Gradient thermal cycler LMGT-B103 enabled with Peltier heating units which can process more than 100 cycles and store data in the internal flash memory. It can process 60×0.5 ml sample in wells. User-friendly programming is achieved via 8-inches TFT color touch-screen with graphical display and windows operations system. This device can be applied across a temperature range of 0 to 100 °C with maximum ramping rate is 4.5 °C/s. It is advantageous to use pre-installed 11 standard protocols and secure his data using password Login method. The files can be transferred via USB, printer support.

Specifications :
Capacity 60×0.5 ml
Temperature Range 0 to 100 °C
Maximum. Heating Rate 4.5 °C/s
Maximum. Cooling Rate 4 °C/s
Uniformity ≤ ± 0.2 °C
Accuracy ≤ ± 0.1 °C
Display Resolution 0.1 °C
Temperature Control Block\Tube
Ramping Rate Adjustable 0.1 to 4.5 °C
Gradient Uniformity ≤ ± 0.2 °C
Gradient Accuracy ≤ ± 0.2 °C
Gradient Temperature. Range 30 to 100 °C
Gradient Spread 1 to 30 °C
Hot Lid Temperature 30 to 110 °C
Hot Lid Height Adjustable Step less Adjustable
Number Of Programs 10000 +(USB FLASH)
Maximum. No. Of Step 30
Maximum. No. Of Cycle 100
Increment/Decrement Time 1 Second to 600 Second
Increment/Decrement Temperature 0.1 to 10.0 °C
Pause Function Yes
Auto Data Protection Yes
Holding 4 °C
Print Yes
LAN To Computer Yes
LCD 8 inch,800×600 pels, 260000 colors
Interface USB2.0 , LAN
Dimensions(L×W×H) 390×270×255mm
Weight 8.5 kg
Power Consumption 600 W
Power Supply 85 to 264 VAC , 47 to 63Hz
Features :
  • -  Uniform heating with 3 different temperature of the samples is achieved with Peltier heating units with more than 100 cycles
  • -  It is well built with anodizing technology with aluminum block treatment which makes the durable and corrosion resistant
  • -  Maximum heating rate is 4.5 °C/s with temperature range of 0 to 100 °C
  • -  It has the capability to accommodate 96×0.2ml+77×0.5ml with moveable hot lid which can fit different sizes of tubes
  • -  It has the internal flash memory to store the 10000 files data for analysis
  • -  The connectivity between computer is via USB port and mini printer and can store the GLP data after every step to get reliable results
  • -  All the operations are controlled by a computer software system which instrument PCR protocols and also has in built 11 standard protocols
  • -  It has power of operation recovery option which helps in continuing the same command after a recovering from power cut
  • -  The user can access to his individual experimental data by setting a password and data management system
  • -  To satisfy the customers need it is installed with special feature like the user can add sample while the process is going on to encounter different variations
  • -  The user will be sent notifications via email about the process to alert when operation ends
Applications :

Used in Gene expression analysis, Pathogen detection, DNA methylation analysis, Genotyping and gene scanning, miRNA research etc