Gradient Thermal Cycler LMGT-B203

Gradient thermal cycler LMGT-B203 enabled with Peltier heating units which can process more than 99 cycles. It can accommodate 60×0.5 ml sample in wells. User-friendly programming is achieved via 5.7inch LCD with graphical display and windows operations system. This device can be applied across a temperature range of 0 to 99.9 °C with maximum ramping rate is 4.5°C/s.

Catalog Send Mail Whatsapp

Specifications

Capacity 60×0.5 ml
Temperature Range 0 to 99.9 °C
Maximum. Heating Rate 4.5 °C/s
Maximum. Cooling Rate 4 °C/s
Uniformity ≤ ± 0.3 °C
Accuracy ≤ ± 0.2 °C
Display Resolution 0.1 °C
Temperature Control Block\Tube
Ramping Rate Adjustable 0.1 to 4.5 °C
Gradient Uniformity ≤ ± 0.3 °C
Gradient Accuracy ≤ ± 0.2 °C
Gradient Temperature. Range 30 to 99.9 °C
Gradient Spread 1 to 30 °C
Hot Lid Temperature 30 to 110 °C
Hot Lid Height Adjustable Step less Adjustable
Number Of Programs 200
Maximum .No.Of Segment 9
Maximum. No. Of Step 9
Maximum. No. Of Cycle 99
Increment/Decrement Time 1 Second to 9 Min 59 Second
Increment/Decrement Temperature 0.1 to 9.9 °C
Pause Function Yes
Auto Data Protection Yes
Graphical Display Yes
Holding 4 °C
LCD 5.7-inch, 320×240 pels
Dimensions(L×W×H) 392×262×252 mm
Weight 10 kg
Power Consumption 600 W
Power Supply 85 to 264 V AC , 50 to 60 Hz

Pricing

Product Price Unit Action
Gradient Thermal Cycler LMGT-B203 $ 3712.5 Pack of 1

Features

Uniform heating of the samples is achieved with Peltier heating units with more than 99 cycles
Maximum. heating Rate is 4.5 °C/s with temperature range of 0 to 99.9 °C
It has the capability to accommodate 96×0.2 ml, 96×0.2 ml+77×0.5 ml with moveable hot lid which can fit different sizes of tubes
All the operations are controlled by a computer software system which instrument PCR protocols
It has power of operation recovery option which helps in continuing the same command after a recovering from power cut
To satisfy the customers need it is installed with special feature like the user can add commands while the process is going on to encounter different variations

Applications

Used in Gene expression analysis, Pathogen detection, DNA methylation analysis, Genotyping and gene scanning, miRNA research etc.

Similar Products

Gradient Thermal Cycler LMGT-A102

  • Capacity: 96×0.2ml
  • Gradient Temperature Range: 30 to 105℃
  • Gradient Set Span: Maximum 42℃
  • Gradient Temperature Accuracy: ±0.3℃
  • Gradient Temperature Uniformity: ±0.3℃

$ 4487.5 / Each of 1

Gradient Thermal Cycler LMGT-C102

  • Capacity: 96×0.2 ml
  • Gradient Temperature: 1 to 36°C
  • Ramp Rate: 4°C/s
  • Block Temperature Range: 4 to 99.9°C
  • Temperature Uniformity: ±0.3℃

$ 3106.25 / Each of 1

Gradient Thermal Cycler LMGT-A101

  • Capacity: 96×0.2ml
  • Gradient Temperature Range: 30 to 105℃
  • Maximum. Heating Rate: 5℃ /s
  • Heating Lid Temperature Range: 30℃ to 110℃
  • Maximum. Cooling Rate: 4.5℃ /s

$ 3375 / Pack of 1

Gradient Thermal Cycler LMGT-B103
  • Capacity: 60×0.5 ml
  • Temperature Range: 0 to 100 °C
  • Maximum. Heating Rate: 4.5 °C/s
  • Maximum. Cooling Rate: 4 °C/s
  • Uniformity: ≤ ± 0.2 °C

$ 3437.5 / Pack of 1

Gradient Thermal Cycler LMGT-C100
  • Capacity: 96×0.2 ml
  • Gradient Temperature: 1 to 36°C
  • Ramp Rate: 5.5°C/s
  • Block Temperature Range: 4 to 99.9°C
  • Temperature Uniformity: ±0.2℃

$ 4593.75 / Each of 1

Gradient Thermal Cycler LMGT-C200

  • Capacity: 96×0.2ml (0.2ml PCR tubes, 8-tube strips)
  • Gradient Temperature Range: 30 to 105℃
  • Gradient Setting Range: 0.1 to 30℃
  • Gradient Temperature Uniformity: Less than or equal to ±0.2℃
  • Gradient Temperature Accuracy: Less than or equal to ±0.2℃

$ 3281.25 / Each of 1

Gradient Thermal Cycler LMGT-A100

  • Capacity: 32 × 0.2 ml (microtubes), 4 × 8 × 0.2 ml (tube strips)
  • Gradient Temperature Range: 30℃ to105℃
  • Maximum. Heating Rate: 5℃/s
  • Heating Lid Temperature Range: 30℃ to110℃
  • Maximum. Cooling Rate: 4℃/s

$ 3112.5 / Pack of 1

Gradient Thermal Cycler LMGT-B102

  • Capacity: 96×0.2 ml+77×0.5 ml
  • Temperature Range: 0 to 100 °C
  • Maximum. Heating Rate: 4.5 °C/s
  • Maximum. Cooling Rate: 4 °C/s
  • Uniformity: ≤ ± 0.2 °C

$ 3612.5 / Pack of 1

Gradient Thermal Cycler LMGT-C101
  • Capacity: 96×0.2 ml
  • Gradient Temperature: 1 to 36°C
  • Ramp Rate: 5°C/s
  • Block Temperature Range: 4 to 99.9°C
  • Temperature Uniformity: ±0.2℃

$ 3593.75 / Each of 1

Gradient Thermal Cycler LMGT-B301
  • Capacity: 96×0.2 ml(6 independent 16 well block)
  • Temperature Range: 4 to 100 °C
  • Maximum. Heating Rate: 6 °C/s
  • Maximum. Cooling Rate: 4 °C/s
  • Uniformity: ≤ ± 0.3 °C

$ 4225 / Pack of 1

Gradient Thermal Cycler LMGT-B101

  • Capacity: 96×0.2 ml
  • Temperature Range: 0 to 100 °C
  • Maximum. Heating Rate: 4.5 °C/s
  • Maximum. Cooling Rate: 4 °C/s
  • Uniformity: ≤ ± 0.2 °C

$ 3612.5 / Pack of 1

Gradient Thermal Cycler LMGT-B202

  • Capacity: 96×0.2 ml+77×0.5 ml
  • Temperature Range: 0 to 99.9 °C
  • Maximum. Heating Rate: 4.5 °C/s
  • Maximum. Cooling Rate: 4 °C/s
  • Uniformity: ≤ ± 0.3 °C

$ 3712.5 / Pack of 1

Gradient Thermal Cycler LMGT-B201

  • Capacity: 96×0.2 ml
  • Temperature Range: 0 to 99.9 °C
  • Maximum. Heating Rate: 4.5 °C/s
  • Maximum. Cooling Rate: 4 °C/s
  • Uniformity: ≤ ± 0.3 °C

$ 3712.5 / Pack of 1

Gradient Thermal Cycler LMGT-B104
  • Capacity: 384 well
  • Temperature Range: 0 to 100 °C
  • Maximum. Heating Rate: 4.5 °C/s
  • Maximum. Cooling Rate: 4 °C/s
  • Uniformity: ≤ ± 0.2 °C

$ 3787.5 / Pack of 1

Frequently Asked Questions

1 What is a Gradient Thermal Cycler LMGT-B203?

A Gradient Thermal Cycler LMGT-B203 is a PCR machine that allows the precise control of temperature to help optimize DNA testing and amplification.

2 How does a Gradient Thermal Cycler LMGT-B203 work?

Gradient Thermal Cycler LMGT-B203 operates on the principle of thermal cycling, using precise temperature changes to enable DNA denaturation, primer annealing, and extension during PCR.

3 What samples can be tested using Gradient Thermal Cycler LMGT-B203?

Gradient Thermal Cycler LMGT-B203 tests DNA or RNA samples extracted from sources like blood, saliva, plant material, or microorganisms for genetic analysis and amplification.

4 Does Gradient Thermal Cycler LMGT-B203 support autoimmune disease research?

Gradient Thermal Cycler LMGT-B203 amplifies genetic markers associated with autoimmune conditions for diagnostic studies.

5 Can Gradient Thermal Cycler LMGT-B203 assist in cancer diagnostics?

Gradient Thermal Cycler LMGT-B203 amplifies tumor DNA for mutation analysis and biomarker detection.

6 Can Gradient Thermal Cycler LMGT-B203 be used in pharmaceutical manufacturing?

Gradient Thermal Cycler LMGT-B203 used for quality control and validation by amplifying genetic material during drug development.

7 Is Gradient Thermal Cycler LMGT-B203 suitable for miRNA research?

Gradient Thermal Cycler LMGT-B203 is used to amplify miRNA sequences for gene regulation studies.

8 Does Gradient Thermal Cycler LMGT-B203 support pathogen detection in environmental samples?

Gradient Thermal Cycler LMGT-B203 amplifies DNA/RNA from environmental sources to detect pathogens.

9 Is Gradient Thermal Cycler LMGT-B203 useful for pathogen typing and strain differentiation?

Gradient Thermal Cycler LMGT-B203 enables detailed identification of pathogen strains through specific DNA amplification.

10 Is Gradient Thermal Cycler LMGT-B203 suitable for transplant compatibility testing?

Gradient Thermal Cycler LMGT-B203 helps amplify and analyze HLA genes for matching donors and recipients.

11 What kind of maintenance does Advanced Gradient Thermal Cycler LMGT-B203 require?

Routine maintenance includes surface cleaning the vent dusting, lid pressure checks, and occasionally calibration.

12 What is a Gradient Thermal Cycler?

A Gradient Thermal Cycler is a PCR machine designed for simultaneous testing of different annealing temperatures across a temperature gradient.

13 How does Gradient Thermal Cycler work?

It works by creating a temperature gradient across the block, enabling multiple PCR reactions to be run at slightly different temperatures in the same cycle.

14 Can Gradient Thermal Cycler be used for multiplex PCR?

It is ideal for multiplex PCR, as it helps determine a temperature that works efficiently for multiple primer sets in the same reaction.

15 How does Gradient Thermal Cycler improve PCR efficiency in research labs?

It improves PCR efficiency in research labs by reducing trial-and-error cycles and enabling faster optimization of reaction conditions.

16 Is Gradient Thermal Cycler useful in genotyping applications?

It is widely used in genotyping to optimize conditions for amplifying specific alleles or polymorphisms accurately.

17 How does Gradient Thermal Cycler support environmental DNA (eDNA) analysis?

It supports eDNA analysis by enabling rapid optimization of PCR conditions for complex, low-abundance DNA targets in environmental samples.

18 Is Gradient Thermal Cycler beneficial for forensic DNA analysis?

It is highly beneficial for forensic DNA analysis, where precise optimization is required to amplify minute or degraded DNA samples reliably.

19 How does Gradient Thermal Cycler support microbiome or metagenomics studies?

It supports microbiome and metagenomics studies by enabling precise amplification of complex microbial DNA mixtures with optimized conditions.

20 Can Gradient Thermal Cycler be used for pathogen detection in food safety testing?

It is commonly used in food safety testing to optimize PCR conditions for detecting bacterial, viral, or fungal pathogens in food samples.

21 How does Gradient Thermal Cycler support molecular diagnostics in clinical labs?

It supports molecular diagnostics by allowing rapid and accurate PCR optimization for disease-specific genetic markers.