Block Capacity 48 x 0.2 mL , 6 x 8 PCR Strip
Block Temperature Range 4 °C - 99.9 °C
Temperature Accuracy ≤ ± 0.1 °C (55 °C) ; ≤ ± 0.2 °C (≥ 90 °C)
Temperature Uniformity ± 0.2 °C
Ramping Rate 0.1 °C - 4 °C
Heating Rate 4 °C/s
Cooling Rate 4 °C/s
Hot-lid Temperature Range 30 °C - 110 °C
Max No. of Program More than 250
Max No. of Cycles 99
Increment / Decrement Time 0 - 9 min 59 sec (Long PCR)
Increment / Decrement Temperature 0.1 °C - 9.9 °C (Touchdown PCR)
Display 6.5” LCD Color Touch Screen
Data Output Port LAN
Power Consumption 600 W
Power Supply AC 110 V / 220 V ± 10 %; 50 / 60 Hz
Gross Weight 12.5 Kg

Pricing

Product Price Unit Action
Touch Screen Thermal Cycler (Basic) LMTC-A105 $ 6562.5 Pack of 1

Features

Touch Screen for smooth operation Real time observation on 6.5” LCD color display Peltier based heating and cooling control SOAK function helps maintain annealing temperature Stepless adjustable Hot-lid to avoid evaporation Auto shut off when temperature is ˂ 30 °C or after cycle Auto pause / start during technical errors Block / Tube temperature control mode

Similar Products

Touch Screen Thermal Cycler (Gradient) LMTC-B107

  • Block Temperature Range: 0 °C - 100 °C
  • Temperature Accuracy: ≤ ± 0.2 °C (35 °C - 100 °C)
  • Temperature Uniformity: ± 0.2 °C (95 °C)
  • Ramping Rate: Adjustable
  • Heating Rate: 3.5 °C/s

$ 6150 / Pack of 1

Touch Screen Thermal Cycler (Basic) LMTC-A108

  • Block Temperature Range: 0 °C - 100 °C
  • Temperature Accuracy: ≤ ± 0.2 °C (35 °C - 100 °C)
  • Temperature Uniformity: ± 0.2 °C (95 °C)
  • Ramping Rate: Adjustable
  • Heating Rate: 3.5 °C/s

$ 5450 / Pack of 1

Touch Screen Thermal Cycler (Gradient) LMTC-B108

  • Block Temperature Range: 0 °C - 100 °C
  • Temperature Accuracy: ≤ ± 0.2 °C (35 °C - 100 °C)
  • Temperature Uniformity: ± 0.2 °C (95 °C)
  • Ramping Rate: Adjustable
  • Heating Rate: 3.5 °C/s

$ 5825 / Pack of 1

Touch Screen Thermal Cycler (Gradient) LMTC-B102
  • Block Capacity: 96 x 0.2 mL , 12 x 8 PCR Strip
  • Block Temperature Range: 4 °C - 99.9 °C
  • Temperature Accuracy: ≤ ± 0.1 °C (50 °C) ; ≤ ± 0.15 °C (≥ 95 °C) ; ≤ ± 0.15 °C (≥ 72 °C)
  • Temperature Uniformity: ± 0.2 °C
  • Ramping Rate: 0.1 °C - 4 °C

$ 8600 / Pack of 1

Touch Screen Thermal Cycler (Basic) LMTC-A200
  • Capacity: 96
  • Reaction Volume: 10 to 200ul
  • Tube Type: 96×0.2ml PCR plate, 8×0.2ml PCR tube
  • Block Temperature Range: 4°C to 105°C
  • Heat Lid Temperature Rangs: 30°C to 110°C

$ 5275 / Pack of 1

Touch Screen Thermal Cycler (Gradient) LMTC-B105

  • Block Temperature Range: 0 °C - 100 °C
  • Temperature Accuracy: ≤ ± 0.2 °C (35 °C - 100 °C)
  • Temperature Uniformity: ± 0.2 °C (95 °C)
  • Ramping Rate: Adjustable
  • Heating Rate: 3.5 °C/s

$ 5050 / Pack of 1

Touch Screen Thermal Cycler (Gradient) LMTC-B101

  • Block Capacity: 96 x 0.2 mL , 12 x 8 PCR Strip
  • Block Temperature Range: 4 °C - 99.9 °C
  • Temperature Accuracy: ≤ ± 0.1 °C (50 °C) ; ≤ ± 0.2 °C (≥ 90 °C)
  • Temperature Uniformity: ± 0.2 °C
  • Ramping Rate: 0.1 °C - 4 °C

$ 4787.5 / Pack of 1

Touch Screen Thermal Cycler (Basic) LMTC-A102

  • Block Capacity: 32 wells x 0.2 mL
  • Block Temperature Range: 4 °C - 100 °C
  • Temperature Accuracy: ± 0.25 °C
  • Temperature Uniformity: ± 0.25 °C
  • Ramping Rate: Adjustable

$ 3350 / Pack of 1

Touch Screen Thermal Cycler (Gradient) LMTC-B106
  • Block Temperature Range: 0 °C - 100 °C
  • Temperature Accuracy: ≤ ± 0.2 °C (35 °C - 100 °C)
  • Temperature Uniformity: ± 0.2 °C (95 °C)
  • Ramping Rate: Adjustable
  • Heating Rate: 3.5 °C/s

$ 5600 / Pack of 1

Touch Screen Thermal Cycler (Basic) LMTC-A100
  • Block Capacity: 16 wells x 0.2 mL
  • Block Temperature Range: 0.1 °C - 99.9 °C
  • Temperature Accuracy: ± 0.25 °C
  • Temperature Uniformity: ± 0.25 °C
  • Ramping Rate: Adjustable

$ 6412.5 / Pack of 1

Touch Screen Thermal Cycler (Gradient) LMTC-B200

  • Block Capacity: 6 x 16 wells x 0.2 mL , 96 wells x 0.2 mL , 12 x 8 PCR strips
  • Block Temperature Range: 4 °C - 100 °C
  • Temperature Accuracy: 4 °C - 100 °C
  • Temperature Uniformity: ≤ ± 0.15 °C (≥ 90 °C)
  • Ramping Rate: 0.1 °C - 4 °C

$ 6675 / Pack of 1

Touch Screen Thermal Cycler (Gradient) LMTC-B100

  • Block Capacity: 96 x 0.2 mL , 12 x 8 PCR Strip
  • Block Temperature Range: 4 °C - 99.9 °C
  • Temperature Accuracy: ≤ ± 0.1 °C (55 °C) ; ≤ ± 0.2 °C (≥ 90 °C)
  • Temperature Uniformity: ± 0.2 °C
  • Ramping Rate: 0.1 °C - 4 °C

$ 6562.5 / Pack of 1

Touch Screen Thermal Cycler (Basic) LMTC-A103

  • Block Capacity: 32 wells x 0.2 mL
  • Block Temperature Range: 0.1 °C - 99.9 °C
  • Temperature Accuracy: ± 0.25 °C
  • Temperature Uniformity: ± 0.25 °C
  • Ramping Rate: Adjustable

$ 3175 / Pack of 1

Touch Screen Thermal Cycler (Basic) LMTC-A106
  • Block Capacity: 96 wells x 0.2 mL
  • Block Temperature Range: 4 °C - 99.9 °C
  • Temperature Accuracy: ≤ ± 0.1 °C (55 °C) ; ≤ ± 0.2 °C (≥ 90 °C)
  • Temperature Uniformity: ± 0.2 °C
  • Ramping Rate: 0.1 °C - 4 °C

$ 6962.5 / Pack of 1

Touch Screen Thermal Cycler (Basic) LMTC-A104
  • Block Capacity: 30 x 0.5 mL , 40 x 0.2 mL , 4 x 12 PCR Strip
  • Block Temperature Range: 4 °C - 99.9 °C
  • Temperature Accuracy: ≤ ± 0.1 °C (55 °C) ; ≤ ± 0.2 °C (≥ 90 °C)
  • Temperature Uniformity: ± 0.2 °C
  • Ramping Rate: 0.1 °C - 4 °C

$ 7237.5 / Pack of 1

Frequently Asked Questions

1 What is a Touch Screen Thermal Cycler (Basic) LMTC-A105?

A Touch Screen Thermal Cycler (Basic) LMTC-A105 is a compact and efficient PCR (Polymerase Chain Reaction) machine designed for routine molecular biology applications.

2 How does a Touch Screen Thermal Cycler (Basic) LMTC-A105 work?

A Touch Screen Thermal Cycler (Basic) LMTC-A105 works on the principle of thermal cycling, using precise temperature changes to amplify DNA through the polymerase chain reaction (PCR).

3 Can Touch Screen Thermal Cycler (Basic) LMTC-A105 device support RNA virus detection through RT-PCR?

Touch Screen Thermal Cycler (Basic) LMTC-A105 is used for reverse transcription, it enables RNA virus detection such as for influenza or SARS-CoV-2.

4 Is Touch Screen Thermal Cycler (Basic) LMTC-A105 applicable in plant genomics?

Touch Screen Thermal Cycler (Basic) LMTC-A105 is used to amplify plant DNA for genetic mapping, trait analysis, or transgene confirmation.

5 Can Touch Screen Thermal Cycler (Basic) LMTC-A105 be used for STR analysis?

Touch Screen Thermal Cycler (Basic) LMTC-A105 supports PCR protocols used in short tandem repeat (STR) profiling for genetic studies.

6 Can Touch Screen Thermal Cycler (Basic) LMTC-A105 be used for detecting antibiotic resistance genes?

Touch Screen Thermal Cycler (Basic) LMTC-A105 enables amplification of specific antibiotic resistance gene markers in microbial samples.

7 Is Touch Screen Thermal Cycler (Basic) LMTC-A105 applicable for studying ancient or degraded DNA samples?

Touch Screen Thermal Cycler (Basic) LMTC-A105 high sensitivity and accurate thermal control make it suitable for low-yield or fragmented DNA.

8 Is Touch Screen Thermal Cycler (Basic) LMTC-A105 suitable for synthetic biology workflows?

Touch Screen Thermal Cycler (Basic) LMTC-A105 facilitates DNA assembly and amplification steps used in synthetic construct development.

9 Can Touch Screen Thermal Cycler (Basic) LMTC-A105 be used for validating CRISPR edits?

Touch Screen Thermal Cycler (Basic) LMTC-A105 amplifies target regions to verify insertions, deletions, or mutations introduced by CRISPR.

10 What kind of maintenance does Touch Screen Thermal Cycler (Basic) LMTC-A105 require?

Routine maintenance involves regularly cleaning the thermal block and exterior, performing software updates, and inspecting vents for dust or debris.

11 What is a Touch Screen Thermal Cycler?

A Touch Screen Thermal Cycler is an apparatus designed with a user-friendly touch screen interface for easy programming and temperature control.

12 How does Touch Screen Thermal Cycler work?

It works by cycling through precise temperature changes needed for DNA denaturation, annealing, and extension, controlled via a user-friendly touch screen display.

13 How is Touch Screen Thermal Cycler used in genetic testing?

It is used in genetic testing to amplify specific DNA sequences, enabling the detection of genetic mutations and hereditary conditions.

14 How does Touch Screen Thermal Cycler support forensic DNA analysis?

It supports forensic DNA analysis by providing accurate and reproducible DNA amplification from trace biological evidence.

15 How does Touch Screen Thermal Cycler aid in agricultural biotechnology?

It aids in agricultural biotechnology by enabling the detection of genetically modified organisms (GMOs) and plant pathogen diagnostics.

16 How is Touch Screen Thermal Cycler used in microbial identification?

It helps identify microbes by amplifying species-specific genes, which can then be sequenced or analyzed for identification.

17 Can Touch Screen Thermal Cycler be used in food safety testing?

It is used in food safety testing to detect foodborne pathogens like Salmonella, Listeria, and E. coli through PCR-based methods.

18 How does Touch Screen Thermal Cycler benefit clinical diagnostics?

It benefits clinical diagnostics by providing fast and reliable amplification of nucleic acids for identifying infectious diseases and genetic disorders.

19 How is Touch Screen Thermal Cycler used in vaccine development?

It is used in vaccine development to clone and amplify genes encoding antigens for further study and vaccine formulation.

20 Is Touch Screen Thermal Cycler used in water quality testing?

It is used in water quality testing to detect microbial contaminants using PCR-based assays.