Advanced Gradient Thermal Cycler LMAG-C102 operates with a maximum temperature of 105°C and has a capacity of 96 wells, each with a volume of 0.2 ml. It features a gradient spread from 1 to 42 °C for optimizing the annealing temperature of primers. Our thermal cycler can perform up to 100 cycles, ensuring high sensitivity and maximum yield. It is integrated with a 10-inch LCD for easy monitoring and controlling of parameters.
Catalog Send Mail Whatsapp

Specifications

Capacity 96×0.2 ml
Tube 0.2 ml tube,8 strips, Full 96 wells plate, Half skirt96 wells plate, No skirt 96 wells plate
Temperature Range 0 to 105 °C
Maximum. Ramp Rate 6 °C/s
Uniformity ≤ ± 0.2 °C
Accuracy ≤ ± 0.1 °C
Display Resolution 0.1 °C
Temperature Control Block /Tube
Maximum. Heating Rate Adjustable 0.1 to 6 °C
Gradient Temperature. Range 30 to 105 °C
Gradient Type Normal Gradient
Gradient Spread 1 to 42 °C
Hot Lid Temperature 30 to 115 °C
Number Of Programs 20000 +(USB FLASH)
Maximum. No. Of Step 30
Maximum. No. Of Cycle 100
Increment/Decrement Time 1 Sec to 600 Sec
Increment/Decrement Temperature 0.1 to 10.0 ℃
Pause Function Yes
Auto Data Protection Yes
Holding 4 ℃
Touchdown Function Yes
Long PCR Function Yes
Computer Software Yes
Mobile Phone APP Yes
LCD 10.1 inch,1280×800 pels
Interface USB2.0 , WIFI
Power Consumption 600 W
Power Supply 100 to 240 V AC ,50/60 Hz
Dimensions(L×W×H) 385× 270× 255 mm
Weight 10 kg

Pricing

Product Price Unit Action
Advanced Gradient Thermal Cycler LMAG-C102 $ 4312.5 Pack of 1

Features

Corrosive resistant
Equipped with peltier heating units
Automatic closing lid
Pre-installed with 11 standard program
Compatible with android operation system
Power off recovery System

Applications

Advanced Gradient Thermal Cycler is used for precise and efficient DNA amplification. It is utilized in molecular biology research, clinical diagnostics, agricultural biotechnology, forensic analysis and environmental studies.

Similar Products

Advanced Gradient Thermal Cycler LMAG-C101

  • Capacity: 96×0.2 ml
  • Tube: 0.2 ml tube,8 strips, Half skirt96 wells plate, No skirt 96 wells plate
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 5 °C/s
  • Uniformity: ≤ ± 0.2 °C

$ 4050 / Each of 1

Advanced Thermal Cycler (Gradient) LMAT-B201

  • Block Capacity: 96 wells × 0.2 mL + 77 wells × 0.5 mL
  • Block Temperature Range: 0 ℃ to 100 ℃
  • Temperature Accuracy: ≤ ± 0.2℃ (35 ℃ ~ 100 ℃)
  • Temperature Uniformity: ≤ ± 0.2℃
  • Ramping Rate: Adjustable

$ 4775 / Each of 1

Advanced Thermal Cycler (Basic) LMAT-A200

  • Block Capacity: 48 wells × 0.2 mL + 48 wells × 0.5 mL
  • Block Temperature Range: 0 ℃ - 100 ℃
  • Temperature Accuracy: ≤ ± 0.2 ℃ (35 ℃ ~ 100 ℃)
  • Temperature Uniformity: ≤ ± 0.2 ℃
  • Ramping Rate: Adjustable

$ 4625 / Each of 1

Advanced Gradient Thermal Cycler LMAG-C402
  • Capacity: 64×0.2 ml (A Block) + 32×0.2ml (B Block)
  • Tube: 0.2 ml tube, 8 strips
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 5 °C/s
  • Uniformity: ≤ ± 0.2 °C

$ 6150 / Each of 1

Advanced Gradient Thermal Cycler LMAG-C401
  • Capacity: 64×0.2 ml (A Block) + 32×0.2ml (B Block)
  • Tube: 0.2 ml tube, 8 strips
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 5 °C/s
  • Uniformity: ≤ ± 0.2 °C

$ 4925 / Each of 1

Advanced Gradient Thermal Cycler LMAG-C201

  • Capacity: 6×16×0.2 ml
  • Tube: 0.2ml tube, 8 strips, Half skirt96 wells plate, No skirt 96 wells plate
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 6 °C/s
  • Uniformity: ≤ ± 0.2 °C

$ 4400 / Each of 1

Advanced Thermal Cycler (Basic) LMAT-A100

  • Capacity: 48 wells × 0.2 mL + 48 wells × 0.5 ml
  • Temperature Range: 0 ℃ to 99 ℃
  • Temperature Accuracy: ≤ ± 0.2℃
  • Temperature Uniformity: ≤ ± 0.2 ℃
  • Ramping Rate: 0.1 ℃ to 3 ℃

$ 4500 / Each of 1

Advanced Thermal Cycler (Basic) LMAT-A101

  • Block Capacity: 96 wells × 0.2 ml + 77 wells × 0.5 ml
  • Block Temperature Range: 0 ℃ to 99 ℃
  • Temperature Accuracy: ≤ ± 0.2℃
  • Temperature Uniformity: ≤ ± 0.2 ℃
  • Ramping Rate: 0.1 ℃ to 3 ℃

$ 4500 / Each of 1

Advanced Gradient Thermal Cycler LMAG-C301
  • Capacity: 384 well
  • Tube: 384 PCR microplate
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 5 °C/s
  • Uniformity: ≤ ± 0.2 °C

$ 4400 / Each of 1

Advanced Thermal Cycler (Basic) LMAT-A201
  • Block Capacity: 98 wells × 0.2 mL + 77 wells × 0.5 mL, PCR strips, In-situ plate
  • Block Temperature Range: 0 ℃ to 100 ℃
  • Temperature Accuracy: ≤ ± 0.2 ℃ (35 ℃ ~ 100 ℃)
  • Temperature Uniformity: ≤ ± 0.2 ℃
  • Ramping Rate: Adjustable

$ 4500 / Pack of 1

Advanced Gradient Thermal Cycler LMAG-C501

  • Capacity: 64×0.2 ml (A Block) + 32×0.2 ml (B Block)
  • Tube: 0.2 ml tube, 8 strips
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 8 °C/s
  • Uniformity: ≤ ± 0.2 °C
Catalog

Advanced Thermal Cycler (Gradient) LMAT-B100

  • Block Capacity: 48 wells × 0.2 ml + 48 wells × 0.5 ml
  • Block Temperature Range: 0 ℃ to 99 ℃
  • Temperature Accuracy: ≤ + 0.2 ℃
  • Temperature Uniformity: ≤ ± 0.2℃
  • Ramping Rate: 0.1℃ to 3 ℃

$ 4500 / Each of 1

Advanced Thermal Cycler (Gradient) LMAT-B101

  • Block Capacity: 96 wells × 0.2 ml + 77 wells × 0.5 ml
  • Block Temperature Range: 0 ℃ to 99 ℃
  • Temperature Accuracy: ≤ ± 0.2 ℃
  • Temperature Uniformity: ≤ ± 0.2℃
  • Ramping Rate: 0.1℃ to 3 ℃

$ 4500 / Each of 1

Advanced Thermal Cycler (Gradient) LMAT-B200
  • Block Capacity: 48 wells × 0.2 mL + 48 wells × 0.5 mL
  • Block Temperature Range: 0 ℃ to 100 ℃
  • Temperature Accuracy: ≤ ± 0.2℃ (35 ℃ ~ 100 ℃)
  • Temperature Uniformity: ≤ ± 0.2℃
  • Ramping Rate: Adjustable

$ 4912.5 / Each of 1

Advanced Gradient Thermal Cycler LMAG-C202
  • Capacity: 96×0.2 ml
  • Tube: 0.2ml tube, 8 strips, Half skirt96 wells plate, No skirt 96 wells plate
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 8 °C/s
  • Uniformity: ≤ ± 0.2 °C

$ 5975 / Each of 1

Frequently Asked Questions

1 What is an Advanced Gradient Thermal Cycler LMAG-C102?

An Advanced Gradient Thermal Cycler LMAG-C102 is a high-performance PCR (Polymerase Chain Reaction) apparatus designed for precise and efficient DNA amplification.

2 How does an Advanced Gradient Thermal Cycler LMAG-C102 work?

An Advanced Gradient Thermal Cycler LMAG-C102 operates on the principle of Polymerase Chain Reaction (PCR), which is a technique used to amplify specific DNA sequences.

3 Is Advanced Gradient Thermal Cycler LMAG-C102 suitable for GMO detection in food products?

Advanced Gradient Thermal Cycler LMAG-C102 amplifies specific genetic markers used in GMO screening and labeling.

4 Can Advanced Gradient Thermal Cycler LMAG-C102 be used for urine and fecal samples?

Advanced Gradient Thermal Cycler LMAG-C102 amplifies nucleic acids from urine or fecal samples for clinical and microbiome analysis.

5 Can Advanced Gradient Thermal Cycler LMAG-C102 be used for pathogen detection in veterinary samples?

Advanced Gradient Thermal Cycler LMAG-C102 amplifies DNA/RNA from animal samples for diagnosing infectious diseases in veterinary medicine.

6 Can Advanced Gradient Thermal Cycler LMAG-C102 be used for DNA methylation analysis?

Advanced Gradient Thermal Cycler LMAG-C102 supports bisulfite-treated DNA amplification for epigenetic methylation studies.

7 Can Advanced Gradient Thermal Cycler LMAG-C102 assist in forensic mitochondrial DNA analysis?

Advanced Gradient Thermal Cycler LMAG-C102 amplifies mitochondrial DNA regions commonly used in forensic identification.

8 Is Advanced Gradient Thermal Cycler LMAG-C102 useful for amplification of ancient or degraded DNA samples?

Advanced Gradient Thermal Cycler LMAG-C102 has precise temperature control which helps improve DNA amplification, especially for low-quality or degraded samples.

9 Can Advanced Gradient Thermal Cycler LMAG-C102 be used for miRNA research applications?

Advanced Gradient Thermal Cycler LMAG-C102 is used for reverse transcription and PCR steps needed for miRNA quantification.

10 What kind of maintenance does Advanced Gradient Thermal Cycler LMAG-C102 require?

Routine maintenance includes regularly cleaning the block and lid to prevent contamination, as well as periodically checking and calibrating temperature accuracy periodically.

11 Can Advanced Thermal Cycler be used for DNA damage and repair studies?

It is used in DNA damage and repair studies to amplify damaged or repaired sequences and analyze repair pathway activity.

12 What is an Advanced Thermal Cycler?

An Advanced Thermal Cycler is a laboratory apparatus designed to amplify DNA segments by precisely controlling the temperature cycles required for polymerase chain reaction (PCR).

13 How does Advanced Thermal Cycler work?

It works by rapidly heating and cooling samples through programmed temperature steps, allowing DNA denaturation, annealing, and extension to occur during PCR.

14 How does Advanced Thermal Cycler support forensic DNA analysis?

It supports forensic DNA analysis by amplifying trace amounts of DNA from crime scene evidence for identification purposes.

15 How is Advanced Thermal Cycler applied in clinical diagnostics?

It is applied in clinical diagnostics to detect genetic disorders, infectious diseases, and cancer biomarkers through PCR-based tests.

16 Can Advanced Thermal Cycler be used in food safety testing?

It is used in food safety testing to detect bacterial contamination, allergens, and genetically modified organisms (GMOs).

17 Can Advanced Thermal Cycler be used in pharmacogenomics research in the lab?

It is used in pharmacogenomics to analyze genetic variations that affect drug metabolism and response, supporting personalized medicine.

18 How does Advanced Thermal Cycler support high-throughput screening in the lab?

It supports high-throughput screening by enabling simultaneous PCR amplification of multiple targets across 96- or 384-well plates.

19 Can Advanced Thermal Cycler be used for detecting antibiotic resistance genes in the lab?

It is used to amplify and detect antibiotic resistance genes in bacterial isolates through targeted PCR assays.

20 What role does Advanced Thermal Cycler play in metagenomic sample preparation?

It is used in metagenomics to amplify target microbial DNA from environmental or clinical samples prior to sequencing or analysis.