Horizontal Autoclave LMHA-B102

Horizontal Autoclave LMHA-B102 supports 360 litres volume. Its vacuum drying function with 6-level cold air emission ensures post-sterilization drying and cooling. Its reservation function and multi-level access control, enhance operational convenience. It features safety interlock to prevent door access during process, offering protection. Our Horizontal Autoclave is ideal for decontamination and sterilization of biological waste, media, instruments.

Catalog Send Mail Whatsapp

Specifications

Volume 360 L
Temperature Range 105°C to 135°C
Pre-Configured Programs 9 (Sterilization) + 3 (Melting and Insulation Programs)
Power Consumption 15.5 kW
Power Supply 380 V, 50 Hz
Internal Dimension Ø700×1050 mm
Housing Dimension 1000 × 1515 × 1803 mm
Package Dimension 1600 × 1000 × 2000 mm
Net Weight 650 kg
Gross Weight 700 kg

Pricing

Product Price Unit Action
Horizontal Autoclave LMHA-B102 $ 14500 Each of 1

Features

7-inch touch screen 

Spoke door structure 

Self-expanding seal ring

Water level detection

Three-level exhaust settings

Steam generator and water pump

Optional Accessories

Model No

Accessory

LMHA-B102-S1

Stainless steel housing

Applications

Horizontal Autoclave LMHA-B102 is ideal for decontaminating and sterilizing of biological waste, culture media, instruments, and labware in fields such as healthcare, microbiology, biotechnology, pharmaceuticals, and research.

Lab Autoclave with vacuum drying function
Lab Autoclave with vacuum drying function

Similar Products

Horizontal Autoclave LMHA-A400

  • Capacity: 150 L
  • Temperature Range: 134 °C
  • Pressure: 0.22 MPa
  • Time Range: 0 to 60 min
  • Drying Time: 0 to 60 min

$ 7800 / Each of 1

Horizontal Autoclave LMHA-A202

  • Capacity: 280 L
  • Temperature Range: 134 °C
  • Pressure: 0.22 MPa
  • Time Range: 0 to 60 min
  • Drying Time: 0 to 60 min

$ 6525 / Each of 1

Horizontal Autoclave LMHA-A204

  • Capacity: 500 L
  • Temperature Range: 134 °C
  • Pressure: 0.22 MPa
  • Time Range: 0 to 60 min
  • Drying Time: 0 to 60 min

$ 8612.5 / Pack of 1

Horizontal Autoclave LMHA-B105
  • Volume: 500 L
  • Temperature Range: 105°C to 135°C
  • Pre-Configured Programs: 9 (Sterilization) + 3 (Melting and Insulation Programs)
  • Power Consumption: 19.1 kW
  • Power Supply: 380 V, 50 Hz

$ 16875 / Each of 1

Horizontal Autoclave LMHA-A201
  • Capacity: 200 L
  • Temperature Range: 134 °C
  • Pressure: 0.22 MPa
  • Time Range: 0 to 60 min
  • Drying Time: 0 to 60 min

$ 5925 / Pack of 1

Horizontal Autoclave LMHA-A101

  • Capacity: 200 L
  • Temperature Range: 50 °C to 134 °C
  • Pressure: 0.217 Mpa
  • Time Range: 0 to 99 hr
  • Power: 7.5 kW

$ 8912.5 / Pack of 1

Horizontal Autoclave LMHA-A500

  • Capacity: 150 L
  • Temperature Range: 134 °C
  • Pressure: 0.22 MPa
  • Time Range: 0 - 99 min
  • Drying Time: 0 - 99 min

$ 9712.5 / Each of 1

Horizontal Autoclave LMHA-A302

  • Capacity: 280 L
  • Temperature Range: 134 °C
  • Pressure: 0.22 MPa
  • Time Range: 0 to 90 min
  • Drying Time: 0 to 90 min

$ 9025 / Each of 1

Horizontal Autoclave LMHA-A203
  • Capacity: 400 L
  • Temperature Range: 134 °C
  • Pressure: 0.22 MPa
  • Time Range: 0 to 60 min
  • Drying Time: 0 to 60 min

$ 4275 / Each of 1

Horizontal Autoclave LMHA-A103
  • Chamber Volume: 100 L
  • Temperature Range: 115°C to 134 °C
  • Working Temperature: 134 ℃
  • pressure control range: 0.07-0.22Mpa
  • Working Pressure: 0.22Mpa

$ 5062.5 / Each of 1

Horizontal Autoclave LMHA-A402

  • Capacity: 280 L
  • Temperature Range: 134 °C
  • Pressure: 0.22 MPa
  • Time Range: 0 to 60 min
  • Drying Time: 0 to 60 min

$ 13225 / Each of 1

Horizontal Autoclave LMHA-A200

  • Capacity: 150 L
  • Temperature Range: 134 °C
  • Pressure: 0.22 MPa
  • Time Range: 0 to 60 min
  • Drying Time: 0 to 60 min

$ 5325 / Pack of 1

Horizontal Autoclave LMHA-A501

  • Capacity: 200 L
  • Temperature Range: 134 °C
  • Pressure: 0.22 MPa
  • Time Range: 0 - 99 min
  • Drying Time: 0 - 99 min

$ 11362.5 / Each of 1

Horizontal Autoclave LMHA-B104
  • Volume: 500 L
  • Temperature Range: 105°C to 135°C
  • Pre-Configured Programs: 9 (Sterilization) + 3 (Melting and Insulation Programs)
  • Power Consumption: 17 kW
  • Power Supply: 380 V, 50 Hz

$ 15250 / Each of 1

Horizontal Autoclave LMHA-A100
  • Capacity: 120 L
  • Temperature Range: 50 °C to 134 °C
  • Pressure: 0.217 Mpa
  • Time Range: 0 to 99 hr
  • Power: 7.5 kW

$ 6612.5 / Pack of 1

Frequently Asked Questions

1 What is a Horizontal Autoclave LMHA-B102?

Horizontal Autoclave LMHA-B102 is a large-capacity, steam-based sterilizer designed for sterilizing lab instruments, waste in hospitals, research labs and biotech facilities.

2 How does Horizontal Autoclave LMHA-B102 work?

Horizontal Autoclave LMHA-B102 works on the principle of moist heat sterilization using pressurized steam.

3 Can biological waste be sterilized using Horizontal Autoclave LMHA-B102?

Horizontal Autoclave LMHA-B102 is designed to safely sterilize biological waste, preventing contamination and ensuring biosafety compliance.

4 How does Horizontal Autoclave LMHA-B102 support infection control protocols?

Horizontal Autoclave LMHA-B102 ensures effective sterilization of contaminated materials, supporting infection control in medical and research settings.

5 Can Horizontal Autoclave LMHA-B102 be used in food testing laboratories?

Horizontal Autoclave LMHA-B102 is suitable for sterilizing tools and media used in microbiological testing in food and beverage laboratories.

6 How does Horizontal Autoclave LMHA-B102 benefit tissue culture laboratories?

Horizontal Autoclave LMHA-B102 sterilizes glassware, media, and instruments essential for maintaining aseptic conditions in plant and animal tissue culture laboratories.

7 Can Horizontal Autoclave LMHA-B102 be used in research on antibiotic resistance?

Horizontal Autoclave LMHA-B102 is essential in antibiotic resistance studies for sterilizing bacterial cultures and contaminated waste.

8 Is Horizontal Autoclave LMHA-B102 useful in pathology laboratories?

Horizontal Autoclave LMHA-B102 is used in pathology laboratories to sterilize biopsy tools, slides, and contaminated disposables.

9 Can Horizontal Autoclave LMHA-B102 be used in environmental testing laboratories?

Horizontal Autoclave LMHA-B102 is used to sterilize sampling tools and culture media for water, soil, and air microbial testing.

10 How does Horizontal Autoclave LMHA-B102 support forensic science laboratories?

Horizontal Autoclave LMHA-B102 sterilizes tools and disposables used in DNA and bio-evidence handling to prevent cross-contamination.

11 What is a Horizontal Autoclave?

A Horizontal Autoclave is an apparatus designed to use high-pressure steam in a horizontally oriented chamber to sterilize equipment and materials.

12 How does a Horizontal Autoclave work?

It works by using high-pressure steam to heat and sterilize materials inside a sealed chamber.

13 Can Horizontal Autoclave be used for both solid and liquid sterilization?

It is versatile and can sterilize both solid items and liquids.

14 What materials can be sterilized in Horizontal Autoclave?

It can sterilize a variety of materials such as surgical instruments, glassware, laboratory tools, textiles, plastic containers, media for microbiological cultures and food products.

15 What is the difference between a Horizontal and a Vertical Autoclave?

A Horizontal Autoclave has a horizontally aligned chamber, making it easier to load and unload, whereas a Vertical Autoclave has a vertical chamber for smaller items.

16 What kind of maintenance does Horizontal Autoclave require?

Regular maintenance includes proper cleaning, checking of seals and valves, calibrating sensors, and inspecting for wear to ensure efficient and safe functioning.

17 Can Horizontal Autoclave be used in veterinary practices?

It can be used in veterinary practices.

18 Can Horizontal Autoclave be used for research involving pathogens?

It is critical for inactivating dangerous pathogens before disposal or reuse.

19 What is a sterilization hold time in Horizontal Autoclave?

It is the period during which the load is maintained at the sterilization temperature to ensure effective microbial kill.

20 Can Horizontal Autoclave be used to sterilize syringes and glass vials?

It is commonly used to sterilize empty syringes, glass vials and other containers before filling in pharmaceutical environments.