Get Quote

Contact us now to receive a detailed quotation.

Need quick help? Chat with us on WhatsApp:

WhatsApp QR Code

OR

Advanced Thermal Cycler (Basic) LMAT-A201

Advanced Thermal Cycler (Basic) LMAT-A201 features wide temperature range from 0°C to 100°C. It supports dual block configuration with 96 wells for 0.2 mL tubes and 77 wells for 0.5 mL tubes. Intuitive touchscreen interface simplifies programming and operation. Incorporating rapid heating rate of 4°C/second ensures faster cycle. Our Advanced Thermal Cycler is employed in applications such as PCR, DNA quantification, gene expression studies, pathogen detection, and environmental and agricultural testing.

Catalog Send Mail Whatsapp

Specifications

Block Capacity 98 wells × 0.2 mL + 77 wells × 0.5 mL, PCR strips, In-situ plate
Block Temperature Range 0 ℃ to 100 ℃
Temperature Accuracy ≤ ± 0.2 ℃ (35 ℃ ~ 100 ℃)
Temperature Uniformity ≤ ± 0.2 ℃
Ramping Rate Adjustable
Heating Rate 4 ℃/s
Cooling Rate 3.5 ℃/s
Display Resolution 0.1 º℃
Hot-lid Temperature Range 30 ℃ to 105 ℃
Max No. of Steps 30
Max No. of Program 120
Max No. of Cycles 100
Increment / Decrement Time 1 - 120 sec (Long PCR)
Increment / Decrement Temperature 0.1 ℃ to 10.0 ℃ (Touchdown PCR)
Display 5.7
Data Output Port USB 2.0 / RS232 Port
Power Consumption 600 W
Power Supply AC 175 / 275 V; 50 / 60 Hz
Dimension 335 × 240 × 270 mm
Net Weight 7.3 Kg
Gross Weight 10 kg

Pricing

Product Price Unit Action
Advanced Thermal Cycler (Basic) LMAT-A201 $ 4500 Pack of 1

Features

Programmable settings

Uniform temperature control

High throughput

Gradient optimization

Real-time monitoring

Data export features

Low DNA input sensitivity

Remote access support

Durable construction

Applications

Advanced Thermal Cycler (Basic) LMAT-A201 is essential in PCR, gene expression studies, and pathogen detection for amplification of DNA and RNA. It is perfect for DNA quantification, environmental testing, and agricultural research, supporting various genetic analyses and diagnostics.

Similar Products

Advanced Gradient Thermal Cycler LMAG-C202

  • Capacity: 96×0.2 ml
  • Tube: 0.2ml tube, 8 strips, Half skirt96 wells plate, No skirt 96 wells plate
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 8 °C/s
  • Uniformity: ≤ ± 0.2 °C

$ 5975 / Each of 1

Advanced Gradient Thermal Cycler LMAG-C301

  • Capacity: 384 well
  • Tube: 384 PCR microplate
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 5 °C/s
  • Uniformity: ≤ ± 0.2 °C

$ 4400 / Each of 1

Advanced Thermal Cycler (Gradient) LMAT-B201

  • Block Capacity: 96 wells × 0.2 mL + 77 wells × 0.5 mL
  • Block Temperature Range: 0 ℃ to 100 ℃
  • Temperature Accuracy: ≤ ± 0.2℃ (35 ℃ ~ 100 ℃)
  • Temperature Uniformity: ≤ ± 0.2℃
  • Ramping Rate: Adjustable

$ 4775 / Each of 1

Advanced Gradient Thermal Cycler LMAG-C401
  • Capacity: 64×0.2 ml (A Block) + 32×0.2ml (B Block)
  • Tube: 0.2 ml tube, 8 strips
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 5 °C/s
  • Uniformity: ≤ ± 0.2 °C

$ 4925 / Each of 1

Advanced Thermal Cycler (Gradient) LMAT-B100
  • Block Capacity: 48 wells × 0.2 ml + 48 wells × 0.5 ml
  • Block Temperature Range: 0 ℃ to 99 ℃
  • Temperature Accuracy: ≤ + 0.2 ℃
  • Temperature Uniformity: ≤ ± 0.2℃
  • Ramping Rate: 0.1℃ to 3 ℃

$ 4500 / Each of 1

Advanced Gradient Thermal Cycler LMAG-C402

  • Capacity: 64×0.2 ml (A Block) + 32×0.2ml (B Block)
  • Tube: 0.2 ml tube, 8 strips
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 5 °C/s
  • Uniformity: ≤ ± 0.2 °C

$ 6150 / Each of 1

Advanced Thermal Cycler (Basic) LMAT-A101

  • Block Capacity: 96 wells × 0.2 ml + 77 wells × 0.5 ml
  • Block Temperature Range: 0 ℃ to 99 ℃
  • Temperature Accuracy: ≤ ± 0.2℃
  • Temperature Uniformity: ≤ ± 0.2 ℃
  • Ramping Rate: 0.1 ℃ to 3 ℃

$ 4500 / Each of 1

Advanced Gradient Thermal Cycler LMAG-C501

  • Capacity: 64×0.2 ml (A Block) + 32×0.2 ml (B Block)
  • Tube: 0.2 ml tube, 8 strips
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 8 °C/s
  • Uniformity: ≤ ± 0.2 °C
Catalog
Advanced Thermal Cycler (Basic) LMAT-A200
  • Block Capacity: 48 wells × 0.2 mL + 48 wells × 0.5 mL
  • Block Temperature Range: 0 ℃ - 100 ℃
  • Temperature Accuracy: ≤ ± 0.2 ℃ (35 ℃ ~ 100 ℃)
  • Temperature Uniformity: ≤ ± 0.2 ℃
  • Ramping Rate: Adjustable

$ 4625 / Each of 1

Advanced Gradient Thermal Cycler LMAG-C101
  • Capacity: 96×0.2 ml
  • Tube: 0.2 ml tube,8 strips, Half skirt96 wells plate, No skirt 96 wells plate
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 5 °C/s
  • Uniformity: ≤ ± 0.2 °C

$ 4050 / Each of 1

Advanced Gradient Thermal Cycler LMAG-C102

  • Capacity: 96×0.2 ml
  • Tube: 0.2 ml tube,8 strips, Full 96 wells plate, Half skirt96 wells plate, No skirt 96 wells plate
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 6 °C/s
  • Uniformity: ≤ ± 0.2 °C

$ 4312.5 / Pack of 1

Advanced Thermal Cycler (Gradient) LMAT-B200

  • Block Capacity: 48 wells × 0.2 mL + 48 wells × 0.5 mL
  • Block Temperature Range: 0 ℃ to 100 ℃
  • Temperature Accuracy: ≤ ± 0.2℃ (35 ℃ ~ 100 ℃)
  • Temperature Uniformity: ≤ ± 0.2℃
  • Ramping Rate: Adjustable

$ 4912.5 / Each of 1

Advanced Gradient Thermal Cycler LMAG-C201

  • Capacity: 6×16×0.2 ml
  • Tube: 0.2ml tube, 8 strips, Half skirt96 wells plate, No skirt 96 wells plate
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 6 °C/s
  • Uniformity: ≤ ± 0.2 °C

$ 4400 / Each of 1

Advanced Thermal Cycler (Gradient) LMAT-B101
  • Block Capacity: 96 wells × 0.2 ml + 77 wells × 0.5 ml
  • Block Temperature Range: 0 ℃ to 99 ℃
  • Temperature Accuracy: ≤ ± 0.2 ℃
  • Temperature Uniformity: ≤ ± 0.2℃
  • Ramping Rate: 0.1℃ to 3 ℃

$ 4500 / Each of 1

Advanced Thermal Cycler (Basic) LMAT-A100
  • Capacity: 48 wells × 0.2 mL + 48 wells × 0.5 ml
  • Temperature Range: 0 ℃ to 99 ℃
  • Temperature Accuracy: ≤ ± 0.2℃
  • Temperature Uniformity: ≤ ± 0.2 ℃
  • Ramping Rate: 0.1 ℃ to 3 ℃

$ 4500 / Each of 1

Frequently Asked Questions

1 What is an Advanced Thermal Cycler (Basic) LMAT-A201?

An Advanced Thermal Cycler (Basic) LMAT-A201 is a high-performance PCR machine designed for a variety of molecular biology applications.

2 How does an Advanced Thermal Cycler (Basic) LMAT-A201 work?

An Advanced Thermal Cycler (Basic) LMAT-A201 operates on the principle of Polymerase Chain Reaction (PCR), a technique that amplifies specific DNA sequences through repeated cycles of denaturation, annealing, and extension.

3 Is Advanced Thermal Cycler (Basic) LMAT-A201 suitable for gene expression analysis?

Advanced Thermal Cycler (Basic) LMAT-A201 is used to amplify RNA sequences, which are then analyzed to study gene expression patterns.

4 Can Advanced Thermal Cycler (Basic) LMAT-A201 be used for pathogen detection?

Advanced Thermal Cycler (Basic) LMAT-A201 is used to detect pathogens by amplifying their DNA thereby enhancing the diagnosis of infectious diseases.

5 Can Advanced Thermal Cycler (Basic) LMAT-A201 be used in food safety testing?

Advanced Thermal Cycler (Basic) LMAT-A201 is used to amplify DNA from food samples to detect foodborne pathogens, thereby ensuring food safety.

6 Is Advanced Thermal Cycler (Basic) LMAT-A201 applicable in environmental monitoring?

Advanced Thermal Cycler (Basic) LMAT-A201 is used to detect microbial DNA in environmental samples, thereby facilitating the monitoring of pollution levels and the assessment of ecosystem health.

7 Can Advanced Thermal Cycler (Basic) LMAT-A201 be used in pharmaceutical research?

Advanced Thermal Cycler (Basic) LMAT-A201 is used in drug discovery and development by amplifying DNA sequences related to target genes.

8 Is Advanced Thermal Cycler (Basic)LMAT-A201 useful in agricultural research?

Advanced Thermal Cycler (Basic) LMAT-A201 is used to amplify DNA from plants to study genetic traits, resistance to diseases, and crop improvement.

9 How is Advanced Thermal Cycler (Basic) LMAT-A201 used in vaccine development?

Advanced Thermal Cycler (Basic) LMAT-A201plays a role in vaccine development by enabling the amplification and analysis of genetic material from pathogens.

10 What kind of maintenance does Advanced Thermal Cycler (Basic) LMAT-A201?

Regular maintenance includes cleaning of thermal block and vents and performing periodic calibration.

11 Can Advanced Thermal Cycler be used for DNA damage and repair studies?

It is used in DNA damage and repair studies to amplify damaged or repaired sequences and analyze repair pathway activity.

12 What is an Advanced Thermal Cycler?

An Advanced Thermal Cycler is a laboratory apparatus designed to amplify DNA segments by precisely controlling the temperature cycles required for polymerase chain reaction (PCR).

13 How does Advanced Thermal Cycler work?

It works by rapidly heating and cooling samples through programmed temperature steps, allowing DNA denaturation, annealing, and extension to occur during PCR.

14 How does Advanced Thermal Cycler support forensic DNA analysis?

It supports forensic DNA analysis by amplifying trace amounts of DNA from crime scene evidence for identification purposes.

15 How is Advanced Thermal Cycler applied in clinical diagnostics?

It is applied in clinical diagnostics to detect genetic disorders, infectious diseases, and cancer biomarkers through PCR-based tests.

16 Can Advanced Thermal Cycler be used in food safety testing?

It is used in food safety testing to detect bacterial contamination, allergens, and genetically modified organisms (GMOs).

17 Can Advanced Thermal Cycler be used in pharmacogenomics research in the lab?

It is used in pharmacogenomics to analyze genetic variations that affect drug metabolism and response, supporting personalized medicine.

18 How does Advanced Thermal Cycler support high-throughput screening in the lab?

It supports high-throughput screening by enabling simultaneous PCR amplification of multiple targets across 96- or 384-well plates.

19 Can Advanced Thermal Cycler be used for detecting antibiotic resistance genes in the lab?

It is used to amplify and detect antibiotic resistance genes in bacterial isolates through targeted PCR assays.

20 What role does Advanced Thermal Cycler play in metagenomic sample preparation?

It is used in metagenomics to amplify target microbial DNA from environmental or clinical samples prior to sequencing or analysis.