Get Quote

Contact us now to receive a detailed quotation.

Need quick help? Chat with us on WhatsApp:

WhatsApp QR Code

OR

Horizontal Autoclave LMHA-A402

Horizontal Autoclave LMHA-A402 is a top-loading and long-lasting autoclave that offers outstanding performance during sterilization and drying of laboratory applications. It features a storage capacity of 280 L that works within a temperature range of up to 40 °C to 134 °C. Enhanced with an LED panel, which enables simple control and a visual evaluation of operational characteristics.

Catalog Send Mail Whatsapp

Specifications

Capacity 280 L
Temperature Range 134 °C
Pressure 0.22 MPa
Time Range 0 to 60 min
Drying Time 0 to 60 min
Chamber Size φ 600 × 1000 mm
Sterilizing Temperature 40 °C - 134 °C
Power 12 kW
Voltage 380 V ; 50 Hz
Heat Average ≤ ±2 °C
Dimension 1400 × 770 × 1780 mm
Net Weight 365 Kg
Gross Weight 465 Kg

Pricing

Product Price Unit Action
Horizontal Autoclave LMHA-A402 $ 13225 Each of 1

Features

Easy to view an LED screen for perfect observation of working parameters
Structured with a unique grease-free stainless-steel chamber that ensures long-term usability
Improved with self-locking door to prevent unauthorized access of a user for sample safety
Equipped with an alarm module that triggers alert warnings against overloading and overheating
Configured with fully automatic features that provide better working conditions 
Easily adjustable with effortless handling
Flexible and cost-effective maintenance with high reliability and durability
Hygienic cleaning with safety and sanitation

Applications

It is extensively used to sterilize surgical equipment, laboratory instruments, pharmaceutical items, and other materials.

Similar Products

Horizontal Autoclave LMHA-A301

  • Capacity: 200 L
  • Temperature Range: 134 °C
  • Pressure: 0.22 MPa
  • Time Range: 0 to 90 min
  • Drying Time: 0 to 90 min

$ 7687.5 / Each of 1

Horizontal Autoclave LMHA-A203

  • Capacity: 400 L
  • Temperature Range: 134 °C
  • Pressure: 0.22 MPa
  • Time Range: 0 to 60 min
  • Drying Time: 0 to 60 min

$ 4275 / Each of 1

Horizontal Autoclave LMHA-A401

  • Capacity: 200 L
  • Temperature Range: 134 °C
  • Pressure: 0.22 MPa
  • Time Range: 0 to 60 min
  • Drying Time: 0 to 60 min

$ 8950 / Each of 1

Horizontal Autoclave LMHA-A200
  • Capacity: 150 L
  • Temperature Range: 134 °C
  • Pressure: 0.22 MPa
  • Time Range: 0 to 60 min
  • Drying Time: 0 to 60 min

$ 5325 / Pack of 1

Horizontal Autoclave LMHA-A102
  • Capacity: 300 L
  • Temperature Range: 50 °C to 134 °C
  • Pressure: 0.217 Mpa
  • Time Range: 0 to 99 hr
  • Power: 7.5 kW

$ 11087.5 / Pack of 1

Horizontal Autoclave LMHA-A601

  • Volume: 146 L
  • Chamber Dimension (W×D×H): 420×420×830 mm
  • Power Consumption: 18 KW
  • Power Supply: 380V, 50 Hz
  • External Size (W×D×H): 1290×1680×1100 mm

$ 36862.5 / Each of 1

Horizontal Autoclave LMHA-A701

  • Capacity: 800 L
  • Door type: Automatic vertical sliding door
  • Vessel design life: Internal Tank: S30408 Stainless Steel, Jacket: Q245R, Life: 10 years, Sterilization cycles: 20000Inner Liner: 316 L Stainless Steel, Jacket: S30408, Life:15 years, Sterilization cycles: 30000
  • Steam consumption: 45 Kg/C
  • Design Pressure of Inner Chamber: -0.1 to 0.3 MPa

$ 26237.5 / Pack of 1

Horizontal Autoclave LMHA-B101

  • Volume: 280 L
  • Temperature Range: 105°C to 135°C
  • Pre-Configured Programs: 9 (Sterilization) + 3 (Melting and Insulation Programs)
  • Power Consumption: 14.6 kW
  • Power Supply: 380 V, 50 Hz

$ 13875 / Each of 1

Horizontal Autoclave LMHA-A103
  • Chamber Volume: 100 L
  • Temperature Range: 115°C to 134 °C
  • Working Temperature: 134 ℃
  • pressure control range: 0.07-0.22Mpa
  • Working Pressure: 0.22Mpa

$ 5062.5 / Each of 1

Horizontal Autoclave LMHA-A403
  • Capacity: 400 L
  • Temperature Range: 134 °C
  • Pressure: 0.22 MPa
  • Time Range: 0 to 60 min
  • Drying Time: 0 to 60 min

$ 18225 / Each of 1

Horizontal Autoclave LMHA-B103

  • Volume: 360 L
  • Temperature Range: 105°C to 135°C
  • Pre-Configured Programs: 9 (Sterilization) + 3 (Melting and Insulation Programs)
  • Power Consumption: 17.6 kW
  • Power Supply: 380 V, 50 Hz

$ 16000 / Each of 1

Horizontal Autoclave LMHA-B102

  • Volume: 360 L
  • Temperature Range: 105°C to 135°C
  • Pre-Configured Programs: 9 (Sterilization) + 3 (Melting and Insulation Programs)
  • Power Consumption: 15.5 kW
  • Power Supply: 380 V, 50 Hz

$ 14500 / Each of 1

Horizontal Autoclave LMHA-A202

  • Capacity: 280 L
  • Temperature Range: 134 °C
  • Pressure: 0.22 MPa
  • Time Range: 0 to 60 min
  • Drying Time: 0 to 60 min

$ 6525 / Each of 1

Horizontal Autoclave LMHA-A501
  • Capacity: 200 L
  • Temperature Range: 134 °C
  • Pressure: 0.22 MPa
  • Time Range: 0 - 99 min
  • Drying Time: 0 - 99 min

$ 11362.5 / Each of 1

Horizontal Autoclave LMHA-A500
  • Capacity: 150 L
  • Temperature Range: 134 °C
  • Pressure: 0.22 MPa
  • Time Range: 0 - 99 min
  • Drying Time: 0 - 99 min

$ 9712.5 / Each of 1

Frequently Asked Questions

1 What is a Horizontal Autoclave LMHA-A402?

A Horizontal Autoclave LMHA-A402 is a fully automatic steam sterilizer used to safely sterilize medical, laboratory, and industrial equipment.

2 How does Horizontal Autoclave LMHA-A402 work?

Horizontal Autoclave LMHA-A402 works on the principle of moist heat sterilization using pressurized steam.

3 What role does Horizontal Autoclave LMHA-A402 play in food testing laboratories?

Horizontal Autoclave LMHA-A402 plays a key role in food testing labs by sterilizing sample containers and equipment to ensure accurate microbiological testing.

4 How is Horizontal Autoclave LMHA-A402 utilized in nanotechnology research?

Horizontal Autoclave LMHA-A402 is utilized in nanotechnology research to sterilize sensitive lab equipment, preventing nanoscale contamination.

5 Does Horizontal Autoclave LMHA-A402 support biosafety laboratories?

Horizontal Autoclave LMHA-A402 supports biosafety labs by safely sterilizing materials exposed to hazardous biological agents, ensuring laboratory safety.

6 How does Horizontal Autoclave LMHA-A402 contribute to environmental testing labs?

Horizontal Autoclave LMHA-A402 contributes by sterilizing sampling tools and containers used in environmental microbiology and contamination assessments.

7 Can Horizontal Autoclave LMHA-A402 be used in forensic laboratories?

Horizontal Autoclave LMHA-A402 is used in forensic labs to sterilize tools and evidence containers, preventing contamination during analysis.

8 How is Horizontal Autoclave LMHA-A402 used in water treatment laboratories?

Horizontal Autoclave LMHA-A402 sterilizes sampling bottles and filtration equipment used in water quality analysis.

9 How does Horizontal Autoclave LMHA-A402 help in biotechnology labs?

Horizontal Autoclave LMHA-A402 helps biotechnology labs by sterilizing culture media, lab instruments, and bioreactor components.

10 What is the use of Horizontal Autoclave LMHA-A402 in cell biology research?

Horizontal Autoclave LMHA-A402 is used in cell biology labs to sterilize flasks, pipettes, and growth media critical for cell culture experiments.

11 What is a Horizontal Autoclave?

A Horizontal Autoclave is an apparatus designed to use high-pressure steam in a horizontally oriented chamber to sterilize equipment and materials.

12 How does a Horizontal Autoclave work?

It works by using high-pressure steam to heat and sterilize materials inside a sealed chamber.

13 Can Horizontal Autoclave be used for both solid and liquid sterilization?

It is versatile and can sterilize both solid items and liquids.

14 What materials can be sterilized in Horizontal Autoclave?

It can sterilize a variety of materials such as surgical instruments, glassware, laboratory tools, textiles, plastic containers, media for microbiological cultures and food products.

15 What is the difference between a Horizontal and a Vertical Autoclave?

A Horizontal Autoclave has a horizontally aligned chamber, making it easier to load and unload, whereas a Vertical Autoclave has a vertical chamber for smaller items.

16 What kind of maintenance does Horizontal Autoclave require?

Regular maintenance includes proper cleaning, checking of seals and valves, calibrating sensors, and inspecting for wear to ensure efficient and safe functioning.

17 Can Horizontal Autoclave be used in veterinary practices?

It can be used in veterinary practices.

18 Can Horizontal Autoclave be used for research involving pathogens?

It is critical for inactivating dangerous pathogens before disposal or reuse.

19 What is a sterilization hold time in Horizontal Autoclave?

It is the period during which the load is maintained at the sterilization temperature to ensure effective microbial kill.

20 Can Horizontal Autoclave be used to sterilize syringes and glass vials?

It is commonly used to sterilize empty syringes, glass vials and other containers before filling in pharmaceutical environments.