Get Quote

Contact us now to receive a detailed quotation.

Need quick help? Chat with us on WhatsApp:

WhatsApp QR Code

OR

Advanced Thermal Cycler (Gradient) LMAT-B100

Advanced Thermal Cycler (Gradient) LMAT-B100 features wide temperature range from 0°C to 99°C. It supports dual block configuration with 48 wells for 0.2 ml tubes and 48 wells for 0.5 ml tubes. Equipped with USB or LAN updates for integrating new features and software enhancements. Integrated touchscreen interface simplifies programming and operation. Our Advanced Thermal Cycler supports PCR, DNA analysis, gene expression, pathogen detection, and environmental testing.

Catalog Send Mail Whatsapp

Specifications

Block Capacity 48 wells × 0.2 ml + 48 wells × 0.5 ml
Block Temperature Range 0 ℃ to 99 ℃
Temperature Accuracy ≤ + 0.2 ℃
Temperature Uniformity ≤ ± 0.2℃
Ramping Rate 0.1℃ to 3 ℃
Heating Rate 3℃/s
Cooling Rate 2℃/s
Display Resolution 0.1℃
Gradient Temperature Range 30 ℃ to 99.9 ℃
Gradient Temperature Accuracy ≤ ± 0.3 ℃ (35 ℃ - 99.9 ℃)
Gradient Temperature Uniformity ≤ ± 0.3℃
Gradient Capacity 12 Columns (Vertical)
Temperature Differential Range 1℃ to 30 ℃
Hot-lid Temperature 105 ℃
Max No. of Program 125
Max No. of Cycles 99
Increment / Decrement Time 1 to 60 sec (Long PCR)
Increment / Decrement Temperature 0.1 ℃ to 10.0 ℃ (Touchdown PCR)
Display Blue Light LCD Display
Power Consumption 500 W
Power Supply AC 175 / 275 V; 50 / 60 Hz
Dimension 315 × 240 × 275 mm
Net Weight 9.8 Kg

Pricing

Product Price Unit Action
Advanced Thermal Cycler (Gradient) LMAT-B100 $ 4500 Each of 1

Features

Gradient-enabled for optimization

Fast thermal ramping 

Android OS with programs

Compact design with air vents

Auto self-closing hot lid

Corrosion-resistant aluminum build

Adjustable settings mid-run

Power-off recovery system

USB/Wi-Fi/mobile monitoring

Applications

Advanced Thermal Cycler (Gradient) LMAT-B100 is widely employed for PCR, DNA quantification, and gene expression studies. It supports pathogen detection and environmental testing across various fields.

Similar Products

Advanced Gradient Thermal Cycler LMAG-C202

  • Capacity: 96×0.2 ml
  • Tube: 0.2ml tube, 8 strips, Half skirt96 wells plate, No skirt 96 wells plate
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 8 °C/s
  • Uniformity: ≤ ± 0.2 °C

$ 5975 / Each of 1

Advanced Gradient Thermal Cycler LMAG-C402

  • Capacity: 64×0.2 ml (A Block) + 32×0.2ml (B Block)
  • Tube: 0.2 ml tube, 8 strips
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 5 °C/s
  • Uniformity: ≤ ± 0.2 °C

$ 6150 / Each of 1

Advanced Gradient Thermal Cycler LMAG-C301

  • Capacity: 384 well
  • Tube: 384 PCR microplate
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 5 °C/s
  • Uniformity: ≤ ± 0.2 °C

$ 4400 / Each of 1

Advanced Thermal Cycler (Gradient) LMAT-B201
  • Block Capacity: 96 wells × 0.2 mL + 77 wells × 0.5 mL
  • Block Temperature Range: 0 ℃ to 100 ℃
  • Temperature Accuracy: ≤ ± 0.2℃ (35 ℃ ~ 100 ℃)
  • Temperature Uniformity: ≤ ± 0.2℃
  • Ramping Rate: Adjustable

$ 4775 / Each of 1

Advanced Gradient Thermal Cycler LMAG-C102
  • Capacity: 96×0.2 ml
  • Tube: 0.2 ml tube,8 strips, Full 96 wells plate, Half skirt96 wells plate, No skirt 96 wells plate
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 6 °C/s
  • Uniformity: ≤ ± 0.2 °C

$ 4312.5 / Pack of 1

Advanced Gradient Thermal Cycler LMAG-C201

  • Capacity: 6×16×0.2 ml
  • Tube: 0.2ml tube, 8 strips, Half skirt96 wells plate, No skirt 96 wells plate
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 6 °C/s
  • Uniformity: ≤ ± 0.2 °C

$ 4400 / Each of 1

Advanced Thermal Cycler (Basic) LMAT-A101

  • Block Capacity: 96 wells × 0.2 ml + 77 wells × 0.5 ml
  • Block Temperature Range: 0 ℃ to 99 ℃
  • Temperature Accuracy: ≤ ± 0.2℃
  • Temperature Uniformity: ≤ ± 0.2 ℃
  • Ramping Rate: 0.1 ℃ to 3 ℃

$ 4500 / Each of 1

Advanced Thermal Cycler (Gradient) LMAT-B200

  • Block Capacity: 48 wells × 0.2 mL + 48 wells × 0.5 mL
  • Block Temperature Range: 0 ℃ to 100 ℃
  • Temperature Accuracy: ≤ ± 0.2℃ (35 ℃ ~ 100 ℃)
  • Temperature Uniformity: ≤ ± 0.2℃
  • Ramping Rate: Adjustable

$ 4912.5 / Each of 1

Advanced Thermal Cycler (Basic) LMAT-A200
  • Block Capacity: 48 wells × 0.2 mL + 48 wells × 0.5 mL
  • Block Temperature Range: 0 ℃ - 100 ℃
  • Temperature Accuracy: ≤ ± 0.2 ℃ (35 ℃ ~ 100 ℃)
  • Temperature Uniformity: ≤ ± 0.2 ℃
  • Ramping Rate: Adjustable

$ 4625 / Each of 1

Advanced Gradient Thermal Cycler LMAG-C501
  • Capacity: 64×0.2 ml (A Block) + 32×0.2 ml (B Block)
  • Tube: 0.2 ml tube, 8 strips
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 8 °C/s
  • Uniformity: ≤ ± 0.2 °C
Catalog

Advanced Gradient Thermal Cycler LMAG-C101

  • Capacity: 96×0.2 ml
  • Tube: 0.2 ml tube,8 strips, Half skirt96 wells plate, No skirt 96 wells plate
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 5 °C/s
  • Uniformity: ≤ ± 0.2 °C

$ 4050 / Each of 1

Advanced Gradient Thermal Cycler LMAG-C401

  • Capacity: 64×0.2 ml (A Block) + 32×0.2ml (B Block)
  • Tube: 0.2 ml tube, 8 strips
  • Temperature Range: 0 to 105 °C
  • Maximum. Ramp Rate: 5 °C/s
  • Uniformity: ≤ ± 0.2 °C

$ 4925 / Each of 1

Advanced Thermal Cycler (Basic) LMAT-A100

  • Capacity: 48 wells × 0.2 mL + 48 wells × 0.5 ml
  • Temperature Range: 0 ℃ to 99 ℃
  • Temperature Accuracy: ≤ ± 0.2℃
  • Temperature Uniformity: ≤ ± 0.2 ℃
  • Ramping Rate: 0.1 ℃ to 3 ℃

$ 4500 / Each of 1

Advanced Thermal Cycler (Gradient) LMAT-B101
  • Block Capacity: 96 wells × 0.2 ml + 77 wells × 0.5 ml
  • Block Temperature Range: 0 ℃ to 99 ℃
  • Temperature Accuracy: ≤ ± 0.2 ℃
  • Temperature Uniformity: ≤ ± 0.2℃
  • Ramping Rate: 0.1℃ to 3 ℃

$ 4500 / Each of 1

Advanced Thermal Cycler (Basic) LMAT-A201
  • Block Capacity: 98 wells × 0.2 mL + 77 wells × 0.5 mL, PCR strips, In-situ plate
  • Block Temperature Range: 0 ℃ to 100 ℃
  • Temperature Accuracy: ≤ ± 0.2 ℃ (35 ℃ ~ 100 ℃)
  • Temperature Uniformity: ≤ ± 0.2 ℃
  • Ramping Rate: Adjustable

$ 4500 / Pack of 1

Frequently Asked Questions

1 What is an Advanced Thermal Cycler (Gradient) LMAT-B100?

An Advanced Thermal Cycler (Gradient) LMAT-B100 is an apparatus designed for precise and efficient polymerase chain reaction (PCR) applications in molecular biology and genetics research.

2 How does an Advanced Thermal Cycler (Gradient) LMAT-B100 work?

An Advanced Thermal Cycler (Gradient) LMAT-B100 works on the principle of thermoelectric heating and cooling to precisely control temperature cycles required for DNA amplification through PCR.

3 Can Advanced Thermal Cycler (Gradient) LMAT-B100 be used in food safety testing?

Advanced Thermal Cycler (Gradient) LMAT-B100 detects foodborne pathogens like E. coli or Salmonella through PCR.

4 Can Advanced Thermal Cycler (Gradient) LMAT-B100 be used in pathogen detection for diagnostics?

Advanced Thermal Cycler (Gradient) LMAT-B100 is used to amplify pathogen-specific genes in clinical diagnostics.

5 Is Advanced Thermal Cycler (Gradient) LMAT-B100 suitable for detecting genetic mutations?

Advanced Thermal Cycler (Gradient) LMAT-B100 is suitable for mutation detection techniques like allele-specific PCR or SNP analysis.

6 Can Advanced Thermal Cycler (Gradient) LMAT-B100 perform RT-PCR for RNA analysis?

Advanced Thermal Cycler (Gradient) LMAT-B100 supports cDNA synthesis followed by PCR for analyzing gene expression.

7 Can Advanced Thermal Cycler (Gradient) LMAT-B100 be used for diagnosing sexually transmitted infections (STIs)?

Advanced Thermal Cycler (Gradient) LMAT-B100 is used to detect DNA or RNA from pathogens like HPV, chlamydia, and gonorrhoea through molecular assays.

8 Can Advanced Thermal Cycler (Gradient) LMAT-B100 be used in drug-resistance testing for infectious diseases?

Advanced Thermal Cycler (Gradient) LMAT-B100 identifies resistance genes in pathogens, guiding effective antimicrobial therapy.

9 Is Advanced Thermal Cycler (Gradient) LMAT-B100 useful in blood screening for transfusion safety?

Advanced Thermal Cycler (Gradient) LMAT-B100 detects viral and bacterial contaminants such as HIV, HBV, and HCV in donor blood samples.

10 What kind of maintenance does Advanced Thermal Cycler (Gradient) LMAT-B100 require?

Regular maintenance includes cleaning of the block, lid, and vents, and performing temperature calibration.

11 Can Advanced Thermal Cycler be used for DNA damage and repair studies?

It is used in DNA damage and repair studies to amplify damaged or repaired sequences and analyze repair pathway activity.

12 What is an Advanced Thermal Cycler?

An Advanced Thermal Cycler is a laboratory apparatus designed to amplify DNA segments by precisely controlling the temperature cycles required for polymerase chain reaction (PCR).

13 How does Advanced Thermal Cycler work?

It works by rapidly heating and cooling samples through programmed temperature steps, allowing DNA denaturation, annealing, and extension to occur during PCR.

14 How does Advanced Thermal Cycler support forensic DNA analysis?

It supports forensic DNA analysis by amplifying trace amounts of DNA from crime scene evidence for identification purposes.

15 How is Advanced Thermal Cycler applied in clinical diagnostics?

It is applied in clinical diagnostics to detect genetic disorders, infectious diseases, and cancer biomarkers through PCR-based tests.

16 Can Advanced Thermal Cycler be used in food safety testing?

It is used in food safety testing to detect bacterial contamination, allergens, and genetically modified organisms (GMOs).

17 Can Advanced Thermal Cycler be used in pharmacogenomics research in the lab?

It is used in pharmacogenomics to analyze genetic variations that affect drug metabolism and response, supporting personalized medicine.

18 How does Advanced Thermal Cycler support high-throughput screening in the lab?

It supports high-throughput screening by enabling simultaneous PCR amplification of multiple targets across 96- or 384-well plates.

19 Can Advanced Thermal Cycler be used for detecting antibiotic resistance genes in the lab?

It is used to amplify and detect antibiotic resistance genes in bacterial isolates through targeted PCR assays.

20 What role does Advanced Thermal Cycler play in metagenomic sample preparation?

It is used in metagenomics to amplify target microbial DNA from environmental or clinical samples prior to sequencing or analysis.