Get Quote

Contact us now to receive a detailed quotation.

Need quick help? Chat with us on WhatsApp:

WhatsApp QR Code

OR

Microplate Reader LMMR-A300

Microplate Reader LMMR-A300 is compatible with microplates ranging from 6 to 384 wells, including standard 96-well plates. It is equipped with a xenon lamp it features precise temperature regulation. It supports multiple detection modes, including absorbance, fluorescence, and luminescence, with advanced capabilities. Our Microplate Reader is designed for medical, biological, and pharmaceutical research applications

Catalog Send Mail Whatsapp

Specifications

Microplate Types Supports 6 to 384 well plates; 96-well included
Light source Xenon lamp
Temperature Control RT +4 °C to 45 °C ± 0.5 °C at 37 °C
Dynamic Range 0 to 4 OD range supported
Shaking: Linear and orbital shaking Linear, annular, and double annular shaking modes available
Reading Speed Less than 15 s for 96-well plate fast mode
Precision CV
Accuracy ± (1.0% + 0.003Abs) at 0 to 2.0 Abs
Ratio accuracy Data precision supported
Wavelength selection Advanced monochromator system 200 to 1000 nm
Fully controlled by software (open/close) Supported via Reader It-II software
Absorbance Detector UV-silicon photodiode
Absorbance Wavelength 200 to 1000 nm
Absorbance Wavelength accuracy ±0.5 nm >315 nm, ±0.3 nm ≤315 nm
Wavelength reproducibility (Absorbance) ±0.5 nm >315 nm, ±0.3 nm ≤315 nm
LOD DNA low volume Low-volume detection supported
Fluorescence Detector PMT detector
Excitation and Emission wavelength EX 200 to 1000 nm; EM 270 to 850 nm
Fluorescence bottom reading sensitivity Detection limit as low as 5 amol/well
Fluorescence intensity bottom LOD Mono Supports low LOD
Fluorescence polarization sensitivity FP detection sensitivity 5 mP
Excitation bandwidth less than 5 nm ≤315 nm; 315 nm
Emission bandwidth less than 20 nm
Fluorescence Wavelength accuracy ±2.0 nm >315 nm; ±1.0 nm ≤315 nm
Fluorescence Wavelength Reproducibility ±1.0 nm >315 nm; ±0.5 nm ≤315 nm
Dimension 420 × 550 × 386 mm
Packaging Dimension 500 × 600 × 450 mm
Net Weight 33 Kg
Gross Weight 40 Kg

Pricing

Product Price Unit Action
Microplate Reader LMMR-A300 $ 32000 Each of 1

Features

  • Multi-mode detection

  • Temperature control

  • High sensitivity

  • Wide dynamic range

  • Fluorescence polarization

Applications

Microplate Reader LMMR-A300 is used for quantitative analysis of biomolecules and enzyme activity, and it is widely applied in medical, biological, and pharmaceutical research laboratories

Similar Products

Microplate Reader LMMR-M103

  • Wavelength Range: 400nm to 630nm
  • Microplate Type: 96 well plate
  • Measure system: 8-channel optical system
  • Reading Range: 0.000 ~ 4.000 Abs
  • Bandwidth & Accuracy: 8nm ± 2nm

$ 3362.5 / Pack of 1

Microplate Reader LMRW-A100

  • Plate type: 96 well plate
  • Standard Wavelength: 405, 450, 492, 630 nm
  • Wavelength accuracy: ± 1 nm
  • Resolution: 0.001 Abs
  • Reading speed (Single wavelength): 5 secs for 96 well plate

$ 49000 / Each of 1

Microplate Reader LMMR-A201

  • Detection Modes: Fluorescence, Chemiluminescence
  • Microplate Compatibility: 6/12/24/48/96/384 Microplate
  • Excitation Wavelength Range: 320 to 1000 nm
  • Emission Wavelength Range: 360 to 800 nm
  • Wavelength Resolution: 1nm

$ 26950 / Each of 1

Microplate Reader LMMR-M104
  • Wavelength Range: 340 to 750nm
  • Filter Bandwidth: 8 to 10nm
  • Standard Filters: 405nm, 450nm, 492nm, 630nm
  • Filter: 8-bit filter wheel
  • Optical System: 13 channels

$ 3997.5 / Each of 1

Microplate Reader LMMR-A102
  • Wavelength Range: 200 to 1000 nm
  • Microplate Compatibility: 96-well plate, 8 × 12 format
  • Measurement Range: 0 to 4 Abs
  • Linear Range: 0 to 3 Abs, ± 2% (96-well plate)
  • Accuracy at 405 nm: ± 1% (0 to 3 Abs), ± 2% (3 to 4 Abs)

$ 7350 / Each of 1

ELISA Microplate Reader LMER-601

  • Plate Type: 96 well/48 well
  • Wavelength Range: 400 to 800nm
  • Indication Range: 0.000 to 4.000 OD
  • Test Capacity: 12 tests per plate
  • Resolution: 0.001A

$ 4462.5 / Each of 1

Microplate Reader LMRW-A101

  • Plate type: 96 well plate
  • Display: 6 ” LCD
  • Standard Wavelength: 405, 450, 492, 630 nm
  • Wavelength accuracy: ± 1 nm
  • Resolution: 0.001 Abs

$ 3675 / Each of 1

Microplate Reader LMRW-A102

  • Plate Formats: 96 and 384 wells
  • Detection Modes: Absorbance, fluorescence, luminescence
  • Absorbance Light Source: High-energy xenon flash lamp
  • Absorbance Detector: PD
  • Absorbance Wavelength Range: 200 to 1000nm, 1nm step

$ 32425 / Pack of 1

ELISA Microplate Reader LMMR-M101
  • Plate Type: 96 well/48 well
  • Wavelength Range: 400 to 800nm
  • Indication Range: 0.000 to 4.000 OD
  • Test Capacity: 12 tests per plate
  • Resolution: 0.001A

$ 3250 / Each of 1

Microplate Reader LMMR-M102
  • Plate Type: 96 well/48 well
  • Wavelength Range: 400 to 800nm
  • Indication Range: 0.000 to 4.000 OD
  • Test Capacity: 12 tests per plate
  • Resolution: 0.001A

$ 3612.5 / Pack of 1

Microplate Reader LMMR-A200

  • Detection Modes: Fluorescence, Absorbance, Chemiluminescence
  • Microplate Compatibility: 6/12/24/48/96/384 Microplate
  • Excitation Range: 320 to 1000 nm
  • Excitation Filter: 355, 485,544nm
  • Emission Range: 360 to 800 nm

$ 36750 / Each of 1

Microplate Reader LMMR-A101

  • Wavelength Range: 380 to 1000 nm
  • Microplate Compatibility: 96-well plate, 8 × 12 format
  • Measurement Range: 0 to 4 Abs
  • Linear Range: 0 to 3 Abs, ± 2% (96-well plate)
  • Accuracy at 405 nm: ± 1% (0 to 3 Abs), ± 2% (3 to 4 Abs)

$ 15925 / Each of 1

Microplate Reader LMMR-A103

  • Wavelength Range: 380 to 1000 nm
  • Microplate Compatibility: 96-well plate, 8 × 12 format
  • Measurement Range: 0 to 4 Abs
  • Linear Range: 0 to 3 Abs, ± 2% (96-well plate)
  • Accuracy at 405 nm: ± 1% (0 to 3 Abs), ± 2% (3 to 4 Abs)

$ 5512.5 / Each of 1

Microplate Reader LMMR-A100
  • Wavelength Range: 200 to 1000 nm
  • Microplate Compatibility: 96-well plate, 8 × 12 format
  • Measurement Range: 0 to 4 Abs
  • Linear Range: 0 to 3 Abs, ± 2% (96-well plate)
  • Accuracy at 405 nm: ± 1% (0 to 3 Abs), ± 2% (3 to 4 Abs)

$ 13475 / Each of 1

Frequently Asked Questions

1 What is a Microplate Reader?

A Microplate Reader is an apparatus designed to detect biological, chemical, or physical events within the wells of a microplate.

2 How does Microplate Reader work?

It works by using optical detection methods such as absorbance, fluorescence, or luminescence to measure reactions in each well of a microplate.

3 Why is Microplate Reader important in drug discovery?

It is important in drug discovery because it enables high-throughput screening, allowing researchers to analyze thousands of samples quickly and accurately.

4 Can Microplate Reader be used for kinetic assays?

It is used for kinetic assays, allowing researchers to monitor changes in absorbance or fluorescence over time.

5 How is Microplate Reader used in ELISA assays?

It is used in ELISA assays to measure absorbance in microplate wells, quantifying the presence of specific proteins or antigens based on colorimetric changes.

6 Can Microplate Reader be used for cytotoxicity assays?

It can be used for cytotoxicity assays by detecting changes in absorbance or fluorescence that reflect cell viability or membrane integrity.

7 Can Microplate Reader be used for bacterial growth studies?

It can be used for bacterial growth studies by continuously measuring optical density, allowing researchers to monitor growth curves over time.

8 Can Microplate Reader be used for hormone detection?

It is commonly used for hormone detection in ELISA- or luminescence-based immunoassays, enabling accurate quantification of hormone levels in biological samples.

9 Can Microplate Reader be used in food safety testing?

It is used in food safety testing to detect contaminants, toxins, or pathogens via immunoassays or enzymatic reactions in microplate formats.

10 How is Microplate Reader used in environmental monitoring?

It is used in environmental monitoring for detecting pollutants, heavy metals, or microbial content using biochemical assays in water and soil samples.