Advanced Thermal Cycler (Gradient) LMAT-B201

Advanced Thermal Cycler (Gradient) LMAT- B201 features wide temperature range from 0°C to 100°C. It features dual block configuration with 96 wells for 0.2 mL tubes and 77 wells for 0.5 mL tubes. Integrated USB or LAN updates for integrating new features and software enhancements. Equipped touchscreen interface simplifies programming and operation. Our Advanced Thermal Cycler (Gradient) supports PCR, DNA analysis, gene expression, pathogen detection, and environmental testing.

Catalog Send Mail Whatsapp

Specifications

Block Capacity 96 wells × 0.2 mL + 77 wells × 0.5 mL
Block Temperature Range 0 ℃ to 100 ℃
Temperature Accuracy ≤ ± 0.2℃ (35 ℃ ~ 100 ℃)
Temperature Uniformity ≤ ± 0.2℃
Ramping Rate Adjustable
Heating Rate 4℃/s
Cooling Rate 3.5 ℃/s
Display Resolution 0.1℃
Gradient Temperature Range 30 ℃ to 99.9 ℃
Gradient Temperature Accuracy ≤ ± 0.3 ℃ (35 ℃ - 99.9 ℃)
Gradient Temperature Uniformity ≤ ± 0.3 ℃
Gradient Capacity 12 Columns (Vertical)
Temperature Differential Range 1℃ to 30 ℃
Hot-lid Temperature Range 30 ℃ to 105 ℃
Max No. of Steps 30
Max No. of Program 120
Max No. of Cycles 100
Increment / Decrement Time 1 to 120 sec (Long PCR)
Increment / Decrement Temperature 0.1 ℃ to 10.0 ℃ (Touchdown PCR)
Display 5.7
Data Output Port USB 2.0 / RS232 Port
Power Consumption 600 W
Power Supply AC 175 / 275 V; 50 / 60 Hz
Dimension 335 × 240 × 270 mm
Net Weight 9.8 Kg

Pricing

Product Price Unit Action
Advanced Thermal Cycler (Gradient) LMAT-B201 $ 4775 Each of 1

Features

Fast thermal ramping 

Android OS with programs

Compact design with air vents

Auto self-closing hot lid

Corrosion-resistant aluminum build

Adjustable settings mid-run

Power-off recovery system

Applications

Advanced Thermal Cycler (Gradient) LMAT-B201 is widely used for PCR, DNA quantification, and gene expression studies. It also supports applications like pathogen detection and environmental testing across various fields.

Similar Products

Advanced Thermal Cycler (Basic) LMAT-A201

  • Block Capacity: 98 wells × 0.2 mL + 77 wells × 0.5 mL, PCR strips, In-situ plate
  • Block Temperature Range: 0 ℃ to 100 ℃
  • Temperature Accuracy: ≤ ± 0.2 ℃ (35 ℃ ~ 100 ℃)
  • Temperature Uniformity: ≤ ± 0.2 ℃
  • Ramping Rate: Adjustable

$ 4500 / Pack of 1

Advanced Gradient Thermal Cycler LMAG-C102

  • Capacity: 96×0.2 ml
  • Tube: 0.2 ml tube,8 strips, Full 96 wells plate, Half skirt96 wells plate, No skirt 96 wells plate
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 6 °C/s
  • Uniformity: ≤ ± 0.2 °C

$ 4312.5 / Pack of 1

Advanced Gradient Thermal Cycler LMAG-C402

  • Capacity: 64×0.2 ml (A Block) + 32×0.2ml (B Block)
  • Tube: 0.2 ml tube, 8 strips
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 5 °C/s
  • Uniformity: ≤ ± 0.2 °C

$ 6150 / Each of 1

Advanced Thermal Cycler (Basic) LMAT-A200
  • Block Capacity: 48 wells × 0.2 mL + 48 wells × 0.5 mL
  • Block Temperature Range: 0 ℃ - 100 ℃
  • Temperature Accuracy: ≤ ± 0.2 ℃ (35 ℃ ~ 100 ℃)
  • Temperature Uniformity: ≤ ± 0.2 ℃
  • Ramping Rate: Adjustable

$ 4625 / Each of 1

Advanced Thermal Cycler (Gradient) LMAT-B100
  • Block Capacity: 48 wells × 0.2 ml + 48 wells × 0.5 ml
  • Block Temperature Range: 0 ℃ to 99 ℃
  • Temperature Accuracy: ≤ + 0.2 ℃
  • Temperature Uniformity: ≤ ± 0.2℃
  • Ramping Rate: 0.1℃ to 3 ℃

$ 4500 / Each of 1

Advanced Thermal Cycler (Basic) LMAT-A101

  • Block Capacity: 96 wells × 0.2 ml + 77 wells × 0.5 ml
  • Block Temperature Range: 0 ℃ to 99 ℃
  • Temperature Accuracy: ≤ ± 0.2℃
  • Temperature Uniformity: ≤ ± 0.2 ℃
  • Ramping Rate: 0.1 ℃ to 3 ℃

$ 4500 / Each of 1

Advanced Gradient Thermal Cycler LMAG-C101

  • Capacity: 96×0.2 ml
  • Tube: 0.2 ml tube,8 strips, Half skirt96 wells plate, No skirt 96 wells plate
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 5 °C/s
  • Uniformity: ≤ ± 0.2 °C

$ 4050 / Each of 1

Advanced Gradient Thermal Cycler LMAG-C201

  • Capacity: 6×16×0.2 ml
  • Tube: 0.2ml tube, 8 strips, Half skirt96 wells plate, No skirt 96 wells plate
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 6 °C/s
  • Uniformity: ≤ ± 0.2 °C

$ 4400 / Each of 1

Advanced Gradient Thermal Cycler LMAG-C202
  • Capacity: 96×0.2 ml
  • Tube: 0.2ml tube, 8 strips, Half skirt96 wells plate, No skirt 96 wells plate
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 8 °C/s
  • Uniformity: ≤ ± 0.2 °C

$ 5975 / Each of 1

Advanced Gradient Thermal Cycler LMAG-C501
  • Capacity: 64×0.2 ml (A Block) + 32×0.2 ml (B Block)
  • Tube: 0.2 ml tube, 8 strips
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 8 °C/s
  • Uniformity: ≤ ± 0.2 °C
Catalog

Advanced Gradient Thermal Cycler LMAG-C301

  • Capacity: 384 well
  • Tube: 384 PCR microplate
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 5 °C/s
  • Uniformity: ≤ ± 0.2 °C

$ 4400 / Each of 1

Advanced Thermal Cycler (Gradient) LMAT-B200

  • Block Capacity: 48 wells × 0.2 mL + 48 wells × 0.5 mL
  • Block Temperature Range: 0 ℃ to 100 ℃
  • Temperature Accuracy: ≤ ± 0.2℃ (35 ℃ ~ 100 ℃)
  • Temperature Uniformity: ≤ ± 0.2℃
  • Ramping Rate: Adjustable

$ 4912.5 / Each of 1

Advanced Thermal Cycler (Gradient) LMAT-B101

  • Block Capacity: 96 wells × 0.2 ml + 77 wells × 0.5 ml
  • Block Temperature Range: 0 ℃ to 99 ℃
  • Temperature Accuracy: ≤ ± 0.2 ℃
  • Temperature Uniformity: ≤ ± 0.2℃
  • Ramping Rate: 0.1℃ to 3 ℃

$ 4500 / Each of 1

Advanced Gradient Thermal Cycler LMAG-C401
  • Capacity: 64×0.2 ml (A Block) + 32×0.2ml (B Block)
  • Tube: 0.2 ml tube, 8 strips
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 5 °C/s
  • Uniformity: ≤ ± 0.2 °C

$ 4925 / Each of 1

Advanced Thermal Cycler (Basic) LMAT-A100
  • Capacity: 48 wells × 0.2 mL + 48 wells × 0.5 ml
  • Temperature Range: 0 ℃ to 99 ℃
  • Temperature Accuracy: ≤ ± 0.2℃
  • Temperature Uniformity: ≤ ± 0.2 ℃
  • Ramping Rate: 0.1 ℃ to 3 ℃

$ 4500 / Each of 1

Frequently Asked Questions

1 What is an Advanced Thermal Cycler (Gradient) LMAT-B201?

An Advanced Thermal Cycler (Gradient) LMAT-B201 is a high-precision PCR machine with gradient capability for efficient DNA amplification in research and diagnostic laboratories.

2 How does Advanced Thermal Cycler (Gradient) LMAT-B201 work?

It operates on the principle of thermal cycling, where repeated heating and cooling cycles enable DNA denaturation, primer annealing, and extension during PCR.

3 Can Advanced Thermal Cycler (Gradient) LMAT-B201 be used in clinical diagnostics?

Advanced Thermal Cycler (Gradient) LMAT-B201is used for detecting genetic disorders, infectious diseases, and pathogen identification.

4 Is Advanced Thermal Cycler (Gradient) LMAT-B201 effective for microbial cultures like bacteria, viruses, or fungi?

Advanced Thermal Cycler (Gradient) LMAT-B201 amplifies genetic material from microbial samples for identification, classification, or antimicrobial resistance studies.

5 Can Advanced Thermal Cycler (Gradient) LMAT-B201 process swab samples like nasal or throat swabs?

Advanced Thermal Cycler (Gradient) LMAT-B201is used to amplify viral or bacterial RNA/DNA from swab samples, such as in COVID-19 testing.

6 Is Advanced Thermal Cycler (Gradient) LMAT-B201 useful for forensic science?

Advanced Thermal Cycler (Gradient) LMAT-B201 is used to amplify DNA from forensic samples for identification purposes.

7 Can Advanced Thermal Cycler (Gradient) LMAT-B201 be used for gene cloning experiments?

Advanced Thermal Cycler (Gradient) LMAT-B201 is ideal for amplifying gene fragments needed for cloning.

8 Can Advanced Thermal Cycler (Gradient) LMAT-B201 be used for environmental samples?

Advanced Thermal Cycler (Gradient) LMAT-B201 is used to detect microorganisms or contaminants after extracting DNA/RNA from environmental samples.

9 Can Advanced Thermal Cycler (Gradient) LMAT-B201 be used to test plant material?

Advanced Thermal Cycler (Gradient) LMAT-B201 is used in plant research for analyze genes related to traits, disease resistance, or genetic modification.

10 What kind of maintenance does Advanced Thermal Cycler (Gradient) LMAT-B201 require?

Regular maintenance includes cleaning the wells, keeping the unit well-ventilated, and performing annual calibration.

11 Can Advanced Thermal Cycler be used for DNA damage and repair studies?

It is used in DNA damage and repair studies to amplify damaged or repaired sequences and analyze repair pathway activity.

12 What is an Advanced Thermal Cycler?

An Advanced Thermal Cycler is a laboratory apparatus designed to amplify DNA segments by precisely controlling the temperature cycles required for polymerase chain reaction (PCR).

13 How does Advanced Thermal Cycler work?

It works by rapidly heating and cooling samples through programmed temperature steps, allowing DNA denaturation, annealing, and extension to occur during PCR.

14 How does Advanced Thermal Cycler support forensic DNA analysis?

It supports forensic DNA analysis by amplifying trace amounts of DNA from crime scene evidence for identification purposes.

15 How is Advanced Thermal Cycler applied in clinical diagnostics?

It is applied in clinical diagnostics to detect genetic disorders, infectious diseases, and cancer biomarkers through PCR-based tests.

16 Can Advanced Thermal Cycler be used in food safety testing?

It is used in food safety testing to detect bacterial contamination, allergens, and genetically modified organisms (GMOs).

17 Can Advanced Thermal Cycler be used in pharmacogenomics research in the lab?

It is used in pharmacogenomics to analyze genetic variations that affect drug metabolism and response, supporting personalized medicine.

18 How does Advanced Thermal Cycler support high-throughput screening in the lab?

It supports high-throughput screening by enabling simultaneous PCR amplification of multiple targets across 96- or 384-well plates.

19 Can Advanced Thermal Cycler be used for detecting antibiotic resistance genes in the lab?

It is used to amplify and detect antibiotic resistance genes in bacterial isolates through targeted PCR assays.

20 What role does Advanced Thermal Cycler play in metagenomic sample preparation?

It is used in metagenomics to amplify target microbial DNA from environmental or clinical samples prior to sequencing or analysis.