Q-Gene Thermal Cycler LMTC-A301 is on-demand equipment with Peltier heating units which can process maximum 100 cycles. It can accommodate 16×0.2 ml (4×4 layout) sample with 0.2 ml single tube. We have advanced configuration of windows operations system and 5-inches TFT color touch-screen with graphical display. This device can be applied across a temperature range of 4 to100 °C with maximum ramping rate is 5 °C/s. It has unique approach to the user to secure his data using password and user login method. Offered with pre-installed 11 standard protocol broad and interfacing compatibility via USB, printer support.
HSCode:84192090
Get QuoteCapacity | 16×0.2 ml (4×4 layout) |
Tube | 0.2 ml single tube |
Temperature Range | 4 to 100 °C |
Maximum. Heating Rate | 5 °C/s |
Maximum. Cooling Rate | 4 °C/s |
Uniformity | ≤ ± 0.2 °C |
Accuracy | ≤ ± 0.2 °C |
Display Resolution | 0.1 °C |
Temperature Control | Block/ Tube |
Ramping Rate Adjustable | 0.1 to 5 °C |
Gradient Temperature. Range | NA |
Gradient Spread | NA |
Hot Lid Temperature | 30 to 110 °C |
Number Of Programs | 10000 +(USB FLASH) |
Maximum. No. Of Step | 30 |
Maximum. No. Of Cycle | 100 |
Increment/Decrement Time | 1 Sec to 600 Sec |
Increment/Decrement Temperature | 0.1 to 10.0 °C |
Pause Function | Yes |
Auto Data Protection | Yes |
Holding | 4 °C |
Touchdown Function | Yes |
Long PCR Function | Yes |
Computer Software | Yes |
Mobile Phone App | Yes |
LCD | 5 inch,800×480 pels, 65K color |
Interface | USB2.0 , WIFI |
Dimensions(L×W×H) | 267×190×115 mm |
Weight | 2.5 kg |
Power Consumption | 120 W |
Power Supply | 85 to 264 V AC,47 to 63 Hz |
Uniform heating with 3 different temperature of the samples is achieved with Peltier heating units with maximum 100 cycles
It is well built with anodizing technology with aluminium block treatment which makes the durable and corrosion resistant
Maximum heating rate is 5 °C/s with temperature range of 4 to 100 °C
It has the capability to accommodate 16×0.2 ml (4×4 layout) and 32×0.2 ml (4×8 layout) with moveable hot lid which can fit different sizes of tubes
It has the internal flash memory to store the 10000 files data for analysis
The connectivity between computer is via USB port and mini printer and can store the GLP data after every step to get reliable results
All the operations are controlled by a computer software system which instrument PCR protocols and also has in built 11 standard protocols
It has power of operation recovery option which helps in continuing the same command after a recovering from power cut
The user can access to his individual experimental data by setting a password and data management system
To satisfy the customers need it is installed with special feature like the user can add sample while the process is going on to encounter different variations
The user will be sent notifications via email about the process to alert when operation ends
Used in Gene expression analysis, Pathogen detection, DNA methylation analysis, Genotyping and gene scanning, miRNA research etc.
Get Quote for