Microplate Reader LMMR-M104

Microplate Reader LMMR-M104 offers 96-well plate scan in 5 seconds. Its advanced fibre optic system enhances signal detection. It features built-in incubation for controlled temperature conditions. Its adjustable shaking optimizes sample mixing for consistent readings. Our Microplate Reader is ideal for Clinical diagnostics and pharmaceutical research. 

Catalog Send Mail Whatsapp

Specifications

Wavelength Range 340 to 750nm
Filter Bandwidth 8 to 10nm
Standard Filters 405nm, 450nm, 492nm, 630nm
Filter 8-bit filter wheel
Optical System 13 channels
Absorbance Range 0 to 4.000Abs
Linearity R² greater than or equal to 0.995
Incubation Temperature Range Room Temperature +4°C to 65°C
Resolution 0.001Abs
Wavelength Accuracy Less than or equal to ±2nm
Measuring Speed 5s
Single wavelength Less than 7s/96 wells
Dual wavelength Less than 15s/96 wells
Program Storage 5000
Power Consumption 200W
Power Supply 100 to 240V, 50/60Hz
Dimensions 300 × 430 × 232mm
Weight 10kg

Pricing

Product Price Unit Action
Microplate Reader LMMR-M104 $ 3997.5 Each of 1

Features

Single And Dual Wavelength Detection

High-Resolution Touch Screen

Halogen Lamp

Photodiode Detector 

USB Interface

Optional Accessories

Model No

Accessory

Unit

Quantity

LMMR-M104-F1 

405nm Filter

Each

1

LMMR-M104-F2

450nm Filter

Each

1

LMMR-M104-F3

492nm Filter

Each

1

LMMR-M104-F4

630nm Filter

Each

1

LMMR-M104-F5

415nm Filter

Each

1

LMMR-M104-F6

470nm Filter

Each

1

LMMR-M104-F7

510nm Filter

Each

1

LMMR-M104-F8

520nm Filter

Each

1

LMMR-M104-F9

532nm Filter

Each

1

LMMR-M104-F10

540nm Filter

Each

1

LMMR-M104-F11

546nm Filter

Each

1

LMMR-M104-F12

570nm Filter

Each

1

LMMR-M104-F13

578nm Filter

Each

1

LMMR-M104-F14

595nm Filter

Each

1

LMMR-M104-F15

600nm Filter

Each

1

LMMR-M104-F16

620nm Filter

Each

1

LMMR-M104-F17

650nm Filter

Each

1

LMMR-M104-F18

660nm Filter

Each

1

LMMR-M104-F19

690nm Filter

Each

1

LMMR-M104-F20

700nm Filter

Each

1

LMMR-M104-F21

750nm Filter

Each

1

Applications

Microplate Reader LMMR-M104 is ideal for clinical diagnostics, pharmaceutical research, biotechnology & microbiology for ELISA, drug discovery, bioassays and enzyme activity studies.

Selection Guide

Microplate Reader LMMR-M104 is a reliable and high-performance instrument designed for a variety of research and diagnostic applications, including ELISA assays, protein quantification, enzyme kinetics, and cell-based studies. Widely used in research studies for cytokine profiling, pathogen detection, and drug screening, this model supports both 96-well and 384-well plates with a broad wavelength range of 400–800 nm, ensuring accurate and reproducible absorbance measurements. It features user-friendly software for data analysis, kinetic evaluation, and multi-wavelength readings, making it suitable for both routine and complex assays. The device typically holds CE certification and may comply with ISO standards, ensuring quality and safety for use in regulated laboratories. Its durable design, ease of maintenance, and compatibility with high-throughput experiments make it a strong choice for professionals seeking accuracy, efficiency, and regulatory compliance in their microplate-based workflows.

Similar Products

Microplate Reader LMRW-A100

  • Plate type: 96 well plate
  • Standard Wavelength: 405, 450, 492, 630 nm
  • Wavelength accuracy: ± 1 nm
  • Resolution: 0.001 Abs
  • Reading speed (Single wavelength): 5 secs for 96 well plate

$ 49000 / Each of 1

ELISA Microplate Reader LMER-601

  • Plate Type: 96 well/48 well
  • Wavelength Range: 400 to 800nm
  • Indication Range: 0.000 to 4.000 OD
  • Test Capacity: 12 tests per plate
  • Resolution: 0.001A

$ 4462.5 / Each of 1

Microplate Reader LMRW-A101

  • Plate type: 96 well plate
  • Display: 6 ” LCD
  • Standard Wavelength: 405, 450, 492, 630 nm
  • Wavelength accuracy: ± 1 nm
  • Resolution: 0.001 Abs

$ 3675 / Each of 1

Microplate Reader LMMR-M102
  • Plate Type: 96 well/48 well
  • Wavelength Range: 400 to 800nm
  • Indication Range: 0.000 to 4.000 OD
  • Test Capacity: 12 tests per plate
  • Resolution: 0.001A

$ 3612.5 / Pack of 1

Microplate Reader LMMR-M103
  • Wavelength Range: 400nm to 630nm
  • Microplate Type: 96 well plate
  • Measure system: 8-channel optical system
  • Reading Range: 0.000 ~ 4.000 Abs
  • Bandwidth & Accuracy: 8nm ± 2nm

$ 3362.5 / Pack of 1

Microplate Reader LMMR-A200

  • Detection Modes: Fluorescence, Absorbance, Chemiluminescence
  • Microplate Compatibility: 6/12/24/48/96/384 Microplate
  • Excitation Range: 320 to 1000 nm
  • Excitation Filter: 355, 485,544nm
  • Emission Range: 360 to 800 nm

$ 36750 / Each of 1

Microplate Reader LMMR-A102

  • Wavelength Range: 200 to 1000 nm
  • Microplate Compatibility: 96-well plate, 8 × 12 format
  • Measurement Range: 0 to 4 Abs
  • Linear Range: 0 to 3 Abs, ± 2% (96-well plate)
  • Accuracy at 405 nm: ± 1% (0 to 3 Abs), ± 2% (3 to 4 Abs)

$ 7350 / Each of 1

Microplate Reader LMMR-A101

  • Wavelength Range: 380 to 1000 nm
  • Microplate Compatibility: 96-well plate, 8 × 12 format
  • Measurement Range: 0 to 4 Abs
  • Linear Range: 0 to 3 Abs, ± 2% (96-well plate)
  • Accuracy at 405 nm: ± 1% (0 to 3 Abs), ± 2% (3 to 4 Abs)

$ 15925 / Each of 1

ELISA Microplate Reader LMMR-M101
  • Plate Type: 96 well/48 well
  • Wavelength Range: 400 to 800nm
  • Indication Range: 0.000 to 4.000 OD
  • Test Capacity: 12 tests per plate
  • Resolution: 0.001A

$ 3250 / Each of 1

Microplate Reader LMMR-A201
  • Detection Modes: Fluorescence, Chemiluminescence
  • Microplate Compatibility: 6/12/24/48/96/384 Microplate
  • Excitation Wavelength Range: 320 to 1000 nm
  • Emission Wavelength Range: 360 to 800 nm
  • Wavelength Resolution: 1nm

$ 26950 / Each of 1

Microplate Reader LMRW-A102

  • Plate Formats: 96 and 384 wells
  • Detection Modes: Absorbance, fluorescence, luminescence
  • Absorbance Light Source: High-energy xenon flash lamp
  • Absorbance Detector: PD
  • Absorbance Wavelength Range: 200 to 1000nm, 1nm step

$ 32425 / Pack of 1

Microplate Reader LMMR-A103

  • Wavelength Range: 380 to 1000 nm
  • Microplate Compatibility: 96-well plate, 8 × 12 format
  • Measurement Range: 0 to 4 Abs
  • Linear Range: 0 to 3 Abs, ± 2% (96-well plate)
  • Accuracy at 405 nm: ± 1% (0 to 3 Abs), ± 2% (3 to 4 Abs)

$ 5512.5 / Each of 1

Microplate Reader LMMR-A100

  • Wavelength Range: 200 to 1000 nm
  • Microplate Compatibility: 96-well plate, 8 × 12 format
  • Measurement Range: 0 to 4 Abs
  • Linear Range: 0 to 3 Abs, ± 2% (96-well plate)
  • Accuracy at 405 nm: ± 1% (0 to 3 Abs), ± 2% (3 to 4 Abs)

$ 13475 / Each of 1

Microplate Reader LMMR-A300
  • Microplate Types: Supports 6 to 384 well plates; 96-well included
  • Light source: Xenon lamp
  • Temperature Control: RT +4 °C to 45 °C ± 0.5 °C at 37 °C
  • Dynamic Range: 0 to 4 OD range supported
  • Shaking: Linear and orbital shaking: Linear, annular, and double annular shaking modes available

$ 32000 / Each of 1

Frequently Asked Questions

1 What is a Microplate Reader?

A Microplate Reader is an apparatus designed to detect biological, chemical, or physical events within the wells of a microplate.

2 How does Microplate Reader work?

It works by using optical detection methods such as absorbance, fluorescence, or luminescence to measure reactions in each well of a microplate.

3 Why is Microplate Reader important in drug discovery?

It is important in drug discovery because it enables high-throughput screening, allowing researchers to analyze thousands of samples quickly and accurately.

4 Can Microplate Reader be used for kinetic assays?

It is used for kinetic assays, allowing researchers to monitor changes in absorbance or fluorescence over time.

5 How is Microplate Reader used in ELISA assays?

It is used in ELISA assays to measure absorbance in microplate wells, quantifying the presence of specific proteins or antigens based on colorimetric changes.

6 Can Microplate Reader be used for cytotoxicity assays?

It can be used for cytotoxicity assays by detecting changes in absorbance or fluorescence that reflect cell viability or membrane integrity.

7 Can Microplate Reader be used for bacterial growth studies?

It can be used for bacterial growth studies by continuously measuring optical density, allowing researchers to monitor growth curves over time.

8 Can Microplate Reader be used for hormone detection?

It is commonly used for hormone detection in ELISA- or luminescence-based immunoassays, enabling accurate quantification of hormone levels in biological samples.

9 Can Microplate Reader be used in food safety testing?

It is used in food safety testing to detect contaminants, toxins, or pathogens via immunoassays or enzymatic reactions in microplate formats.

10 How is Microplate Reader used in environmental monitoring?

It is used in environmental monitoring for detecting pollutants, heavy metals, or microbial content using biochemical assays in water and soil samples.