Labmate Water Testing Equipment measures pH levels from 2 to 20 and turbidity from 0 to 2000 NTU. They are designed with multiple sensors for real-time monitoring of water quality. Their robust design allows for continuous testing in diverse environments. They offer easy integration with monitoring systems for consistent data collection. Our Water Testing Equipment is ideal for water treatment facilities and environmental monitoring settings.

Chlorine Meter LMCLM-A100

  • Cl Measurement Range: 5 × 10⁶ to 1 M, 1.8 to 35500 ppm
  • Cl Measurement Accuracy: ± 0.5 % F.S.
  • Resolution: 0.001, 0.01, 0.1, 1
  • Temperature Measurement Range: 0 to 105 °C, 32 to 221 °F
  • Temperature Accuracy: ± 0.5 °C, ± 0.9 °F

Calcium Meter LMCAM-A100

  • Ca Measurement Range: 5 × 10⁷ to 1 M, 0.02 to 4000 ppm
  • Ca Measurement Accuracy: ± 0.5 % F.S.
  • Resolution: 0.001, 0.01, 0.1, 1
  • Temperature Measurement Range: 0 to 105 °C, 32 to 221 °F
  • Temperature Accuracy: ± 0.5 °C, ± 0.9 °F
Sodium Meter LMSDM-A100
  • Na Measurement Range: 1 × 10⁵ to 1 M, 0.1 to 23000 ppm
  • Na Measurement Accuracy: ± 0.5 % F.S.
  • Resolution: 0.001, 0.01, 0.1, 1
  • Temperature Measurement Range: 0 to 105 °C, 32 to 221 °F
  • Temperature Accuracy: ± 0.5 °C, ± 0.9 °F
Bromine Meter LMBRM-A100
  • Br Measurement Range: 5 × 10⁵ to 1 M, 0.4 to 79900 ppm
  • Br Measurement Accuracy: ± 0.5 % F.S.
  • Resolution: 0.001, 0.01, 0.1, 1
  • Temperature Measurement Range: 0 to 105 °C, 32 to 221 °F
  • Temperature Accuracy: ± 0.5 °C, ± 0.9 °F

Fluoride Meter LMFEM-A100

  • F Measurement Range: 1 × 10⁶M to saturation, 0.02 ppm to saturation
  • F Measurement Accuracy: ± 0.5 % F.S.
  • Resolution: 0.001, 0.01, 0.1, 1
  • Temperature Measurement Range: 0 to 105 °C, 32 to 221 °F
  • Temperature Accuracy: ± 0.5 °C, ± 0.9 °F

Ammonium Meter LMAMM-A100

  • NH4 Measurement Range: 5 × 10⁶ to 1 M, 0.1 to 18000 ppm
  • NH4 Measurement Accuracy: ± 0.5 % F.S.
  • Resolution: 0.001, 0.01, 0.1, 1
  • Temperature Measurement Range: 0 to 105 °C, 32 to 221 °F
  • Temperature Accuracy: ± 0.5 °C, ± 0.9 °F
Ammonia Meter LMANM-A100
  • NH3 Measurement Range: 1 × 10⁶ to1 M, 0.02 to 17000 ppm
  • NH3 Measurement Accuracy: ± 1 % F.S.
  • Resolution: 0.001, 0.01, 0.1, 1
  • Temperature Measurement Range: 0 to 105 °C, 32 to 221 °F
  • Temperature Accuracy: ± 0.5 °C, ± 0.9 °F
Cyanide Meter LMCNM-A100
  • Cn Measurement Range: 5 × 10⁶ to 0.01 M, 0.2 to 260 ppm
  • Cn Measurement Accuracy: ± 1 % F.S.
  • Resolution: 0.001, 0.01, 0.1, 1
  • Temperature Measurement Range: 0 to 105 °C, 32 to 221 °F
  • Temperature Accuracy: ± 0.5 °C, ± 0.9 °F

Potassium Meter LMPSM-A100

  • K Measurement Range: 1×10⁶ to 1M, 0.04 to 39000 ppm
  • K Measurement Accuracy: ± 1 % F.S.
  • Resolution: 0.001, 0.01, 0.1, 1
  • Temperature Measurement Range: 0 to 105 °C, 32 to 221 °F
  • Temperature Accuracy: ± 0.5 °C, ± 0.9 °F

Sulphide Ion Meter LMSPM-A100

  • S Measurement Range: 1 × 10⁷ to 1 M, 0.003 to 32100 ppm
  • S Measurement Accuracy: ± 1 % F.S.
  • Resolution: 0.001, 0.01, 0.1, 1
  • Temperature Measurement Range: 0 to 105 °C, 32 to 221 °F
  • Temperature Accuracy: ± 0.5 °C, ± 0.9 °F
Silver Ion Meter LMSIM-A100
  • Ag Measurement Range: 1 × 10⁷ to 1 M, 0.01 to 107900 ppm
  • Ag Measurement Accuracy: ± 1 % F.S.
  • Resolution: 0.001, 0.01, 0.1, 1
  • Temperature Measurement Range: 0 to 105 °C, 32 to 221 °F
  • Temperature Accuracy: ± 0.5 °C, ± 0.9 °F
Cadmium Ion Meter LMCDM-A100
  • Cd Measurement Range: 1×10⁶ to 1M, 0.01 to 11200 ppm
  • Cd Measurement Accuracy: ± 1 % F.S.
  • Resolution: 0.001, 0.01, 0.1, 1
  • Temperature Measurement Range: 0 to 105 °C, 32 to 221 °F
  • Temperature Accuracy: ± 0.5 °C, ± 0.9 °F

Lead Meter LMLDM-A100

  • Pb Measurement Range: 1×10⁸ to 0.1M, 0.2 to 20700 ppm
  • Pb Measurement Accuracy: ± 1 % F.S.
  • Resolution: 0.001, 0.01, 0.1, 1
  • Temperature Measurement Range: 0 to 105 °C, 32 to 221 °F
  • Temperature Accuracy: ± 0.5 °C, ± 0.9 °F

Copper Ion Meter LMCPM-A100

  • Cu Measurement Range: 1×10⁸ to 1M, 0.06 to 6400 ppm
  • Cu Measurement Accuracy: ± 1 % F.S.
  • Resolution: 0.001, 0.01, 0.1, 1
  • Temperature Measurement Range: 0 to 105 °C, 32 to 221 °F
  • Temperature Accuracy: ± 0.5 °C, ± 0.9 °F
Iodine Meter LMIDM-A100
  • I Measurement Range: 1×10⁸ to 1M, 0.06 to 127000 ppm
  • I Measurement Accuracy: ± 1 % F.S.
  • Resolution: 0.001, 0.01, 0.1, 1
  • Temperature Measurement Range: 0 to 105 °C, 32 to 221 °F
  • Temperature Accuracy: ± 0.5 °C, ± 0.9 °F
Fluoride Meter LMFEM-C100
  • Measuring Concentration Range: 0 to 19990 g/L
  • Temperature Range: -10 °C to 110.0°C
  • Temperature Resolution: 0.1°C
  • Temperature Accuracy: 0.1°C
  • Ambient Temperature: 5°C to 35°C

Bench Top pH Meter LMBP-401

  • pH: -2.000 - 20.000 pH, 0.001, 0.01, selectable, ±0.002 pH, 1 to 5 points, USA, NIST, DIN, 5 custom buffers
  • ORP: ±2000.0 mV, ±2000.0 mV, 0.1 mV, ±0.1 mV, 1 point
  • Temperature: 0 - 105°C/32 - 221°F, 0.1°C/0.1°F, ±0.5°C/±0.9°F, 1 point, reading ±10°C
  • Temperature Compensation: 0 - 100°C, manual or automatic
  • Solution Temperature Coefficient: 25°C

Bench Top pH Meter LMBP-402

  • pH: -2.000 - 20.000 pH, 0.001, 0.01, selectable, ±0.002 pH, 1 to 5 points, USA, NIST, DIN, 5 custom buffers
  • ORP: ±2000.0 mV, 0.1 mV, ±0.1 mV
  • Temperature: 0 - 105°C/32 - 221°F, 0.1°C/0.1°F, ±0.5°C/±0.9°F, 1 point, reading ±10°C
  • Temperature Compensation: 0 - 100°C, manual or automatic
  • Hold Function: Manual or auto-endpoint
Bench Top pH Meter LMBP-403
  • pH: -2.000 - 20.000 pH, 0.001, 0.01, selectable, ±0.002 pH, 1 to 5 points, USA, NIST, DIN, 2 custom buffers
  • ORP: ±1999.9 mV, ±1999.9 mV, 0.1 mV, ±0.1, 1 mV selectable, 1 point
  • Temperature: 0 - 105°C/32 - 221°F, 0.1°C/0.1°F, ±0.5°C/±0.9°F, 1 point, reading ±10°C
  • Temperature Compensation: 0 - 100°C, manual or automatic
  • Solution Temperature Coefficient: 25°C
Bench Top pH Meter LMBP-404
  • pH: -2.000 - 20.000 pH, 0.001, 0.01, selectable, ±0.002 pH, 1 to 5 points, USA, NIST, DIN, 2 custom buffers
  • Ion: 0.001 – 19999, 0.001, 0.01, 0.1, 1, ±0.5% F.S (monovalent), ±1% F.S.(divalent), Ppm, mg/L, moI/L, mmoI/L, 2 to 5 points, 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000
  • ORP: ±1999.9 mV, ±1999.9 mV, 0.1, 1mV selectable, ±0.2 mV, 1 point
  • Range: 0 - 105°C/32 - 221°F
  • Resolution: 0.1°C/0.1°F

Benchtop Water Hardness Meter LMBHM-401

  • Concentration Measurement Range: 0.05 to 200 mmol/L
  • CaCO3 Measurement Range: 0 to 19999 mg/L
  • CaO Measurement Range: 0 to 11220 mg/L
  • Boiler Measurement Range: 0 to 400mmol/L
  • Ca2+ Measurement Range: 0 to 8020 mg/L

Benchtop Conductivity Meter LMCMB-403

  • Conductivity Range: 0.000 μS/cm to 199.9 mS/cm
  • Conductivity Resolution: 0.001 μS/cm
  • Conductivity Accuracy: ±0.5 % FS
  • Resistivity Range: 5.00 Ω.cm to 20.00 MΩ.cm
  • Resistivity Resolution: 0.01 Ω.cm
Benchtop Conductivity Meter LMCMB-402
  • Conductivity Range: 0.00 μS/cm to 100 mS/cm
  • Conductivity Resolution: 0.01 μS/cm
  • Conductivity Accuracy: ±0.01 FS
  • TDS Range: 0.000 mg/L to 1999 mg/L
  • TDS Resolution: 0.001 mg/L
Benchtop Conductivity Meter LMCMB-401
  • Conductivity Range: 0.00 μS/cm to 100 mS/cm
  • Conductivity Resolution: 0.01 μS/cm
  • Conductivity Accuracy: ±0.01 (FS)
  • Power Supply: 100 V to 240 V (50/60Hz)
  • Dimension: 300×220×90 mm

Benchtop Conductivity Meter LMCMB-404

  • Conductivity Range: 0.055 μS/cm to 199.9 mS/cm
  • Conductivity Resolution: 0.001 μS/cm
  • Conductivity Accuracy: ±0.5 % FS
  • Resistivity Range: 5.00 Ω.cm to 18.25 MΩ.cm
  • Resistivity Resolution: 0.01 Ω.cm

Benchtop Conductivity Meter LMCMB-405

  • Conductivity Range: 0.000 μS/cm to 3000 mS/cm
  • Conductivity Resolution: 0.001 μS/cm
  • Conductivity Accuracy: ±0.5 % FS
  • Resistivity Range: 5.00 Ω.cm to 100 MΩ.cm
  • Resistivity Resolution: 0.01 Ω.cm
Benchtop Conductivity Meter LMCMB-406
  • Conductivity mode: 0 to 20.0, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm, ±1% F.S., 0.001, 0.01, 0.1, 1 automatic, 10 µS, 84 µS, 1413 µS, 12.88 mS, 111.8mS, 1, 2, 3 points
  • TDS: 0 to 10.00, 100.0, 1000 ppm, 10.00, 200.0 ppt, 0.01, 0.1, 1 automatic, ±1% F.S., 0.1 to 1.0 (default 0.5)
  • Temperature: 0 to 105°C/32 to 221°F, 0.1°C/°F, ±1°C/±1.8°F, 1 point, Reading ±10°C/°F
  • Others: 0 to 100°C/32 to 221°F, manual or automatic, 0.0 to 9.9%/°C, 25°C, K=0.1/1/10/Custom, Manual/Auto-read measurement endpoint, Custom LCD (135 × 75 mm), 6-pin mini-DIN, 3.5mm jack socket, 9V DC power adapter, 220V, 50Hz, 210×205×75mm, 1.5kg
Benchtop Dissolved Oxygen Meter LMBDO-A100
  • Dissolved oxygen range: 0.0 to 20.0 mg / L (or ppm)
  • Dissolved oxygen accuracy: ± 0.5 mg / L
  • Temperature compensation range: 0 to 40 °C, 32 to 104 °F
  • Resolution: 0.1 mg / L
  • Barometric pressure correction: 60.0 to 112.5 kPa, 450 to 850 mmHg

Benchtop Turbidity Meter LMBTM-401

  • Turbidity Range: 0 to 2000 NTU, 0 to 500 EBC, 0 to 9999 ASBC
  • Turbidity Resolution: 0.01 (0 to 99 NTU), 0.1 (100 to 999 NTU), 1 (1000 to 2000 NTU)
  • Turbidity Accuracy: ±2% of reading (0 to 500 NTU), ±3% of reading (501 to 2000 NTU)
  • Calibration Points: 2 to 7 points
  • Calibration Standards: 0.02, 10, 200, 500, 1000, 1500, 2000 NTU

Dissolved Oxygen Meter LMOM-301

  • Dissolved Oxygen Range: 0.0 to 20.0mg/L or ppm
  • Dissolved Oxygen Resolution: 0.1 mg/L
  • Dissolved Oxygen Accuracy: ±2.0%
  • % Saturation Range: 0.0 to 200.0%
  • % Saturation Resolution: 0.001
Portable Dissolved Oxygen Meter LMPOM-302
  • Dissolved Oxygen: 0.00 to 20.00 mg/L, 0.0 to 200.0% saturation, 0.01 mg/L, 0.1%, ±0.5 mg/L, ±2.0% saturation
  • Calibration Points: 1 or 2 points
  • Temperature Compensation: 0 to 50°C/32 to 122°F, automatic
  • Pressure Correction: 60.0 to 112.5kPa/450 to 850 mm Hg, manual
  • Salinity Correction: 0.0 to 50.0g/L, manual
Portable Dissolved Oxygen Meter LMPOM-303
  • Dissolved Oxygen: 0.00 to 20.00 mg/L, 0.0 to 200.0% saturation, 0.01, 0.1 mg/L..,0.1, 1% saturation, ±0.2 mg/L, ±2.0% saturation
  • Calibration Points: 1 or 2 points
  • Temperature Compensation: 0 to 50°C/32 to 122°F, automatic
  • Pressure Correction: 60.0 to 112.5kPa/450 to 850 mm Hg, manual
  • Salinity Correction: 0.0 to 50.0g/L, manual

Pen Type conductivity meter LMPTC-401

  • Range: 0 μS/cm to 2000 mS/cm
  • Resolutions: 1 μS/cm
  • Power Supply: AA battery

Pen Type conductivity meter LMPTC-403

  • Display: LCD
  • Measurement Range: 0 to 20.00 ms/cm
  • Measurement Accuracy: ±2 % FS
  • Temperature Compensation: 0 °C to 50 °C
  • Type Of Electrode: platinum black electrode
Pen Type conductivity meter LMPTC-402
  • Display: LCD
  • Measurement Range: 0 to 2000 μs/cm
  • Measurement Accuracy: ±2 % FS
  • Temperature Compensation: 0 °C to 50 °C
  • Type Of Electrode: platinum black electrode
Photometer LMPTR-100
  • Wavelength Range: 430 nm IF Δλ = 5 nm530 nm IF Δλ = 5 nm560 nm IF Δλ = 5 nm580 nm IF Δλ = 5 nm610 nm IF Δλ = 6 nm660 nm IF Δλ = 5 nm
  • Optics: LEDs, interference filters (IF), and photo sensors in transparent sample chamber
  • Wavelength Accuracy: ± 1 nm
  • Photometric Accuracy: 2 % FS (T = 20 °C to 25 °C)
  • Suitable Vials: Multi vial 10 mmRound Cuvettes 13 mmRound Cuvettes 16 mmRound Cuvettes 24 mm

Portable Conductivity Meter LMCMP-401

  • Range: 0 μS/cm to 100 mS/cm
  • Resolutions: 1 μS/cm
  • Power Supply: AA battery
  • Dimensions: 170×70×30 mm
  • Weight: 0.3 kg

Portable Conductivity Meter LMCMP-403

  • Conductivity Range: 0.000 μS/cm to 1000.0 mS/cm
  • Conductivity Resolution: 0.001 μS/cm
  • Conductivity Accuracy: ±1.0 % FS
  • Resistivity Range: 5.00 Ω.cm to 100.0 MΩ.cm
  • Resistivity Resolution: 0.01 Ω cm
Portable Conductivity Meter LMCMP-402
  • Conductivity Range: 0.000 μS/cm to 199.9 mS/cm
  • Conductivity Resolution: 0.001 μS/cm
  • Conductivity Accuracy: ±1.0 % FS
  • TDS Range: 0.000 mg/L to 19.99 g/L
  • TDS Resolution: 0.001 mg/L
Portable Conductivity Meter LMCMP-404
  • Conductivity Range: 0.000 μS/cm to 3000.0 mS/cm
  • Conductivity Resolution: 0.001 μS/cm
  • Conductivity Accuracy: ±0.5 % FS
  • Resistivity Range: 5.00 Ω.cm to 100.0 MΩ.cm
  • Resistivity Resolution: 0.01 Ω.cm

Portable Conductivity Meter LMCMP-405

  • Display: LCD
  • Measurement Range: 0.00 to 19.99μS/cm、 20.0 to 199.9μS/cm、 200 to 1999μS/cm、 2.00 to 9.99 mS/cm, 10.0 to 100.0 mS/cm
  • Measurement Accuracy: 0.5 % (F. S)
  • Temperature Compensation: 0 °C to 60 °C
  • Type of Electrode: platinum black electrode

Portable Conductivity Meter LMCMP-406

  • Display: LCD
  • Measurement Range: 0.00 to 19.99μS/cm、 20.0 to 199.9μS/cm、 200 to 1999μS/cm、 2.00 to 9.99 mS/cm, 10.0 to 100.0 mS/cm
  • Measurement Accuracy: 0.5 % (F. S)
  • Temperature Compensation: 0 °C to 50 °C
  • Type of Electrode: platinum black electrode
Portable pH Meter LMPH-401
  • pH: -2.00 - 20.00 pH, 0.01pH, , 1 to 3 points, USA (4.01/7.00/10.01), NIST (4.01/6.86/9.18)
  • ORP: ±1999mV, 1 mV, ±1 mV
  • Temperature: 0 - 105°C/32 - 221°F, 0.1°C/0.1°F, ±0.5°C/±0.9°F, 1 point, reading ±10°C
  • Temperature Compensation: 0 - 100°C, manual or automatic
  • Slope/Offset Display: Yes
Portable pH Meter LMPH-403
  • pH: -2.000 - 20.000 pH, 0.001, 0.01, 0.1pH, selectable, ±0.002pH, 1 to 5 points, USA, NIST, DIN, 2 custom buffers
  • Ion: 0.001~19999 (depending on the range of ISE), 0.001, 0.01, 0.1, 1, ±0.5% F.S. (monovalent), ±1% F.S. (divalent), ppm, mg/L, mol/L, mmol/L, 2 to 5 points, 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000
  • ORP: ±1999.9mV, ±1999.9mV, 0.1, 1mV, selectable, ±0.2mV, 1 point
  • Temperature: 0 - 105°C/32 - 221°F, 0.1°C/0.1°F, ±0.5°C/±0.9°F, 1 point, reading ±10°C
  • Temperature Compensation: 0 - 100°C, manual or automatic

Portable pH Meter LMPH-402

  • pH: -2.00 - 20.000 pH, 0.001, 0.01, 0.1pH, selectable, ±0.002pH, 1 to 5 points, USA, NIST, DIN, 2 custom buffers
  • ORP: ±1999.9mV, ±1999.9mV, 0.1, 1mV, selectable, ±0.2mV, 1 point
  • Temperature: 0 - 105°C/32 - 221°F, 0.1°C/0.1°F, ±0.5°C/±0.9°F, 1 point, reading ±10°C
  • Temperature Compensation: 0~100°C, manual or automatic
  • Stability Criteria: Low or high

Portable Turbidity Meter LMPTM-502

  • Range: 0 to 20 NTU 20 to 200 NTU 200 to 1000 NTU
  • Resolution: 0.01NTU 0.1NTU 1NTU
  • Accuracy: ±2% of reading+0.02NTU
  • Repeatability: ≤0.5%
  • Fluctuation: ±0.5% FS/30min
Portable Turbidity Meter LMPTM-501
  • Range: 0 to 1100 NTU, 0 to 275 EBC, 0 to 9999 ASBC
  • Resolution: 0.01 (0 to 99 NTU), 0.1 (100 to 999 NTU), 1 (1000 to 1100 NTU)
  • Accuracy: ±2% of reading (0 to 500 NTU), ±3% of reading (501 to 1100 NTU)
  • Calibration Points: 2 to 5 points
  • Calibration Standards: 0.02, 10, 200, 500, 1000 NTU
Portable Water Hardness Meter LMPHM-601
  • Range (Concentration): 0.05 to 200mmol/L
  • Range (German Degree): 0 to 1122°dH
  • Range (English Degree): 0 to 1404°e
  • Range (French Degree): 0 to 2000°fH
  • Range (CaCO3): 0 to 19999 mg/L

Benchtop Turbidity Meter LMBTM-402

  • Measurement Range: 0 to 50 NTU50.01 to 200 NTU200.1 to 2000 NTU2001 to 4000 NTU
  • Sample Volume: 30 to 40 ml
  • Light Source: 6V, 10W / Tungsten halogen lamp
  • Receiving Element: Silicon photocell
  • Readings Display: LCD Touch Screen

Bench Top pH Meter LMBP-500

  • pH Range: 0.00 to 14.00 pH
  • pH Accuracy: ± 0.05 pH
  • Resolution: 0.01 pH
  • Calibration Points: 2 points
  • Temperature Compensation: 0 to 100 °C, manual
Bench Top pH Meter LMBP-501
  • pH Range: 0.00 to 14.00 pH
  • pH Accuracy: ± 0.01 pH
  • Resolution: 0.01 pH
  • Calibration Points: 2 points
  • Temperature Compensation: 0 to 100 °C, manual or automatic
Bench Top pH Meter LMBP-502
  • pH Range: - 1.00 to 15.00 pH
  • pH Accuracy: ± 0.01 pH
  • Resolution: 0.01 pH
  • Calibration Points: 1to 3 points
  • Temperature Compensation: 0 to 100 °C, 32 to 212° F manual or automatic

Benchtop Conductivity Meter LMCMB-407

  • Conductivity Range: 0 to 3000 mS/cm
  • Conductivity Resolution: 0.001 μS/cm
  • Conductivity Accuracy: ±0.05
  • Calibration Point: Up to 5
  • Calibration Reminder: Yes

Water Activity Meter LMWAM-A100

  • Range: 0 to 1.0 aw
  • Accuracy: ±0.03 aw
  • Sampling Time: Max. 10 minutes (Measured value is recorded when difference between two readings is less than 0.01 aw)
  • Operating Temperature Range: 0 to 50°C
  • Operating Humidity: 95%
Salinity Meter LMSAM-A100
  • Salinity Measuring Range: 0 to 50 ppt
  • Salinity Resolution: 0.01 ppt
  • Salinity Accuracy: ±3%±1
  • Temperature Measuring Range: 0 to 60℃
  • Temperature Resolution: 0.1℃
Water Activity Meter with Sensor LMWAM-B100
  • Measuring Range: 0 to 0.980 Aw
  • Measuring Temperature Range: 0 to 50℃
  • Water Activity Accuracy: ±0.015 at 20ºC
  • Temperature Accuracy: ±0.5℃
  • Repeatability: Less than or equal to 0.015

Frequently Asked Questions

What is a Water Testing Equipment?

+

A Water Testing Equipment is an apparatus designed to analyze the physical, chemical and biological characteristics of water in order to assess its quality.

Why is Water Testing important?

+

It is crucial in identifying contaminants such as pathogens, pollutants or toxic chemicals that can harm human beings, wildlife and environment.

What parameters can be studied using Water Testing Equipment?

+

It measures parameters such as pH, conductivity, dissolved oxygen, turbidity, chlorine levels, hardness and heavy metals.

Can Water Testing Equipment help with wastewater treatment?

+

It is widely used in wastewater treatment facilities to monitor parameters such as pH, Chemical Oxygen Demand (COD) and Biological Oxygen Demand (BOD).