Get Quote

Contact us now to receive a detailed quotation.

Need quick help? Chat with us on WhatsApp:

WhatsApp QR Code

OR

Advanced Gradient Thermal Cycler LMAG-C401

Advanced Gradient Thermal Cycler LMAG-C401 is programmed with an Android operating system and 11 pre-installed standard program patterns. Integrated with Peltier heating units, it has an automatic tightening and closing hot lid. It supports PCR runs with 64×0.2 ml and 32×0.2 ml aluminum plates. Equipped mobile operation, Wi-Fi, and USB support offers enhanced convenience. Our Advanced Gradient Thermal Cycler LMAG-C401 performs PCR amplification and DNA analysis in molecular biology, genetic research, and diagnostics.

Catalog Send Mail Whatsapp

Specifications

Capacity 64×0.2 ml (A Block) + 32×0.2ml (B Block)
Tube 0.2 ml tube, 8 strips
Temperature Range 0 to 105 °C
Maximum. Ramp Rate 5 °C/s
Uniformity ≤ ± 0.2 °C
Accuracy ≤ ± 0.1 °C
Display Resolution 0.1 °C
Temperature Control Block/ Tube
Ramping Rate Adjustable 0.1 to 5 °C
Gradient Temperature. Range 30 to 105 °C
Gradient Type normal gradient (A block)no gradient(B block)
Gradient Spread A Block-1 to 30 °CB block -NA
Hot Lid Temperature 30 to 115 °C
Number Of Programs 20000 +(USB FLASH)
Maximum. No. Of Step 40
Maximum. No. Of Cycle 100
Increment/Decrement Time 1 Sec to 600 Sec
Increment/Decrement Temperature 0.1 to 10.0 °C
Pause Function Yes
Auto Data Protection Yes
Holding 4 °C
Touchdown Function Yes
Long PCR Function Yes
Computer Software Yes
Mobile Phone APP Yes
LCD 10.1-inch,1280×800 pels
Interface USB2.0 , WIFI
Dimensions(L×W×H) 385 × 270 × 255 mm
Weight 11 kg
Power Consumption 600 W
Power Supply 100 to 240 V AC, 50/60 Hz

Pricing

Product Price Unit Action
Advanced Gradient Thermal Cycler LMAG-C401 $ 4925 Each of 1

Features

Corrosion-free aluminum unit

Heating rate up to 5°C/s

10.1-inch touchscreen display

To-and-fro air vent system

Graphical menu interface

Adjustable settings during program

Hot lid functionality

Power-off recovery system

Experiment updates via email

USB and LAN software updates

Applications

Advanced Gradient Thermal Cycler LMAG-C401 is employed in Gene expression analysis, Pathogen detection, DNA methylation analysis, Genotyping and gene scanning, miRNA research etc.

Similar Products

Advanced Thermal Cycler (Basic) LMAT-A101

  • Block Capacity: 96 wells × 0.2 ml + 77 wells × 0.5 ml
  • Block Temperature Range: 0 ℃ to 99 ℃
  • Temperature Accuracy: ≤ ± 0.2℃
  • Temperature Uniformity: ≤ ± 0.2 ℃
  • Ramping Rate: 0.1 ℃ to 3 ℃

$ 4500 / Each of 1

Advanced Gradient Thermal Cycler LMAG-C101

  • Capacity: 96×0.2 ml
  • Tube: 0.2 ml tube,8 strips, Half skirt96 wells plate, No skirt 96 wells plate
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 5 °C/s
  • Uniformity: ≤ ± 0.2 °C

$ 4050 / Each of 1

Advanced Gradient Thermal Cycler LMAG-C501

  • Capacity: 64×0.2 ml (A Block) + 32×0.2 ml (B Block)
  • Tube: 0.2 ml tube, 8 strips
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 8 °C/s
  • Uniformity: ≤ ± 0.2 °C
Catalog
Advanced Gradient Thermal Cycler LMAG-C202
  • Capacity: 96×0.2 ml
  • Tube: 0.2ml tube, 8 strips, Half skirt96 wells plate, No skirt 96 wells plate
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 8 °C/s
  • Uniformity: ≤ ± 0.2 °C

$ 5975 / Each of 1

Advanced Gradient Thermal Cycler LMAG-C201
  • Capacity: 6×16×0.2 ml
  • Tube: 0.2ml tube, 8 strips, Half skirt96 wells plate, No skirt 96 wells plate
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 6 °C/s
  • Uniformity: ≤ ± 0.2 °C

$ 4400 / Each of 1

Advanced Gradient Thermal Cycler LMAG-C102

  • Capacity: 96×0.2 ml
  • Tube: 0.2 ml tube,8 strips, Full 96 wells plate, Half skirt96 wells plate, No skirt 96 wells plate
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 6 °C/s
  • Uniformity: ≤ ± 0.2 °C

$ 4312.5 / Pack of 1

Advanced Gradient Thermal Cycler LMAG-C402

  • Capacity: 64×0.2 ml (A Block) + 32×0.2ml (B Block)
  • Tube: 0.2 ml tube, 8 strips
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 5 °C/s
  • Uniformity: ≤ ± 0.2 °C

$ 6150 / Each of 1

Advanced Thermal Cycler (Gradient) LMAT-B201

  • Block Capacity: 96 wells × 0.2 mL + 77 wells × 0.5 mL
  • Block Temperature Range: 0 ℃ to 100 ℃
  • Temperature Accuracy: ≤ ± 0.2℃ (35 ℃ ~ 100 ℃)
  • Temperature Uniformity: ≤ ± 0.2℃
  • Ramping Rate: Adjustable

$ 4775 / Each of 1

Advanced Gradient Thermal Cycler LMAG-C301
  • Capacity: 384 well
  • Tube: 384 PCR microplate
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 5 °C/s
  • Uniformity: ≤ ± 0.2 °C

$ 4400 / Each of 1

Advanced Thermal Cycler (Basic) LMAT-A100
  • Capacity: 48 wells × 0.2 mL + 48 wells × 0.5 ml
  • Temperature Range: 0 ℃ to 99 ℃
  • Temperature Accuracy: ≤ ± 0.2℃
  • Temperature Uniformity: ≤ ± 0.2 ℃
  • Ramping Rate: 0.1 ℃ to 3 ℃

$ 4500 / Each of 1

Advanced Thermal Cycler (Gradient) LMAT-B100

  • Block Capacity: 48 wells × 0.2 ml + 48 wells × 0.5 ml
  • Block Temperature Range: 0 ℃ to 99 ℃
  • Temperature Accuracy: ≤ + 0.2 ℃
  • Temperature Uniformity: ≤ ± 0.2℃
  • Ramping Rate: 0.1℃ to 3 ℃

$ 4500 / Each of 1

Advanced Thermal Cycler (Basic) LMAT-A201

  • Block Capacity: 98 wells × 0.2 mL + 77 wells × 0.5 mL, PCR strips, In-situ plate
  • Block Temperature Range: 0 ℃ to 100 ℃
  • Temperature Accuracy: ≤ ± 0.2 ℃ (35 ℃ ~ 100 ℃)
  • Temperature Uniformity: ≤ ± 0.2 ℃
  • Ramping Rate: Adjustable

$ 4500 / Pack of 1

Advanced Thermal Cycler (Gradient) LMAT-B200

  • Block Capacity: 48 wells × 0.2 mL + 48 wells × 0.5 mL
  • Block Temperature Range: 0 ℃ to 100 ℃
  • Temperature Accuracy: ≤ ± 0.2℃ (35 ℃ ~ 100 ℃)
  • Temperature Uniformity: ≤ ± 0.2℃
  • Ramping Rate: Adjustable

$ 4912.5 / Each of 1

Advanced Thermal Cycler (Gradient) LMAT-B101
  • Block Capacity: 96 wells × 0.2 ml + 77 wells × 0.5 ml
  • Block Temperature Range: 0 ℃ to 99 ℃
  • Temperature Accuracy: ≤ ± 0.2 ℃
  • Temperature Uniformity: ≤ ± 0.2℃
  • Ramping Rate: 0.1℃ to 3 ℃

$ 4500 / Each of 1

Advanced Thermal Cycler (Basic) LMAT-A200
  • Block Capacity: 48 wells × 0.2 mL + 48 wells × 0.5 mL
  • Block Temperature Range: 0 ℃ - 100 ℃
  • Temperature Accuracy: ≤ ± 0.2 ℃ (35 ℃ ~ 100 ℃)
  • Temperature Uniformity: ≤ ± 0.2 ℃
  • Ramping Rate: Adjustable

$ 4625 / Each of 1

Frequently Asked Questions

1 What is an Advanced Gradient Thermal Cycler LMAG-C401?

An Advanced Gradient Thermal Cycler LMAG-C401 is a high-performance PCR (Polymerase Chain Reaction) apparatus designed for precise and efficient DNA amplification.

2 How does an Advanced Gradient Thermal Cycler LMAG-C401 work?

Advanced Gradient Thermal Cycler LMAG-C401 operates on the principle of Polymerase Chain Reaction (PCR), using precise thermal cycling to amplify specific DNA sequences.

3 Is Advanced Gradient Thermal Cycler LMAG-C401 for testing plant tissue samples?

Advanced Gradient Thermal Cycler LMAG-C401 is used to detect plant pathogens, study gene expression, or analyze genetic traits in crops.

4 Can Advanced Gradient Thermal Cycler LMAG-C401 be used with samples from cultured cells?

Advanced Gradient Thermal Cycler LMAG-C401 is ideal for gene expression studies, transfection verification, or mutation analysis in DNA/RNA extracted from cell lines.

5 Can Advanced Gradient Thermal Cycler LMAG-C401 be used to support pharmacogenomic testing?

Advanced Gradient Thermal Cycler LMAG-C401 amplifies genetic variants that influence drug metabolism, aiding in personalized drug therapy.

6 Can Advanced Gradient Thermal Cycler LMAG-C401 be used to study neurological diseases?

Advanced Gradient Thermal Cycler LMAG-C401 is used for detection of mutations and gene expression changes related to conditions such as Alzheimer’s, Parkinson’s, and autism.

7 Can Advanced Gradient Thermal Cycler LMAG-C401 be used to amplify ancient or degraded DNA samples?

Advanced Gradient Thermal Cycler LMAG-C401 is used in archaeogenetics to study ancient biological materials.

8 Is Advanced Gradient Thermal Cycler LMAG-C401 useful for forensic applications?

Advanced Gradient Thermal Cycler LMAG-C401 amplifies trace DNA from forensic evidence such as hair, saliva, or bloodstains for identity verification and criminal investigations.

9 Can Advanced Gradient Thermal Cycler LMAG-C401 be used to validate CRISPR edits?

Advanced Gradient Thermal Cycler LMAG-C401is used to amplify and sequence target regions to confirm successful genome editing.

10 What kind of maintenance does Advanced Gradient Thermal Cycler LMAG-C401 require?

Routine maintenance includes regular cleaning, lid inspection, proper ventilation, and periodic calibration.

11 Can Advanced Thermal Cycler be used for DNA damage and repair studies?

It is used in DNA damage and repair studies to amplify damaged or repaired sequences and analyze repair pathway activity.

12 What is an Advanced Thermal Cycler?

An Advanced Thermal Cycler is a laboratory apparatus designed to amplify DNA segments by precisely controlling the temperature cycles required for polymerase chain reaction (PCR).

13 How does Advanced Thermal Cycler work?

It works by rapidly heating and cooling samples through programmed temperature steps, allowing DNA denaturation, annealing, and extension to occur during PCR.

14 How does Advanced Thermal Cycler support forensic DNA analysis?

It supports forensic DNA analysis by amplifying trace amounts of DNA from crime scene evidence for identification purposes.

15 How is Advanced Thermal Cycler applied in clinical diagnostics?

It is applied in clinical diagnostics to detect genetic disorders, infectious diseases, and cancer biomarkers through PCR-based tests.

16 Can Advanced Thermal Cycler be used in food safety testing?

It is used in food safety testing to detect bacterial contamination, allergens, and genetically modified organisms (GMOs).

17 Can Advanced Thermal Cycler be used in pharmacogenomics research in the lab?

It is used in pharmacogenomics to analyze genetic variations that affect drug metabolism and response, supporting personalized medicine.

18 How does Advanced Thermal Cycler support high-throughput screening in the lab?

It supports high-throughput screening by enabling simultaneous PCR amplification of multiple targets across 96- or 384-well plates.

19 Can Advanced Thermal Cycler be used for detecting antibiotic resistance genes in the lab?

It is used to amplify and detect antibiotic resistance genes in bacterial isolates through targeted PCR assays.

20 What role does Advanced Thermal Cycler play in metagenomic sample preparation?

It is used in metagenomics to amplify target microbial DNA from environmental or clinical samples prior to sequencing or analysis.