Labmate Spectrophotometer offers wide wavelength ranges and high-resolution optical systems for precise wavelength selection. These are equipped with reliable photodetectors and versatile measurement modes and deliver accurate results. They are integrated with a user-friendly interface to ensure seamless analysis and data management. They are compatible with various standards and offer automatic calibration and connectivity for streamlined operation.

Micro-Spectrophotometer LMMS-801

  • Light Path: 1 mm, 0.05 mm
  • Sample Volume Requirements: 1 to 2μL
  • Light Source: Xenon Lamp
  • Detector: 2048-element linear silicide CCD array
  • Detection Range: 200 to 850 nm

Micro Spectrophotometer LMMS-802

  • Optical Path: l/0.5/0.05 mm automatic conversion
  • Optical Range: 190-1100 nm
  • Sample Volume: 0.3-2.0 µl
  • Light Source: Long life xenon lamp
  • Detector: 3864 linear CCD array
Single Beam UV/Visible Spectrophotometer LMUS-C100
  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 1 nm
  • Optical System: Single Beam, grating (1200 lines/minute)
  • Wavelength Accuracy: ± 0.3 nm
  • Wavelength Repeatability: ≤ 0.2 nm
Single Beam UV/Visible Spectrophotometer LMUS-C102
  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Single Beam, grating (1200 lines/minute)
  • Wavelength Accuracy: ± 0.5 nm
  • Wavelength Repeatability: ≤ 0.2 nm

Single Beam UV/Visible Spectrophotometer LMUS-C104

  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 0.5, 1, 2, 4, 5 nm
  • Optical System: Single Beam, grating (1200 lines/minute)
  • Wavelength Accuracy: ± 0.3 nm
  • Wavelength Repeatability: ≤ 0.2 nm

Single Beam Visible Spectrophotometer LMSV-A203

  • Wavelength: 320 nm – 1100 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Single Beam, grating (1200 lines/minute)
  • Wavelength Accuracy: ± 0.5 nm
  • Wavelength Repeatability: ≤ 0.2 nm
Single Beam Visible Spectrophotometer LMSV-A204
  • Wavelength: 320 nm – 1100 nm
  • Spectral Bandwidth: 4 nm
  • Optical System: Single Beam, grating (1200 lines/minute)
  • Wavelength Accuracy: ± 0.5 nm
  • Wavelength Repeatability: ≤ 0.2 nm
Single Beam Visible Spectrophotometer LMSV-A100
  • Wavelength: 320 nm – 1020 nm
  • Spectral Bandwidth: 4 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: 2 nm
  • Wavelength Repeatability: 1 nm

Single Beam Visible Spectrophotometer LMSV-A201

  • Wavelength: 320 nm – 1100 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: 0.3 nm
  • Wavelength Repeatability: 0.2 nm

Single Beam Visible Spectrophotometer LMSV-A202

  • Wavelength: 320 nm – 1100 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ± 0.5 nm
  • Wavelength Repeatability: ≤ 0.1 nm
Single Beam Visible Spectrophotometer LMSV-A205
  • Wavelength: 320 nm – 1100 nm
  • Spectral Bandwidth: 4 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: 2 nm
  • Wavelength Repeatability: 1 nm
Single Beam Visible Spectrophotometer LMSV-A300
  • Wavelength: 360 nm – 1000 nm
  • Spectral Bandwidth: 4 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: 1 nm
  • Wavelength Repeatability: ≤ 0.2 nm

Single Beam Visible Spectrophotometer LMSV-A301

  • Wavelength: 360 nm – 1020 nm
  • Spectral Bandwidth: 5 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ± 2 nm
  • Wavelength Repeatability: 1 nm

Single Beam Visible Spectrophotometer LMSV-A302

  • Wavelength: 360 nm – 1020 nm
  • Spectral Bandwidth: 6 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ± 3 nm
  • Wavelength Repeatability: 1 nm
NIR Spectrophotometer LMNIR-A100
  • Temperature Requirement: 5 to 35℃
  • Humidity Requirement: 5 to 85% RH
  • Analysis Time: 1 minute or above
  • Wavelength Range: 900 nm to 2500 nm
  • Wavelength Accuracy: ≤ 0.2
Atomic Absorption Spectrophotometer LMAAS-A100
  • WL Range: 190 to 900 nm
  • WL Accuracy: 0.5 nm
  • Spectrum Bandwidth: 0.2nm, 0.4nm, 0.7nm,1.4nm,2.4nm,5.0nm
  • Resolution: <40%
  • Base line stability: 0.004Abs/30min

Atomic Absorption Spectrophotometer LMAAS-A101

  • Wavelength range: 190 to 900 nm
  • Light source: Cathode lamp
  • Lamp holder: 8-lamp turret automatically rotates and aligns
  • Lamp current range: 0 to 15 mA
  • Optical system: Czerny-Turner monochromator

Atomic Absorption Spectrophotometer LMAAS-A102

  • Spectral range: 190 to 900 nm
  • Spectral bandwidth: 0.1 nm
    0.2 nm
    0.4 nm
    1.0 nm
    2.0 nm
  • Wavelength accuracy: ± 0.15 nm
  • Wavelength repeatability: ≤ 0.04 nm
  • Baseline stability: ≤ 0.002 Abs / 30 min
Split Beam UV-Vis Spectrophotometer LMUS-D100
  • Display: 7-inch color touchscreen
  • Spectral Band Width: 2 nm
  • Optical System: Split Beam
  • Wavelength Range: 190 to 1100 nm
  • Photometric Range: 0.0 to 200.0%T
    -0.301 to 4.000 A
    0.000 to 9999 C
Flame Absorption Spectrophotometer LMFAS-A100
  • Wavelength Range: 190 nm to 900 nm
  • Wavelength Accuracy: ± 0.25 nm
  • Wavelength Repeatability: 0.15 nm
  • Spectral Bandwidth: 0.1 nm
    0.2 nm
    1.0 nm
    2.0 nm
  • Temperature: 15 °C to 30 °C

Double Beam UV/Visible Spectrophotometer LMUD-A101

  • Wavelength: 190 nm to 1100 nm
  • Spectral Bandwidth: 1 nm
  • Optical System: Double Beam, grating (1200 lines/minute)
  • Wavelength Accuracy: ± 0.3 nm
  • Wavelength Repeatability: ≤ 0.2 nm

Single Beam UV/Visible Spectrophotometer LMUS-A200

  • Wavelength: 195 nm – 1020 nm
  • Spectral Bandwidth: 5 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ± 2 nm
  • Wavelength Repeatability: 1 nm
Single Beam UV/Visible Spectrophotometer LMUS-A300
  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 1 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: 0.5 nm
  • Wavelength Repeatability: 0.2 nm
Single Beam UV/Visible Spectrophotometer LMUS-A301
  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 1.8 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ± 0.5 nm
  • Wavelength Repeatability: ≤ 0.2 nm

Single Beam UV/Visible Spectrophotometer LMUS-A302

  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 1.8 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: 0.3 nm
  • Wavelength Repeatability: 0.1 nm

Single Beam UV/Visible Spectrophotometer LMUS-A303

  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ± 0.5 nm
  • Wavelength Repeatability: ≤ 0.2 nm
Single Beam UV/Visible Spectrophotometer LMUS-A304
  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ± 0.8 nm
  • Wavelength Repeatability: ≤ 0.3 nm
Single Beam UV/Visible Spectrophotometer LMUS-A305
  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: 1 nm
  • Wavelength Repeatability: ≤ 0.5 nm

Single Beam UV/Visible Spectrophotometer LMUS-A306

  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: 1 nm
  • Wavelength Repeatability: ≤ 0.2 nm

Single Beam UV/Visible Spectrophotometer LMUS-A307

  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: 2 nm
  • Wavelength Repeatability: 1 nm
Single Beam UV/Visible Spectrophotometer LMUS-A308
  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 4 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ± 1 nm
  • Wavelength Repeatability: ≤ 0.3 nm
Single Beam UV/Visible Spectrophotometer LMUS-A309
  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 4 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: 1 nm
  • Wavelength Repeatability: ≤ 0.5 nm

Single Beam UV/Visible Spectrophotometer LMUS-A310

  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 4 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: 2 nm
  • Wavelength Repeatability: 1nm

Single Beam UV/Visible Spectrophotometer LMUS-A311

  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 0.5 / 1 / 2 / 4 / 5 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: 0.3 nm
  • Wavelength Repeatability: 0.1 nm
Single Beam UV/Visible Spectrophotometer LMUS-B100
  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 1 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ± 0.3 nm
  • Wavelength Repeatability: ≤ 0.1 nm
Single Beam UV/Visible Spectrophotometer LMUS-B101
  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ± 0.3 nm
  • Wavelength Repeatability: ≤ 0.1 nm

Single Beam UV/Visible Spectrophotometer LMUS-B102

  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 0.5 / 1 / 2 / 4 / 5 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ± 0.3 nm
  • Wavelength Repeatability: ≤ 0.1 nm

Single Beam UV/Visible Spectrophotometer LMUS-C101

  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 1 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ± 0.3 nm
  • Wavelength Repeatability: ≤ 0.1 nm
Single Beam UV/Visible Spectrophotometer LMUS-C103
  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ± 0.3 nm
  • Wavelength Repeatability: ≤ 0.1 nm
Single Beam UV/Visible Spectrophotometer LMUS-C105
  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 0.5 / 1 / 2 / 4 / 5 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ± 0.3 nm
  • Wavelength Repeatability: ≤ 0.1 nm

Single Beam UV/Visible Spectrophotometer LMUS-A100

  • Wavelength: 190 nm – 1020 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: 2 nm
  • Wavelength Repeatability: 1 nm

Single Beam UV/Visible Spectrophotometer LMUS-A101

  • Wavelength: 190 nm – 1020 nm
  • Spectral Bandwidth: 4 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: 2 nm
  • Wavelength Repeatability: 1 nm
Double Beam UV/Visible Spectrophotometer LMUD-A100
  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 1 nm
  • Optical System: Double Beam, grating (1200 lines/minute)
  • Wavelength Accuracy: 0.3 nm
  • Wavelength Repeatability: 0.1 nm
Double Beam UV/Visible Spectrophotometer LMUD-A102
  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 1.8 nm
  • Optical System: Double Beam, grating (1200 lines/minute)
  • Wavelength Accuracy: ± 0.3 nm
  • Wavelength Repeatability: ≤ 0.1 nm

Double Beam UV/Visible Spectrophotometer LMUD-A103

  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 1.8 nm
  • Optical System: Double Beam, grating (1200 lines/minute)
  • Wavelength Accuracy: ± 0.3 nm
  • Wavelength Repeatability: ≤ 0.2 nm

Double Beam UV/Visible Spectrophotometer LMUD-A104

  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Double Beam, grating (1200 lines/minute)
  • Wavelength Accuracy: 0.3 nm
  • Wavelength Repeatability: 0.1 nm
Double Beam UV/Visible Spectrophotometer LMUD-A105
  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Double Beam, grating (1200 lines/minute)
  • Wavelength Accuracy: ± 0.3 nm
  • Wavelength Repeatability: ≤ 0.2 nm
Double Beam UV/Visible Spectrophotometer LMUD-A106
  • Wavelength Range: 190~1100 nm
  • Spectral Bandwidth: 0.5 nm, 1.0 nm, 2.0 nm, 4.0nm
  • Optical System: Double beam
  • Wavelength Accuracy: ±0.1 nm
  • Wavelength Repeatability: ≤0.02nm

Double Beam UV/Visible Spectrophotometer LMUD-A107

  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 0.5 nm, 1 nm, 2 nm, 4 nm, 5 nm
  • Optical System: Double Beam, grating (1200 lines/minute)
  • Wavelength Accuracy: ± 0.3 nm
  • Wavelength Repeatability: ≤ 0.2 nm

Double Beam UV/Visible Spectrophotometer LMUD-B101

  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 1 nm
  • Optical System: Double Beam, grating (1200 lines/minute)
  • Wavelength Accuracy: ± 0.3 nm
  • Wavelength Repeatability: ≤ 0.1 nm
Double Beam UV/Visible Spectrophotometer LMUD-B102
  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 1 nm
  • Optical System: Double Beam, grating (1200 lines/minute)
  • Wavelength Accuracy: ± 0.3 nm
  • Wavelength Repeatability: ≤ 0.1 nm
Double Beam UV/Visible Spectrophotometer LMUD-B105
  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Double Beam, grating (1200 lines/minute)
  • Wavelength Accuracy: ± 0.3 nm
  • Wavelength Repeatability: ≤ 0.1 nm

Double Beam UV/Visible Spectrophotometer LMUD-B106

  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Double Beam, grating (1200 lines/minute)
  • Wavelength Accuracy: ± 0.3 nm
  • Wavelength Repeatability: ≤ 0.1 nm

Double Beam UV/Visible Spectrophotometer LMUD-B109

  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 0.5 nm, 1 nm, 2 nm, 4 nm, 5 nm
  • Optical System: Double Beam, grating (1200 lines/minute)
  • Wavelength Accuracy: ± 0.3 nm
  • Wavelength Repeatability: ≤ 0.1 nm
Double Beam UV/Visible Spectrophotometer LMUD-A200
  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 1 nm
  • Optical System: Double Beam, grating (1200 lines/minute)
  • Wavelength Accuracy: ± 0.3 nm
  • Wavelength Repeatability: ≤ 0.1 nm
Double Beam UV/Visible Spectrophotometer LMUD-A201
  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 1 nm
  • Optical System: Double Beam, grating (1200 lines/minute)
  • Wavelength Accuracy: ± 0.3 nm
  • Wavelength Repeatability: ≤ 0.1 nm

Double Beam UV/Visible Spectrophotometer LMUD-A202

  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 1 nm
  • Optical System: Double Beam, grating (1200 lines/minute)
  • Wavelength Accuracy: ± 0.3 nm
  • Wavelength Repeatability: ≤ 0.1 nm

Double Beam UV/Visible Spectrophotometer LMUD-A203

  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Double Beam, grating (1200 lines/minute)
  • Wavelength Accuracy: ± 0.3 nm
  • Wavelength Repeatability: ≤ 0.1 nm
Double Beam UV/Visible Spectrophotometer LMUD-A204
  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Double Beam, grating (1200 lines/minute)
  • Wavelength Accuracy: ± 0.3 nm
  • Wavelength Repeatability: ≤ 0.1 nm
Double Beam UV/Visible Spectrophotometer LMUD-A205
  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Double Beam, grating (1200 lines/minute)
  • Wavelength Accuracy: ± 0.5 nm
  • Wavelength Repeatability: ≤ 0.2 nm

Double Beam UV/Visible Spectrophotometer LMUD-A206

  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 0.5 nm, 1 nm, 2 nm, 4 nm, 5 nm
  • Optical System: Double Beam, grating (1200 lines/minute)
  • Wavelength Accuracy: ± 0.3 nm
  • Wavelength Repeatability: ≤ 0.1 nm

Micro Spectrophotometer LMMS-803

  • Wavelength Range: 190 to 850nm
  • Light Range: 0.02mm, 0.05mm (High concentration measurement)
    0.2mm, 1.0mm (General concentration measurement)
  • Light Source: Xenon flashing light
  • Absorbance Range: 0.02 to 300A
  • Absorbance Precision: 002Abs (0.2mm Light Range)
Atomic Absorption Spectrophotometer LMAAS-A103
  • Optical System: Double Beam
  • Monochromator: Czerny-Turner type, focal lengths at 350mm
  • Grating: Grating 1800 lines/mm, scintillation wavelength 250nm
  • Spectral Bandwidth: 0.1, 0.2, 0.4, 0.7, 1.4, 2 nm Automated slit selection
  • Wavelength Range: 185 to 900 nm
Fluorescence Spectrophotometer LMFSP-A100
  • Wavelength Range: 200nm to 900nm
  • Detection Sensitivity: Water Raman peak signal-to-noise ratio: S/N ≥ 150 (P-P)
  • Excitation And Emission Wavelength Bandwidth: 10nm
  • Microprocessor: PID 0 to 199.9
  • Accuracy Of Emission Wavelength: ±1.0nm

Micro Spectrophotometer LMMS-A900

  • Wavelength: 180 to 910 nm; Cuvette (OD600): 600±8 nm
  • Wavelength Accuracy: ±1 nm
  • Sample Volume: 0.5 to 2.0μl
  • Sample Pedestal: 304 Stainless Steel and Quartz Fiber
  • Spectral Resolution: ≤ 1.5 nm

Micro Spectrophotometer LMMS-A901

  • Wavelength Range: 180 to 910 nm
  • Wavelength Accuracy: ±1 nm
  • Sample Volume: 0.5μl ~ 2μl, advice 2μl
  • Spectral Resolution: ≤1.5 nm (FWHM@ Hg 253.7nm)
  • Detector: 2048-element linear CMOS array
Atomic Emission Spectrophotometer LMAES-A100
  • Spectral Range: 165 nm to 950 nm
  • Focal Length: 400 mm
  • Grating: Echelle Grating
  • Prism: Ultra-pure SiO2 material
  • Stray Light: Equivalent background concentration of 10000μg/ml Ca solution