Get Quote

Contact us now to receive a detailed quotation.

Microplate Reader LMMR-A103

Microplate Reader LMMR-A103 offers wide measurement range of 0 to 4 Abs, enabling efficient analysis across low and high absorbance levels. Equipped with advanced optical components, it delivers reliable and consistent absorbance measurements. Integrated with incubation and shaking system to provide optimal assay conditions. Featuring long-life tungsten light source, it ensures stable optical performance. Our Microplate Reader with intuitive controls simplifies workflows, delivering smooth and streamlined operation.

Catalog Send Mail Whatsapp

Specifications

Wavelength Range 380 to 1000 nm
Microplate Compatibility 96-well plate, 8 × 12 format
Measurement Range 0 to 4 Abs
Linear Range 0 to 3 Abs, ± 2% (96-well plate)
Accuracy at 405 nm ± 1% (0 to 3 Abs), ± 2% (3 to 4 Abs)
Precision at 405 nm CV less than or equal to 0.2% (0 to 3 Abs), CV less than or equal to 1.0% (3 to 4 Abs)
Resolution 0.001 Abs
Speed 12s
Optical Path 12-channel detection with 1 real-time reference channel
Filter System 405, 450, 492, 600, 650, 260, 280 nm
Light Source Tungsten lamp
Detection Modes Single wavelength, dual wavelength
Shaker 24 hr operation, continuous or interval
Incubation RT +3 ℃ to 45 ℃
Interface 2 × USB ports
Dimension 38×31×31cm
Weight 15Kg

Pricing

Product Price Unit Action
Microplate Reader LMMR-A103 $ 5512.5 Each of 1

Features

Built-in tablet interface

Broad wavelength coverage

Rapid detection

Dual USB connectivity

Multiple calculation functions

Applications

Microplate Reader LMMR-A103 is employed in ELISA, MTT analysis, enzyme activity assays, cell viability and cytotoxicity testing, endotoxin detection, and drug screening for rapid and reliable quantitative analysis.

Similar Products

Microplate Reader LMRW-A101

  • Plate type: 96 well plate
  • Display: 6 ” LCD
  • Standard Wavelength: 405, 450, 492, 630 nm
  • Wavelength accuracy: ± 1 nm
  • Resolution: 0.001 Abs

$ 3675 / Each of 1

ELISA Microplate Reader LMMR-M101

  • Plate Type: 96 well/48 well
  • Wavelength Range: 400 to 800nm
  • Indication Range: 0.000 to 4.000 OD
  • Test Capacity: 12 tests per plate
  • Resolution: 0.001A

$ 4050 / Each of 1

Microplate Reader LMMR-A201

  • Detection Modes: Fluorescence, Chemiluminescence
  • Microplate Compatibility: 6/12/24/48/96/384 Microplate
  • Excitation Wavelength Range: 320 to 1000 nm
  • Emission Wavelength Range: 360 to 800 nm
  • Wavelength Resolution: 1nm

$ 26950 / Each of 1

Microplate Reader LMMR-A102
  • Wavelength Range: 200 to 1000 nm
  • Microplate Compatibility: 96-well plate, 8 × 12 format
  • Measurement Range: 0 to 4 Abs
  • Linear Range: 0 to 3 Abs, ± 2% (96-well plate)
  • Accuracy at 405 nm: ± 1% (0 to 3 Abs), ± 2% (3 to 4 Abs)

$ 7350 / Each of 1

Microplate Reader LMMR-M102
  • Plate Type: 96 well/48 well
  • Wavelength Range: 400 to 800nm
  • Indication Range: 0.000 to 4.000 OD
  • Test Capacity: 12 tests per plate
  • Resolution: 0.001A

$ 4412.5 / Pack of 1

Microplate Reader LMMR-M103

  • Wavelength Range: 400nm to 630nm
  • Microplate Type: 96 well plate
  • Measure system: 8-channel optical system
  • Reading Range: 0.000 ~ 4.000 Abs
  • Bandwidth & Accuracy: 8nm ± 2nm

$ 3362.5 / Pack of 1

Microplate Reader LMRW-A100

  • Plate type: 96 well plate
  • Standard Wavelength: 405, 450, 492, 630 nm
  • Wavelength accuracy: ± 1 nm
  • Resolution: 0.001 Abs
  • Reading speed (Single wavelength): 5 secs for 96 well plate

$ 49000 / Each of 1

Microplate Reader LMRW-A102

  • Plate Formats: 96 and 384 wells
  • Detection Modes: Absorbance, fluorescence, luminescence
  • Absorbance Light Source: High-energy xenon flash lamp
  • Absorbance Detector: PD
  • Absorbance Wavelength Range: 200 to 1000nm, 1nm step

$ 32425 / Pack of 1

Microplate Reader LMMR-A101
  • Wavelength Range: 380 to 1000 nm
  • Microplate Compatibility: 96-well plate, 8 × 12 format
  • Measurement Range: 0 to 4 Abs
  • Linear Range: 0 to 3 Abs, ± 2% (96-well plate)
  • Accuracy at 405 nm: ± 1% (0 to 3 Abs), ± 2% (3 to 4 Abs)

$ 15925 / Each of 1

Microplate Reader LMMR-A200
  • Detection Modes: Fluorescence, Absorbance, Chemiluminescence
  • Microplate Compatibility: 6/12/24/48/96/384 Microplate
  • Excitation Range: 320 to 1000 nm
  • Excitation Filter: 355, 485,544nm
  • Emission Range: 360 to 800 nm

$ 36750 / Each of 1

ELISA Microplate Reader LMER-601

  • Plate Type: 96 well/48 well
  • Wavelength Range: 400 to 800nm
  • Indication Range: 0.000 to 4.000 OD
  • Test Capacity: 12 tests per plate
  • Resolution: 0.001A

$ 4462.5 / Each of 1

Microplate Reader LMMR-M104

  • Wavelength Range: 340 to 750nm
  • Filter Bandwidth: 8 to 10nm
  • Standard Filters: 405nm, 450nm, 492nm, 630nm
  • Filter: 8-bit filter wheel
  • Optical System: 13 channels

$ 3997.5 / Each of 1

Microplate Reader LMMR-A100

  • Wavelength Range: 200 to 1000 nm
  • Microplate Compatibility: 96-well plate, 8 × 12 format
  • Measurement Range: 0 to 4 Abs
  • Linear Range: 0 to 3 Abs, ± 2% (96-well plate)
  • Accuracy at 405 nm: ± 1% (0 to 3 Abs), ± 2% (3 to 4 Abs)

$ 13475 / Each of 1

Frequently Asked Questions

1 What is a Microplate Reader?

A Microplate Reader is an apparatus designed to detect biological, chemical, or physical events within the wells of a microplate.

2 How does Microplate Reader work?

It works by using optical detection methods such as absorbance, fluorescence, or luminescence to measure reactions in each well of a microplate.

3 Why is Microplate Reader important in drug discovery?

It is important in drug discovery because it enables high-throughput screening, allowing researchers to analyze thousands of samples quickly and accurately.

4 Can Microplate Reader be used for kinetic assays?

It is used for kinetic assays, allowing researchers to monitor changes in absorbance or fluorescence over time.

5 How is Microplate Reader used in ELISA assays?

It is used in ELISA assays to measure absorbance in microplate wells, quantifying the presence of specific proteins or antigens based on colorimetric changes.

6 Can Microplate Reader be used for cytotoxicity assays?

It can be used for cytotoxicity assays by detecting changes in absorbance or fluorescence that reflect cell viability or membrane integrity.

7 Can Microplate Reader be used for bacterial growth studies?

It can be used for bacterial growth studies by continuously measuring optical density, allowing researchers to monitor growth curves over time.

8 Can Microplate Reader be used for hormone detection?

It is commonly used for hormone detection in ELISA- or luminescence-based immunoassays, enabling accurate quantification of hormone levels in biological samples.

9 Can Microplate Reader be used in food safety testing?

It is used in food safety testing to detect contaminants, toxins, or pathogens via immunoassays or enzymatic reactions in microplate formats.

10 How is Microplate Reader used in environmental monitoring?

It is used in environmental monitoring for detecting pollutants, heavy metals, or microbial content using biochemical assays in water and soil samples.