Get Quote

Contact us now to receive a detailed quotation.

Advanced Thermal Cycler (Gradient) LMAT-B200

Advanced Thermal Cycler (Gradient) LMAT- B200 features wide temperature range from 0°C to 100°C. It features dual block configuration with 48 wells for 0.2 mL tubes and 48 wells for 0.5 mL tubes. Equipped with USB or LAN updates for new features and software enhancements. Incorporated touchscreen interface simplifies programming and operation. Our Advanced Thermal Cycler (Gradient) supports PCR, DNA analysis, gene expression, pathogen detection, and environmental testing.

Catalog Send Mail Whatsapp

Specifications

Block Capacity 48 wells × 0.2 mL + 48 wells × 0.5 mL
Block Temperature Range 0 ℃ to 100 ℃
Temperature Accuracy ≤ ± 0.2℃ (35 ℃ ~ 100 ℃)
Temperature Uniformity ≤ ± 0.2℃
Ramping Rate Adjustable
Heating Rate 4℃/s
Cooling Rate 3.5 ℃/s
Display Resolution 0.1℃
Gradient Temperature Range 30 ℃ to 99.9 ℃
Gradient Temperature Accuracy ≤ ± 0.3 ℃ (35 ℃ - 99.9 ℃)
Gradient Temperature Uniformity ≤ ± 0.3 ℃
Gradient Capacity 12 Columns (Vertical)
Temperature Differential Range 1℃ - 30 ℃
Hot-lid Temperature Range 30 ℃ to 105 ℃
Max No. of Steps 30
Max No. of Program 120
Max No. of Cycles 100
Increment / Decrement Time 1 to 120 sec (Long PCR)
Increment / Decrement Temperature 0.1 ℃ to 10.0 ℃ (Touchdown PCR)
Display 5.7
Data Output Port USB 2.0 / RS232 Port
Power Consumption 600 W
Power Supply AC 175 / 275 V; 50 / 60 Hz
Dimension 335 × 240 × 270 mm
Net Weight 9.8 Kg

Pricing

Product Price Unit Action
Advanced Thermal Cycler (Gradient) LMAT-B200 $ 4912.5 Each of 1

Features

Fast thermal ramping 

Android OS with programs

Compact design with air vents

Auto self-closing hot lid

Corrosion-resistant aluminum build

Adjustable settings mid-run

Power-off recovery system

Applications

Advanced Thermal Cycler (Gradient) LMAT-B200 is widely used for PCR, DNA quantification, and gene expression studies. It also supports applications like pathogen detection and environmental testing across various fields.

Similar Products

Advanced Thermal Cycler (Gradient) LMAT-B201

  • Block Capacity: 96 wells × 0.2 mL + 77 wells × 0.5 mL
  • Block Temperature Range: 0 ℃ to 100 ℃
  • Temperature Accuracy: ≤ ± 0.2℃ (35 ℃ ~ 100 ℃)
  • Temperature Uniformity: ≤ ± 0.2℃
  • Ramping Rate: Adjustable

$ 4775 / Each of 1

Advanced Gradient Thermal Cycler LMAG-C501

  • Capacity: 64×0.2 ml (A Block) + 32×0.2 ml (B Block)
  • Tube: 0.2 ml tube, 8 strips
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 8 °C/s
  • Uniformity: ≤ ± 0.2 °C

$ 800 / Each of 1

Advanced Thermal Cycler (Basic) LMAT-A201

  • Block Capacity: 98 wells × 0.2 mL + 77 wells × 0.5 mL, PCR strips, In-situ plate
  • Block Temperature Range: 0 ℃ to 100 ℃
  • Temperature Accuracy: ≤ ± 0.2 ℃ (35 ℃ ~ 100 ℃)
  • Temperature Uniformity: ≤ ± 0.2 ℃
  • Ramping Rate: Adjustable

$ 4500 / Pack of 1

Advanced Gradient Thermal Cycler LMAG-C301
  • Capacity: 384 well
  • Tube: 384 PCR microplate
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 5 °C/s
  • Uniformity: ≤ ± 0.2 °C

$ 4400 / Each of 1

Advanced Thermal Cycler (Basic) LMAT-A200
  • Block Capacity: 48 wells × 0.2 mL + 48 wells × 0.5 mL
  • Block Temperature Range: 0 ℃ - 100 ℃
  • Temperature Accuracy: ≤ ± 0.2 ℃ (35 ℃ ~ 100 ℃)
  • Temperature Uniformity: ≤ ± 0.2 ℃
  • Ramping Rate: Adjustable

$ 4625 / Each of 1

Advanced Thermal Cycler (Gradient) LMAT-B101

  • Block Capacity: 96 wells × 0.2 ml + 77 wells × 0.5 ml
  • Block Temperature Range: 0 ℃ to 99 ℃
  • Temperature Accuracy: ≤ ± 0.2 ℃
  • Temperature Uniformity: ≤ ± 0.2℃
  • Ramping Rate: 0.1℃ to 3 ℃

$ 4500 / Each of 1

Advanced Gradient Thermal Cycler LMAG-C201

  • Capacity: 6×16×0.2 ml
  • Tube: 0.2ml tube, 8 strips, Half skirt96 wells plate, No skirt 96 wells plate
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 6 °C/s
  • Uniformity: ≤ ± 0.2 °C

$ 4400 / Each of 1

Advanced Gradient Thermal Cycler LMAG-C202

  • Capacity: 96×0.2 ml
  • Tube: 0.2ml tube, 8 strips, Half skirt96 wells plate, No skirt 96 wells plate
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 8 °C/s
  • Uniformity: ≤ ± 0.2 °C

$ 5975 / Each of 1

Advanced Thermal Cycler (Basic) LMAT-A101
  • Block Capacity: 96 wells × 0.2 ml + 77 wells × 0.5 ml
  • Block Temperature Range: 0 ℃ to 99 ℃
  • Temperature Accuracy: ≤ ± 0.2℃
  • Temperature Uniformity: ≤ ± 0.2 ℃
  • Ramping Rate: 0.1 ℃ to 3 ℃

$ 4500 / Each of 1

Advanced Gradient Thermal Cycler LMAG-C401
  • Capacity: 64×0.2 ml (A Block) + 32×0.2ml (B Block)
  • Tube: 0.2 ml tube, 8 strips
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 5 °C/s
  • Uniformity: ≤ ± 0.2 °C

$ 4925 / Each of 1

Advanced Gradient Thermal Cycler LMAG-C101

  • Capacity: 96×0.2 ml
  • Tube: 0.2 ml tube,8 strips, Half skirt96 wells plate, No skirt 96 wells plate
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 5 °C/s
  • Uniformity: ≤ ± 0.2 °C

$ 4050 / Each of 1

Advanced Thermal Cycler (Gradient) LMAT-B100

  • Block Capacity: 48 wells × 0.2 ml + 48 wells × 0.5 ml
  • Block Temperature Range: 0 ℃ to 99 ℃
  • Temperature Accuracy: ≤ + 0.2 ℃
  • Temperature Uniformity: ≤ ± 0.2℃
  • Ramping Rate: 0.1℃ to 3 ℃

$ 4500 / Each of 1

Advanced Gradient Thermal Cycler LMAG-C402

  • Capacity: 64×0.2 ml (A Block) + 32×0.2ml (B Block)
  • Tube: 0.2 ml tube, 8 strips
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 5 °C/s
  • Uniformity: ≤ ± 0.2 °C

$ 6150 / Each of 1

Advanced Gradient Thermal Cycler LMAG-C102
  • Capacity: 96×0.2 ml
  • Tube: 0.2 ml tube,8 strips, Full 96 wells plate, Half skirt96 wells plate, No skirt 96 wells plate
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 6 °C/s
  • Uniformity: ≤ ± 0.2 °C

$ 4312.5 / Pack of 1

Advanced Thermal Cycler (Basic) LMAT-A100
  • Capacity: 48 wells × 0.2 mL + 48 wells × 0.5 ml
  • Temperature Range: 0 ℃ to 99 ℃
  • Temperature Accuracy: ≤ ± 0.2℃
  • Temperature Uniformity: ≤ ± 0.2 ℃
  • Ramping Rate: 0.1 ℃ to 3 ℃

$ 4500 / Each of 1

Frequently Asked Questions

1 What is an Advanced Thermal Cycler (Gradient) LMAT-B200?

An Advanced Thermal Cycler (Gradient) LMAT-B200 is a high-precision PCR machine with gradient temperature capability, designed for efficient nucleic acid amplification and molecular biology applications.

2 How does Advanced Thermal Cycler (Gradient) LMAT-B200 work?

An Advanced Thermal Cycler (Gradient) LMAT-B200 operates on the principle of thermal cycling, involving repeated heating and cooling to denature DNA, anneal primers, and extend new strands during the PCR process.

3 Can Advanced Thermal Cycler (Gradient) LMAT-B200 be used for genetic testing in human or animal tissues?

The Advanced Thermal Cycler (Gradient) LMAT-B200 amplifies DNA from tissue samples for genetic screening, disease diagnostics, or trait analysis.

4 Is Advanced Thermal Cycler (Gradient) LMAT-B200 suitable for plant DNA analysis?

Advanced Thermal Cycler (Gradient) LMAT-B200 efficiently amplifies plant genomic DNA for GMO detection, phylogenetic analysis and breeding research.

5 Can Advanced Thermal Cycler (Gradient) LMAT-B200 be used for blood-based disease detection?

Advanced Thermal Cycler (Gradient) LMAT-B200 is used to extract DNA or RNA from blood, to detect pathogens or genetic markers linked to diseases.

6 Is Advanced Thermal Cycler (Gradient) LMAT-B200 useful for detecting viral infections?

Advanced Thermal Cycler (Gradient) LMAT-B200 amplifies viral RNA or DNA to detect viruses such as influenza or COVID-19.

7 Can Advanced Thermal Cycler (Gradient) LMAT-B200 be used to analyze microbial DNA from soil or water samples?

Advanced Thermal Cycler (Gradient) LMAT-B200 is suitable for eDNA studies to detect microbial or fungal species in soil or water samples.

8 Can Advanced Thermal Cycler (Gradient) LMAT-B200 be used for detecting GMOs in food products?

Advanced Thermal Cycler (Gradient) LMAT-B200 amplifies specific DNA sequences to identify genetically modified organisms in food and agricultural products.

9 Is Advanced Thermal Cycler (Gradient) LMAT-B200 applicable for forensic DNA analysis?

Advanced Thermal Cycler (Gradient) LMAT-B200 amplifies trace DNA samples for use in forensic identification.

10 What kind of maintenance does Advanced Thermal Cycler (Gradient) LMAT-B200 require?

Regular maintenance includes cleaning the block, lid, and vents, and performing regular temperature calibration for accurate results.

11 Can Advanced Thermal Cycler be used for DNA damage and repair studies?

It is used in DNA damage and repair studies to amplify damaged or repaired sequences and analyze repair pathway activity.

12 What is an Advanced Thermal Cycler?

An Advanced Thermal Cycler is a laboratory apparatus designed to amplify DNA segments by precisely controlling the temperature cycles required for polymerase chain reaction (PCR).

13 How does Advanced Thermal Cycler work?

It works by rapidly heating and cooling samples through programmed temperature steps, allowing DNA denaturation, annealing, and extension to occur during PCR.

14 How does Advanced Thermal Cycler support forensic DNA analysis?

It supports forensic DNA analysis by amplifying trace amounts of DNA from crime scene evidence for identification purposes.

15 How is Advanced Thermal Cycler applied in clinical diagnostics?

It is applied in clinical diagnostics to detect genetic disorders, infectious diseases, and cancer biomarkers through PCR-based tests.

16 Can Advanced Thermal Cycler be used in food safety testing?

It is used in food safety testing to detect bacterial contamination, allergens, and genetically modified organisms (GMOs).

17 Can Advanced Thermal Cycler be used in pharmacogenomics research in the lab?

It is used in pharmacogenomics to analyze genetic variations that affect drug metabolism and response, supporting personalized medicine.

18 How does Advanced Thermal Cycler support high-throughput screening in the lab?

It supports high-throughput screening by enabling simultaneous PCR amplification of multiple targets across 96- or 384-well plates.

19 Can Advanced Thermal Cycler be used for detecting antibiotic resistance genes in the lab?

It is used to amplify and detect antibiotic resistance genes in bacterial isolates through targeted PCR assays.

20 What role does Advanced Thermal Cycler play in metagenomic sample preparation?

It is used in metagenomics to amplify target microbial DNA from environmental or clinical samples prior to sequencing or analysis.