Ask An Expert

We will Follow up with you within 24 hours.

Touch Screen Thermal Cycler (Basic) LMTC-A101

Catalog

Specifications

Block Capacity 16 wells x 0.2 mL
Block Temperature Range 4 °C - 100 °C
Temperature Accuracy ± 0.25 °C
Temperature Uniformity ± 0.25 °C
Ramping Rate Adjustable
Heating Rate 5 °C/s
Cooling Rate 4 °C/s
Display Resolution 0.1 °C
Gradient Temperature Range
Gradient Temperature Accuracy
Gradient Temperature Uniformity
Gradient Capacity
Temperature Differential Range
Hot-lid Temperature Range
Max No. of Steps
Max No. of Program More than 100
Max No. of Cycles
Increment / Decrement Time Available (Long PCR)
Increment / Decrement Temperature Available (Touchdown PCR)
Display 4.3” TFT Color Touch Screen
Data Output Port
Power Consumption 160 W
Power Supply AC 85 V / 265 V; 47 / 63 Hz
Dimension 267 x 190 x 115 mm
Net Weight 2.5 Kg
Gross Weight

Pricing

Product Price Unit Action
Touch Screen Thermal Cycler (Basic) LMTC-A101 $1,700.00 Pack of 1

Features

Touch Screen for smooth operation Real time observation on 4.3” TFT color display Peltier based heating and cooling control Adjustable Ramping rate for rapid operation Auto shut off when temperature is ˂ 30 °C or after cycle Auto pause / start during technical errors Block / Tube temperature control mode

Similar Products

Touch Screen Thermal Cycler (Gradient) LMTC-B106

  • Block Capacity:
  • Block Temperature Range: 0 °C - 100 °C
  • Temperature Accuracy: ≤ ± 0.2 °C (35 °C - 100 °C)
  • Temperature Uniformity: ± 0.2 °C (95 °C)
  • Ramping Rate: Adjustable

Touch Screen Thermal Cycler (Basic) LMTC-A102

  • Block Capacity: 32 wells x 0.2 mL
  • Block Temperature Range: 4 °C - 100 °C
  • Temperature Accuracy: ± 0.25 °C
  • Temperature Uniformity: ± 0.25 °C
  • Ramping Rate: Adjustable

Touch Screen Thermal Cycler (Gradient) LMTC-B103

  • Block Capacity: 96 x 0.2 mL , 12 x 8 PCR Strip
  • Block Temperature Range: 4 °C - 99.9 °C
  • Temperature Accuracy: ≤ ± 0.1 °C (50 °C) ; ≤ ± 0.2 °C (≥ 90 °C)
  • Temperature Uniformity: ± 0.3 °C
  • Ramping Rate: 0.1 °C - 4 °C
Touch Screen Thermal Cycler (Gradient) LMTC-B107
  • Block Capacity:
  • Block Temperature Range: 0 °C - 100 °C
  • Temperature Accuracy: ≤ ± 0.2 °C (35 °C - 100 °C)
  • Temperature Uniformity: ± 0.2 °C (95 °C)
  • Ramping Rate: Adjustable
Touch Screen Thermal Cycler (Gradient) LMTC-B100
  • Block Capacity: 96 x 0.2 mL , 12 x 8 PCR Strip
  • Block Temperature Range: 4 °C - 99.9 °C
  • Temperature Accuracy: ≤ ± 0.1 °C (55 °C) ; ≤ ± 0.2 °C (≥ 90 °C)
  • Temperature Uniformity: ± 0.2 °C
  • Ramping Rate: 0.1 °C - 4 °C

Touch Screen Thermal Cycler (Gradient) LMTC-B104

  • Block Capacity: 384 wells plate
  • Block Temperature Range: 4 °C - 99.9 °C
  • Temperature Accuracy: ≤ ± 0.1 °C (55 °C) ; ≤ ± 0.2 °C (≥ 90 °C)
  • Temperature Uniformity: ± 0.2 °C
  • Ramping Rate: 0.1 °C - 4 °C

Touch Screen Thermal Cycler (Basic) LMTC-A109

  • Block Capacity:
  • Block Temperature Range: 0 °C - 100 °C
  • Temperature Accuracy: ≤ ± 0.2 °C (35 °C - 100 °C)
  • Temperature Uniformity: ± 0.2 °C (95 °C)
  • Ramping Rate: Adjustable

Touch Screen Thermal Cycler (Basic) LMTC-A106

  • Block Capacity: 96 wells x 0.2 mL
  • Block Temperature Range: 4 °C - 99.9 °C
  • Temperature Accuracy: ≤ ± 0.1 °C (55 °C) ; ≤ ± 0.2 °C (≥ 90 °C)
  • Temperature Uniformity: ± 0.2 °C
  • Ramping Rate: 0.1 °C - 4 °C
Touch Screen Thermal Cycler (Gradient) LMTC-B101
  • Block Capacity: 96 x 0.2 mL , 12 x 8 PCR Strip
  • Block Temperature Range: 4 °C - 99.9 °C
  • Temperature Accuracy: ≤ ± 0.1 °C (50 °C) ; ≤ ± 0.2 °C (≥ 90 °C)
  • Temperature Uniformity: ± 0.2 °C
  • Ramping Rate: 0.1 °C - 4 °C
Touch Screen Thermal Cycler (Basic) LMTC-A100
  • Block Capacity: 16 wells x 0.2 mL
  • Block Temperature Range: 0.1 °C - 99.9 °C
  • Temperature Accuracy: ± 0.25 °C
  • Temperature Uniformity: ± 0.25 °C
  • Ramping Rate: Adjustable

Touch Screen Thermal Cycler (Gradient) LMTC-B108

  • Block Capacity:
  • Block Temperature Range: 0 °C - 100 °C
  • Temperature Accuracy: ≤ ± 0.2 °C (35 °C - 100 °C)
  • Temperature Uniformity: ± 0.2 °C (95 °C)
  • Ramping Rate: Adjustable

Touch Screen Thermal Cycler (Basic) LMTC-A107

  • Block Capacity:
  • Block Temperature Range: 0 °C - 100 °C
  • Temperature Accuracy: ≤ ± 0.2 °C (35 °C - 100 °C)
  • Temperature Uniformity: ± 0.2 °C (95 °C)
  • Ramping Rate: Adjustable

Touch Screen Thermal Cycler (Gradient) LMTC-B200

  • Block Capacity: 6 x 16 wells x 0.2 mL , 96 wells x 0.2 mL , 12 x 8 PCR strips
  • Block Temperature Range: 4 °C - 100 °C
  • Temperature Accuracy: 4 °C - 100 °C
  • Temperature Uniformity: ≤ ± 0.15 °C (≥ 90 °C)
  • Ramping Rate: 0.1 °C - 4 °C
Touch Screen Thermal Cycler (Basic) LMTC-A103
  • Block Capacity: 32 wells x 0.2 mL
  • Block Temperature Range: 0.1 °C - 99.9 °C
  • Temperature Accuracy: ± 0.25 °C
  • Temperature Uniformity: ± 0.25 °C
  • Ramping Rate: Adjustable
Touch Screen Thermal Cycler (Gradient) LMTC-B105
  • Block Capacity:
  • Block Temperature Range: 0 °C - 100 °C
  • Temperature Accuracy: ≤ ± 0.2 °C (35 °C - 100 °C)
  • Temperature Uniformity: ± 0.2 °C (95 °C)
  • Ramping Rate: Adjustable