Ask An Expert

We will Follow up with you within 24 hours.

Touch Screen Thermal Cycler (Gradient) LMTC-B106

Catalog

Specifications

Block Capacity
Block Temperature Range 0 °C - 100 °C
Temperature Accuracy ≤ ± 0.2 °C (35 °C - 100 °C)
Temperature Uniformity ± 0.2 °C (95 °C)
Ramping Rate Adjustable
Heating Rate 3.5 °C/s
Cooling Rate 3 °C/s
Display Resolution 0.1 °C
Gradient Temperature Range 30 °C - 99.9 °C
Gradient Temperature Accuracy ≤ ± 0.3 °C (35 °C - 100 °C)
Gradient Temperature Uniformity ≤ ± 0.3 °C (95 °C)
Gradient Capacity 12 Column (Vertical)
Temperature Differential Range 1 °C - 30 °C
Hot-lid Temperature Range
Max No. of Steps 30
Max No. of Program 15000
Max No. of Cycles 100
Increment / Decrement Time Available (Long PCR)
Increment / Decrement Temperature Available (Touchdown PCR)
Display 7” Color Touch Screen
Data Output Port USB 2.0 / RS232 / LAN
Power Consumption 600 W
Power Supply AC 175 V / 275 V; 50 / 60 Hz
Dimension 362 x 256 x 255 mm
Net Weight 7.3 Kg
Gross Weight

Pricing

Product Price Unit Action
Touch Screen Thermal Cycler (Gradient) LMTC-B106 $4,480.00 Pack of 1

Features

Touch Screen for smooth operation Gradient function for temperature stability Real time observation on 7” color display Peltier based heating and cooling control Interchangeable modules Automatic calculation of annealing temperature Stepless adjustable Hot-lid to avoid evaporation Auto shut off when temperature is ˂ 30 °C or after cycle Auto pause / start during technical errors Block / Tube temperature control mode

Optional Modules

Model No. Module Image
M-01 48 Module: 48 wells x 0.2 mL + 48 wells x 0.5 mL
M-02 96 Module: 96 wells x 0.2 mL
M-03 96+77 Module: 96 wells x 0.2 mL + 77 wells x 0.5 mL
M-04 384 Module: 384 wells plate
M-05 Multi-purpose Module: 96+77 Module and In situ Adaptor

Similar Products

Touch Screen Thermal Cycler (Basic) LMTC-A100

  • Block Capacity: 16 wells x 0.2 mL
  • Block Temperature Range: 0.1 °C - 99.9 °C
  • Temperature Accuracy: ± 0.25 °C
  • Temperature Uniformity: ± 0.25 °C
  • Ramping Rate: Adjustable

Touch Screen Thermal Cycler (Basic) LMTC-A102

  • Block Capacity: 32 wells x 0.2 mL
  • Block Temperature Range: 4 °C - 100 °C
  • Temperature Accuracy: ± 0.25 °C
  • Temperature Uniformity: ± 0.25 °C
  • Ramping Rate: Adjustable

Touch Screen Thermal Cycler (Basic) LMTC-A200

  • Capacity: 96
  • Reaction Volume: 10 to 200ul
  • Tube Type: 96×0.2ml PCR plate, 8×0.2ml PCR tube
  • Block Temperature Range: 4°C to 105°C
  • Heat Lid Temperature Rangs: 30°C to 110°C
Touch Screen Thermal Cycler (Basic) LMTC-A103
  • Block Capacity: 32 wells x 0.2 mL
  • Block Temperature Range: 0.1 °C - 99.9 °C
  • Temperature Accuracy: ± 0.25 °C
  • Temperature Uniformity: ± 0.25 °C
  • Ramping Rate: Adjustable
Touch Screen Thermal Cycler (Basic) LMTC-A105
  • Block Capacity: 48 x 0.2 mL , 6 x 8 PCR Strip
  • Block Temperature Range: 4 °C - 99.9 °C
  • Temperature Accuracy: ≤ ± 0.1 °C (55 °C) ; ≤ ± 0.2 °C (≥ 90 °C)
  • Temperature Uniformity: ± 0.2 °C
  • Ramping Rate: 0.1 °C - 4 °C

Touch Screen Thermal Cycler (Gradient) LMTC-B200

  • Block Capacity: 6 x 16 wells x 0.2 mL , 96 wells x 0.2 mL , 12 x 8 PCR strips
  • Block Temperature Range: 4 °C - 100 °C
  • Temperature Accuracy: 4 °C - 100 °C
  • Temperature Uniformity: ≤ ± 0.15 °C (≥ 90 °C)
  • Ramping Rate: 0.1 °C - 4 °C

Touch Screen Thermal Cycler (Gradient) LMTC-B102

  • Block Capacity: 96 x 0.2 mL , 12 x 8 PCR Strip
  • Block Temperature Range: 4 °C - 99.9 °C
  • Temperature Accuracy: ≤ ± 0.1 °C (50 °C) ; ≤ ± 0.15 °C (≥ 95 °C) ; ≤ ± 0.15 °C (≥ 72 °C)
  • Temperature Uniformity: ± 0.2 °C
  • Ramping Rate: 0.1 °C - 4 °C

Touch Screen Thermal Cycler (Basic) LMTC-A101

  • Block Capacity: 16 wells x 0.2 mL
  • Block Temperature Range: 4 °C - 100 °C
  • Temperature Accuracy: ± 0.25 °C
  • Temperature Uniformity: ± 0.25 °C
  • Ramping Rate: Adjustable
Touch Screen Thermal Cycler (Gradient) LMTC-B101
  • Block Capacity: 96 x 0.2 mL , 12 x 8 PCR Strip
  • Block Temperature Range: 4 °C - 99.9 °C
  • Temperature Accuracy: ≤ ± 0.1 °C (50 °C) ; ≤ ± 0.2 °C (≥ 90 °C)
  • Temperature Uniformity: ± 0.2 °C
  • Ramping Rate: 0.1 °C - 4 °C
Touch Screen Thermal Cycler (Gradient) LMTC-B105
  • Block Capacity:
  • Block Temperature Range: 0 °C - 100 °C
  • Temperature Accuracy: ≤ ± 0.2 °C (35 °C - 100 °C)
  • Temperature Uniformity: ± 0.2 °C (95 °C)
  • Ramping Rate: Adjustable

Touch Screen Thermal Cycler (Basic) LMTC-A107

  • Block Capacity:
  • Block Temperature Range: 0 °C - 100 °C
  • Temperature Accuracy: ≤ ± 0.2 °C (35 °C - 100 °C)
  • Temperature Uniformity: ± 0.2 °C (95 °C)
  • Ramping Rate: Adjustable

Touch Screen Thermal Cycler (Basic) LMTC-A104

  • Block Capacity: 30 x 0.5 mL , 40 x 0.2 mL , 4 x 12 PCR Strip
  • Block Temperature Range: 4 °C - 99.9 °C
  • Temperature Accuracy: ≤ ± 0.1 °C (55 °C) ; ≤ ± 0.2 °C (≥ 90 °C)
  • Temperature Uniformity: ± 0.2 °C
  • Ramping Rate: 0.1 °C - 4 °C

Touch Screen Thermal Cycler (Gradient) LMTC-B103

  • Block Capacity: 96 x 0.2 mL , 12 x 8 PCR Strip
  • Block Temperature Range: 4 °C - 99.9 °C
  • Temperature Accuracy: ≤ ± 0.1 °C (50 °C) ; ≤ ± 0.2 °C (≥ 90 °C)
  • Temperature Uniformity: ± 0.3 °C
  • Ramping Rate: 0.1 °C - 4 °C
Touch Screen Thermal Cycler (Basic) LMTC-A106
  • Block Capacity: 96 wells x 0.2 mL
  • Block Temperature Range: 4 °C - 99.9 °C
  • Temperature Accuracy: ≤ ± 0.1 °C (55 °C) ; ≤ ± 0.2 °C (≥ 90 °C)
  • Temperature Uniformity: ± 0.2 °C
  • Ramping Rate: 0.1 °C - 4 °C
Touch Screen Thermal Cycler (Basic) LMTC-A108
  • Block Capacity:
  • Block Temperature Range: 0 °C - 100 °C
  • Temperature Accuracy: ≤ ± 0.2 °C (35 °C - 100 °C)
  • Temperature Uniformity: ± 0.2 °C (95 °C)
  • Ramping Rate: Adjustable