

Touch Screen Thermal Cycler (Basic) LMTC-A107

Catalog Send Mail Whatsapp

Specifications

Block Temperature Range 0 °C - 100 °C
Temperature Accuracy ≤ ± 0.2 °C (35 °C - 100 °C)
Temperature Uniformity ± 0.2 °C (95 °C)
Ramping Rate Adjustable
Heating Rate 3.5 °C/s
Cooling Rate 3 °C/s
Display Resolution 0.1 °C
Hot-lid Temperature Range 30 °C - 110 °C
Max No. of Steps 30
Max No. of Program 10000
Max No. of Cycles 100
Increment / Decrement Time Available (Long PCR)
Increment / Decrement Temperature Available (Touchdown PCR)
Display 7” Color Touch Screen
Data Output Port USB 2.0 / RS232 / LAN
Power Consumption 600 W
Power Supply AC 175 V / 275 V; 50 / 60 Hz
Dimension 362 x 256 x 255 mm
Net Weight 7.3 Kg

Features

Touch Screen for smooth operation Real time observation on 7” LCD color display Peltier based heating and cooling control Interchangeable modules Automatic calculation of annealing temperature Stepless adjustable Hot-lid to avoid evaporation Auto shut off when temperature is ˂ 30 °C or after cycle Auto pause / start during technical errors Block / Tube temperature control mode

Optional Modules

Model No.ModuleImage
M-0148 Module: 48 wells x 0.2 mL + 48 wells x 0.5 mL 
M-0296 Module: 96 wells x 0.2 mL 
M-0396+77 Module: 96 wells x 0.2 mL + 77 wells x 0.5 mL 
M-05Multi-purpose Module: 96+77 Module and In situ Adaptor 

Similar Products

Touch Screen Thermal Cycler (Basic) LMTC-A106

  • Block Capacity: 96 wells x 0.2 mL
  • Block Temperature Range: 4 °C - 99.9 °C
  • Temperature Accuracy: ≤ ± 0.1 °C (55 °C) ; ≤ ± 0.2 °C (≥ 90 °C)
  • Temperature Uniformity: ± 0.2 °C
  • Ramping Rate: 0.1 °C - 4 °C

Touch Screen Thermal Cycler (Gradient) LMTC-B107

  • Block Temperature Range: 0 °C - 100 °C
  • Temperature Accuracy: ≤ ± 0.2 °C (35 °C - 100 °C)
  • Temperature Uniformity: ± 0.2 °C (95 °C)
  • Ramping Rate: Adjustable
  • Heating Rate: 3.5 °C/s

Touch Screen Thermal Cycler (Basic) LMTC-A104

  • Block Capacity: 30 x 0.5 mL , 40 x 0.2 mL , 4 x 12 PCR Strip
  • Block Temperature Range: 4 °C - 99.9 °C
  • Temperature Accuracy: ≤ ± 0.1 °C (55 °C) ; ≤ ± 0.2 °C (≥ 90 °C)
  • Temperature Uniformity: ± 0.2 °C
  • Ramping Rate: 0.1 °C - 4 °C
Touch Screen Thermal Cycler (Gradient) LMTC-B102
  • Block Capacity: 96 x 0.2 mL , 12 x 8 PCR Strip
  • Block Temperature Range: 4 °C - 99.9 °C
  • Temperature Accuracy: ≤ ± 0.1 °C (50 °C) ; ≤ ± 0.15 °C (≥ 95 °C) ; ≤ ± 0.15 °C (≥ 72 °C)
  • Temperature Uniformity: ± 0.2 °C
  • Ramping Rate: 0.1 °C - 4 °C
Touch Screen Thermal Cycler (Gradient) LMTC-B106
  • Block Temperature Range: 0 °C - 100 °C
  • Temperature Accuracy: ≤ ± 0.2 °C (35 °C - 100 °C)
  • Temperature Uniformity: ± 0.2 °C (95 °C)
  • Ramping Rate: Adjustable
  • Heating Rate: 3.5 °C/s

Touch Screen Thermal Cycler (Basic) LMTC-A105

  • Block Capacity: 48 x 0.2 mL , 6 x 8 PCR Strip
  • Block Temperature Range: 4 °C - 99.9 °C
  • Temperature Accuracy: ≤ ± 0.1 °C (55 °C) ; ≤ ± 0.2 °C (≥ 90 °C)
  • Temperature Uniformity: ± 0.2 °C
  • Ramping Rate: 0.1 °C - 4 °C

Touch Screen Thermal Cycler (Basic) LMTC-A108

  • Block Temperature Range: 0 °C - 100 °C
  • Temperature Accuracy: ≤ ± 0.2 °C (35 °C - 100 °C)
  • Temperature Uniformity: ± 0.2 °C (95 °C)
  • Ramping Rate: Adjustable
  • Heating Rate: 3.5 °C/s

Touch Screen Thermal Cycler (Basic) LMTC-A100

  • Block Capacity: 16 wells x 0.2 mL
  • Block Temperature Range: 0.1 °C - 99.9 °C
  • Temperature Accuracy: ± 0.25 °C
  • Temperature Uniformity: ± 0.25 °C
  • Ramping Rate: Adjustable
Touch Screen Thermal Cycler (Basic) LMTC-A103
  • Block Capacity: 32 wells x 0.2 mL
  • Block Temperature Range: 0.1 °C - 99.9 °C
  • Temperature Accuracy: ± 0.25 °C
  • Temperature Uniformity: ± 0.25 °C
  • Ramping Rate: Adjustable
Touch Screen Thermal Cycler (Gradient) LMTC-B100
  • Block Capacity: 96 x 0.2 mL , 12 x 8 PCR Strip
  • Block Temperature Range: 4 °C - 99.9 °C
  • Temperature Accuracy: ≤ ± 0.1 °C (55 °C) ; ≤ ± 0.2 °C (≥ 90 °C)
  • Temperature Uniformity: ± 0.2 °C
  • Ramping Rate: 0.1 °C - 4 °C

Touch Screen Thermal Cycler (Basic) LMTC-A109

  • Block Temperature Range: 0 °C - 100 °C
  • Temperature Accuracy: ≤ ± 0.2 °C (35 °C - 100 °C)
  • Temperature Uniformity: ± 0.2 °C (95 °C)
  • Ramping Rate: Adjustable
  • Heating Rate: 5 °C/s

Touch Screen Thermal Cycler (Gradient) LMTC-B105

  • Block Temperature Range: 0 °C - 100 °C
  • Temperature Accuracy: ≤ ± 0.2 °C (35 °C - 100 °C)
  • Temperature Uniformity: ± 0.2 °C (95 °C)
  • Ramping Rate: Adjustable
  • Heating Rate: 3.5 °C/s

Touch Screen Thermal Cycler (Basic) LMTC-A102

  • Block Capacity: 32 wells x 0.2 mL
  • Block Temperature Range: 4 °C - 100 °C
  • Temperature Accuracy: ± 0.25 °C
  • Temperature Uniformity: ± 0.25 °C
  • Ramping Rate: Adjustable
Touch Screen Thermal Cycler (Gradient) LMTC-B200
  • Block Capacity: 6 x 16 wells x 0.2 mL , 96 wells x 0.2 mL , 12 x 8 PCR strips
  • Block Temperature Range: 4 °C - 100 °C
  • Temperature Accuracy: 4 °C - 100 °C
  • Temperature Uniformity: ≤ ± 0.15 °C (≥ 90 °C)
  • Ramping Rate: 0.1 °C - 4 °C
Touch Screen Thermal Cycler (Gradient) LMTC-B104
  • Block Capacity: 384 wells plate
  • Block Temperature Range: 4 °C - 99.9 °C
  • Temperature Accuracy: ≤ ± 0.1 °C (55 °C) ; ≤ ± 0.2 °C (≥ 90 °C)
  • Temperature Uniformity: ± 0.2 °C
  • Ramping Rate: 0.1 °C - 4 °C