Air Cooled Chiller LMACR-A106 is equipped with a 500 L water tank for efficient large-scale applications. It provides a versatile flow rate range from 250 to 500 L/min, ensuring adaptability. It features an advanced condenser fan with 21,000 m³/h, optimizing heat dissipation. It is constructed with poly-foam type rubberized tube insulation, offering enhanced durability. Our Air-Cooled Chiller has compact dimensions of 1830 × 860 × 1900 mm, ensuring easy space integration.

Catalog Send Mail Whatsapp

Specifications

Water Tank Capacity 500 L
Flow Rate 250 to 500 L / Min
Refrigerant R22
Condenser Fan 21000 m³/h (CHM)
Insulation Material Poly-foam type rubberized tube
Water Pump 3kW
Compressor Motor 18.75 kW
Cooling Capacity 69700 W
Current 45 Amps
Voltage 380V to 400 V, 3 Phase (50 to 60 Hz)
Fan Diameter 600 mm × 3 sets
Dimension (L × W × H) 1830 × 860 × 1900 mm
Net Weight 780 kg

Features

Superior Cooling Capacity

Powerful Compressor Motor

High Proficiency Pump

Low Energy Consumption

Wide Voltage Range

Robust Construction

Applications

Air Cooled Chiller LMACR-A106 is vital for ensuring precise temperature control in chemical processes and storage.

Similar Products

Air Cooled Chiller LMACR-A104

  • Water Tank Capacity: 380 L
  • Flow Rate: 160 to 320 L / Min
  • Refrigerant: R22
  • Condenser Fan: 12600 m³/h (CHM)
  • Insulation Material: Poly-foam type rubberized tube

Air Cooled Chiller LMACR-A109

  • Water Tank Capacity: 800 L
  • Flow Rate: 400 to 800 L / Min
  • Refrigerant: R22
  • Condenser Fan: 39000 m³/h (CHM)
  • Insulation Material: Poly-foam type rubberized tube

Air Cooled Chiller LMACR-A108

  • Water Tank Capacity: 630 L
  • Flow Rate: 400 to 800 L / Min
  • Refrigerant: R22
  • Condenser Fan: 31200 m³/h (CHM)
  • Insulation Material: Poly-foam type rubberized tube
Air Cooled Chiller LMACR-A100
  • Water Tank Capacity: 65 L
  • Cooling Capacity: 8250 W, 29000 BTU / hr
  • Flow Rate: 50 - 100L / Min
  • Water Pump: 1 / 2 HP, 0.37 kW
  • Refrigerant Type: R22
Air Cooled Chiller LMACR-A105
  • Water Tank Capacity: 500 L
  • Flow Rate: 160 to 320 L / Min
  • Refrigerant: R22
  • Condenser Fan: 18900 m³/h (CHM)
  • Insulation Material: Poly-foam type rubberized tube

Air Cooled Chiller LMACR-A103

  • Water Tank Capacity: 220 L
  • Cooling Capacity: 28400 W, 97000 BTU / hr
  • Flow Rate: 100 - 200 L / Min
  • Water Pump: 1 HP, 0.75 kW
  • Refrigerant Type: R22

Air Cooled Chiller LMACR-A107

  • Water Tank Capacity: 520 L
  • Flow Rate: 250 to 500 L / Min
  • Refrigerant: R22
  • Condenser Fan: 23400 m³/h (CHM)
  • Insulation Material: Poly-foam type rubberized tube

Air Cooled Chiller LMACR-A102

  • Water Tank Capacity: 140 L
  • Cooling Capacity: 20540 W, 77300 BTU / hr
  • Flow Rate: 100 - 200 L / Min
  • Water Pump: 1 HP, 0.75 kW
  • Refrigerant Type: R22
Air Cooled Chiller LMACR-A101
  • Water Tank Capacity: 65 L
  • Cooling Capacity: 11324 W, 38650 BTU / hr
  • Flow Rate: 50 - 100 L / Min
  • Water Pump: 1 / 2HP, 0.37 kW
  • Refrigerant Type: R22

Frequently Asked Questions

1 What is an Air Cooled Chiller?

An Air Cooled Chiller is an apparatus designed to use ambient air to remove heat from a process or space by circulating refrigerant through a vapor-compression cycle.

2 How does an Air Cooled Chiller work?

It operates by compressing refrigerant, extracting heat from a fluid, and dissipating it via air-cooled coils.

3 What kind of maintenance does Air Cooled Chiller require?

Regular maintenance includes cleaning condenser coils, checking refrigerant pressure, inspecting electrical components, and verifying temperature set points.

4 Can Air Cooled Chiller be used in industrial manufacturing?

It is widely used in industrial manufacturing to cool machinery, hydraulic systems and process fluids.

5 Is Air Cooled Chiller suitable for plastic molding process?

It is commonly used in plastic molding to maintain precise mold temperatures and improve cycle times and product consistency.

6 How does Air Cooled Chiller benefit hospitals and healthcare facilities?

It supports critical HVAC systems in healthcare facilities, ensuring reliable temperature control in patient rooms, operating theaters, and labs.

7 Is Air Cooled Chiller suitable for pharmaceutical production?

It is used in pharmaceutical facilities for temperature control in manufacturing, packaging, and cleanroom environments.

8 Is Air Cooled Chiller effective for greenhouse or agricultural cooling?

It is used to regulate climate conditions in greenhouses or agriculture facilities, protecting plants from heat stress and maintaining growth cycles.

9 Can Air Cooled Chiller be used in textile manufacturing?

It is used to cool dyeing machines, maintain ambient factory temperatures, and prevent yarn or fabric distortion.

10 Can Air Cooled Chiller be used in laboratories and research centers?

It is vital for temperature control in scientific equipment such as electron microscopes, laser systems, and climate chambers.