Get Quote

Contact us now to receive a detailed quotation.

Touch Screen Thermal Cycler (Basic) LMTC-A104

Catalog Send Mail Whatsapp

Specifications

Block Capacity 30 x 0.5 mL , 40 x 0.2 mL , 4 x 12 PCR Strip
Block Temperature Range 4 °C - 99.9 °C
Temperature Accuracy ≤ ± 0.1 °C (55 °C) ; ≤ ± 0.2 °C (≥ 90 °C)
Temperature Uniformity ± 0.2 °C
Ramping Rate 0.1 °C - 4 °C
Heating Rate 2.8 °C/s
Cooling Rate 2.8 °C/s
Hot-lid Temperature Range 30 °C - 110 °C
Max No. of Program More than 250
Max No. of Cycles 99
Increment / Decrement Time 0 - 9 min 59 sec (Long PCR)
Increment / Decrement Temperature 0.1 °C - 9.9 °C (Touchdown PCR)
Display 6.5” LCD Color Touch Screen
Data Output Port LAN
Power Consumption 600 W
Power Supply AC 110 V / 220 V ± 10 %; 50 / 60 Hz
Gross Weight 12.5 Kg

Features

Touch Screen for smooth operation Real time observation on 6.5” LCD color display Peltier based heating and cooling control SOAK function helps maintain annealing temperature Stepless adjustable Hot-lid to avoid evaporation Auto shut off when temperature is ˂ 30 °C or after cycle Auto pause / start during technical errors Block / Tube temperature control mode

Similar Products

Touch Screen Thermal Cycler (Basic) LMTC-A101

  • Block Capacity: 16 wells x 0.2 mL
  • Block Temperature Range: 4 °C - 100 °C
  • Temperature Accuracy: ± 0.25 °C
  • Temperature Uniformity: ± 0.25 °C
  • Ramping Rate: Adjustable

Touch Screen Thermal Cycler (Basic) LMTC-A200

  • Capacity: 96
  • Reaction Volume: 10 to 200ul
  • Tube Type: 96×0.2ml PCR plate, 8×0.2ml PCR tube
  • Block Temperature Range: 4°C to 105°C
  • Heat Lid Temperature Rangs: 30°C to 110°C

Touch Screen Thermal Cycler (Gradient) LMTC-B106

  • Block Temperature Range: 0 °C - 100 °C
  • Temperature Accuracy: ≤ ± 0.2 °C (35 °C - 100 °C)
  • Temperature Uniformity: ± 0.2 °C (95 °C)
  • Ramping Rate: Adjustable
  • Heating Rate: 3.5 °C/s
Touch Screen Thermal Cycler (Gradient) LMTC-B102
  • Block Capacity: 96 x 0.2 mL , 12 x 8 PCR Strip
  • Block Temperature Range: 4 °C - 99.9 °C
  • Temperature Accuracy: ≤ ± 0.1 °C (50 °C) ; ≤ ± 0.15 °C (≥ 95 °C) ; ≤ ± 0.15 °C (≥ 72 °C)
  • Temperature Uniformity: ± 0.2 °C
  • Ramping Rate: 0.1 °C - 4 °C
Touch Screen Thermal Cycler (Basic) LMTC-A107
  • Block Temperature Range: 0 °C - 100 °C
  • Temperature Accuracy: ≤ ± 0.2 °C (35 °C - 100 °C)
  • Temperature Uniformity: ± 0.2 °C (95 °C)
  • Ramping Rate: Adjustable
  • Heating Rate: 3.5 °C/s

Touch Screen Thermal Cycler (Gradient) LMTC-B104

  • Block Capacity: 384 wells plate
  • Block Temperature Range: 4 °C - 99.9 °C
  • Temperature Accuracy: ≤ ± 0.1 °C (55 °C) ; ≤ ± 0.2 °C (≥ 90 °C)
  • Temperature Uniformity: ± 0.2 °C
  • Ramping Rate: 0.1 °C - 4 °C

Touch Screen Thermal Cycler (Basic) LMTC-A102

  • Block Capacity: 32 wells x 0.2 mL
  • Block Temperature Range: 4 °C - 100 °C
  • Temperature Accuracy: ± 0.25 °C
  • Temperature Uniformity: ± 0.25 °C
  • Ramping Rate: Adjustable

Touch Screen Thermal Cycler (Gradient) LMTC-B103

  • Block Capacity: 96 x 0.2 mL , 12 x 8 PCR Strip
  • Block Temperature Range: 4 °C - 99.9 °C
  • Temperature Accuracy: ≤ ± 0.1 °C (50 °C) ; ≤ ± 0.2 °C (≥ 90 °C)
  • Temperature Uniformity: ± 0.3 °C
  • Ramping Rate: 0.1 °C - 4 °C
Touch Screen Thermal Cycler (Basic) LMTC-A100
  • Block Capacity: 16 wells x 0.2 mL
  • Block Temperature Range: 0.1 °C - 99.9 °C
  • Temperature Accuracy: ± 0.25 °C
  • Temperature Uniformity: ± 0.25 °C
  • Ramping Rate: Adjustable
Touch Screen Thermal Cycler (Basic) LMTC-A105
  • Block Capacity: 48 x 0.2 mL , 6 x 8 PCR Strip
  • Block Temperature Range: 4 °C - 99.9 °C
  • Temperature Accuracy: ≤ ± 0.1 °C (55 °C) ; ≤ ± 0.2 °C (≥ 90 °C)
  • Temperature Uniformity: ± 0.2 °C
  • Ramping Rate: 0.1 °C - 4 °C

Touch Screen Thermal Cycler (Gradient) LMTC-B100

  • Block Capacity: 96 x 0.2 mL , 12 x 8 PCR Strip
  • Block Temperature Range: 4 °C - 99.9 °C
  • Temperature Accuracy: ≤ ± 0.1 °C (55 °C) ; ≤ ± 0.2 °C (≥ 90 °C)
  • Temperature Uniformity: ± 0.2 °C
  • Ramping Rate: 0.1 °C - 4 °C

Touch Screen Thermal Cycler (Basic) LMTC-A103

  • Block Capacity: 32 wells x 0.2 mL
  • Block Temperature Range: 0.1 °C - 99.9 °C
  • Temperature Accuracy: ± 0.25 °C
  • Temperature Uniformity: ± 0.25 °C
  • Ramping Rate: Adjustable

Touch Screen Thermal Cycler (Gradient) LMTC-B101

  • Block Capacity: 96 x 0.2 mL , 12 x 8 PCR Strip
  • Block Temperature Range: 4 °C - 99.9 °C
  • Temperature Accuracy: ≤ ± 0.1 °C (50 °C) ; ≤ ± 0.2 °C (≥ 90 °C)
  • Temperature Uniformity: ± 0.2 °C
  • Ramping Rate: 0.1 °C - 4 °C
Touch Screen Thermal Cycler (Gradient) LMTC-B200
  • Block Capacity: 6 x 16 wells x 0.2 mL , 96 wells x 0.2 mL , 12 x 8 PCR strips
  • Block Temperature Range: 4 °C - 100 °C
  • Temperature Accuracy: 4 °C - 100 °C
  • Temperature Uniformity: ≤ ± 0.15 °C (≥ 90 °C)
  • Ramping Rate: 0.1 °C - 4 °C
Touch Screen Thermal Cycler (Basic) LMTC-A109
  • Block Temperature Range: 0 °C - 100 °C
  • Temperature Accuracy: ≤ ± 0.2 °C (35 °C - 100 °C)
  • Temperature Uniformity: ± 0.2 °C (95 °C)
  • Ramping Rate: Adjustable
  • Heating Rate: 5 °C/s

Frequently Asked Questions

1 What is a Touch Screen Thermal Cycler (Basic) LMTC-A104?

A Touch Screen Thermal Cycler (Basic) LMTC-A104 is a device designed for efficient and precise thermal cycling in PCR (Polymerase Chain Reaction) applications.

2 How does a Touch Screen Thermal Cycler (Basic) LMTC-A104 work?

A Touch Screen Thermal Cycler (Basic) LMTC-A104 works on the principle of thermal cycling to amplify DNA through repeated heating and cooling cycles.

3 Can Touch Screen Thermal Cycler (Basic) LMTC-A104 be used for gene expression analysis?

Touch Screen Thermal Cycler (Basic) LMTC-A104 is suitable for gene expression studies using PCR-based methods.

4 Can Touch Screen Thermal Cycler (Basic) LMTC-A104 be used for microbial DNA from bacteria or fungi?

Touch Screen Thermal Cycler (Basic) LMTC-A104 supports PCR amplification of microbial DNA from bacteria, fungi, and other microorganisms.

5 Does Touch Screen Thermal Cycler (Basic) LMTC-A104 work with ancient or degraded DNA samples?

Touch Screen Thermal Cycler (Basic) LMTC-A104 is used to amplify low-quality or degraded DNA samples.

6 Is Touch Screen Thermal Cycler (Basic) LMTC-A104 applicable for genetic analysis of algae used in biofuel industries?

Touch Screen Thermal Cycler (Basic) LMTC-A104 amplifies algal DNA for research in biofuel production and industrial applications.

7 Does Touch Screen Thermal Cycler (Basic) LMTC-A104 work with DNA extracted from biofilms in industrial pipelines?

Touch Screen Thermal Cycler (Basic) LMTC-A104 is used to amplify microbial DNA from biofilm samples in industrial settings.

8 Can Touch Screen Thermal Cycler (Basic) LMTC-A104 amplify microbial DNA involved in biodegradation processes in industrial waste?

Touch Screen Thermal Cycler (Basic) LMTC-A104 supports PCR amplification of microbes involved in biodegradation of pollutants in industrial waste.

9 Does Touch Screen Thermal Cycler (Basic) LMTC-A104 work for PCR testing of genetically modified organisms (GMOs) in industrial crops?

Touch Screen Thermal Cycler (Basic) LMTC-A104 supports GMO detection through targeted DNA amplification in industrial agriculture.

10 What kind of maintenance does Touch Screen Thermal Cycler (Basic) LMTC-A104 require?

Routine maintenance includes regular cleaning of the block and exterior, periodic calibration checks, and proper storage to ensure accurate temperature control.

11 What is a Touch Screen Thermal Cycler?

A Touch Screen Thermal Cycler is an apparatus designed with a user-friendly touch screen interface for easy programming and temperature control.

12 How does Touch Screen Thermal Cycler work?

It works by cycling through precise temperature changes needed for DNA denaturation, annealing, and extension, controlled via a user-friendly touch screen display.

13 How is Touch Screen Thermal Cycler used in genetic testing?

It is used in genetic testing to amplify specific DNA sequences, enabling the detection of genetic mutations and hereditary conditions.

14 How does Touch Screen Thermal Cycler support forensic DNA analysis?

It supports forensic DNA analysis by providing accurate and reproducible DNA amplification from trace biological evidence.

15 How does Touch Screen Thermal Cycler aid in agricultural biotechnology?

It aids in agricultural biotechnology by enabling the detection of genetically modified organisms (GMOs) and plant pathogen diagnostics.

16 How is Touch Screen Thermal Cycler used in microbial identification?

It helps identify microbes by amplifying species-specific genes, which can then be sequenced or analyzed for identification.

17 Can Touch Screen Thermal Cycler be used in food safety testing?

It is used in food safety testing to detect foodborne pathogens like Salmonella, Listeria, and E. coli through PCR-based methods.

18 How does Touch Screen Thermal Cycler benefit clinical diagnostics?

It benefits clinical diagnostics by providing fast and reliable amplification of nucleic acids for identifying infectious diseases and genetic disorders.

19 How is Touch Screen Thermal Cycler used in vaccine development?

It is used in vaccine development to clone and amplify genes encoding antigens for further study and vaccine formulation.

20 Is Touch Screen Thermal Cycler used in water quality testing?

It is used in water quality testing to detect microbial contaminants using PCR-based assays.