Horizontal Autoclave LMHA-B105

Horizontal Autoclave LMHA-B105 offers large capacity of 500 litres. Equipped with multi-level access control and advanced monitoring for secure and intelligent system management. Its integrated steam generator and pump with water level detection ensures uninterrupted, safe operation. It features customizable exhaust settings with reservation function for process control. Our Horizontal Autoclave is suitable for sterilization of bulk equipment, laboratory glassware, and culture media.

Catalog Send Mail Whatsapp

Specifications

Volume 500 L
Temperature Range 105°C to 135°C
Pre-Configured Programs 9 (Sterilization) + 3 (Melting and Insulation Programs)
Power Consumption 19.1 kW
Power Supply 380 V, 50 Hz
Internal Dimension Ø700×1450 mm
Housing Dimension 1000×1915×1803 mm
Package Dimension 2000×1026×2000 mm
Net Weight 670 kg
Gross Weight 720 kg

Pricing

Product Price Unit Action
Horizontal Autoclave LMHA-B105 $ 16875 Each of 1

Features

7-inch touch screen 

Self-expanding seal ring

Spoke door structure 

Safety interlock

Vacuum drying function

6-level cold air emission

Optional Accessories

Model No

Accessory

LMHA-B105-S1

Stainless steel housing

Applications

Horizontal Autoclave LMHA-B105 is ideal for hospitals, research laboratories, and food industries for sterilization of surgical instruments, glassware, and processing equipment for safety, hygiene, and contamination control.

Horizontal Autoclave with multi-level access control
Horizontal Autoclave with multi-level access control

Similar Products

Horizontal Autoclave LMHA-A302

  • Capacity: 280 L
  • Temperature Range: 134 °C
  • Pressure: 0.22 MPa
  • Time Range: 0 to 90 min
  • Drying Time: 0 to 90 min

$ 9025 / Each of 1

Horizontal Autoclave LMHA-A601

  • Volume: 146 L
  • Chamber Dimension (W×D×H): 420×420×830 mm
  • Power Consumption: 18 KW
  • Power Supply: 380V, 50 Hz
  • External Size (W×D×H): 1290×1680×1100 mm

$ 36862.5 / Each of 1

Horizontal Autoclave LMHA-A402

  • Capacity: 280 L
  • Temperature Range: 134 °C
  • Pressure: 0.22 MPa
  • Time Range: 0 to 60 min
  • Drying Time: 0 to 60 min

$ 13225 / Each of 1

Horizontal Autoclave LMHA-A701
  • Capacity: 800 L
  • Door type: Automatic vertical sliding door
  • Vessel design life: Internal Tank: S30408 Stainless Steel, Jacket: Q245R, Life: 10 years, Sterilization cycles: 20000Inner Liner: 316 L Stainless Steel, Jacket: S30408, Life:15 years, Sterilization cycles: 30000
  • Steam consumption: 45 Kg/C
  • Design Pressure of Inner Chamber: -0.1 to 0.3 MPa

$ 26237.5 / Pack of 1

Horizontal Autoclave LMHA-A103
  • Chamber Volume: 100 L
  • Temperature Range: 115°C to 134 °C
  • Working Temperature: 134 ℃
  • pressure control range: 0.07-0.22Mpa
  • Working Pressure: 0.22Mpa

$ 5062.5 / Each of 1

Horizontal Autoclave LMHA-B102

  • Volume: 360 L
  • Temperature Range: 105°C to 135°C
  • Pre-Configured Programs: 9 (Sterilization) + 3 (Melting and Insulation Programs)
  • Power Consumption: 15.5 kW
  • Power Supply: 380 V, 50 Hz

$ 14500 / Each of 1

Horizontal Autoclave LMHA-A100

  • Capacity: 120 L
  • Temperature Range: 50 °C to 134 °C
  • Pressure: 0.217 Mpa
  • Time Range: 0 to 99 hr
  • Power: 7.5 kW

$ 6612.5 / Pack of 1

Horizontal Autoclave LMHA-B103

  • Volume: 360 L
  • Temperature Range: 105°C to 135°C
  • Pre-Configured Programs: 9 (Sterilization) + 3 (Melting and Insulation Programs)
  • Power Consumption: 17.6 kW
  • Power Supply: 380 V, 50 Hz

$ 16000 / Each of 1

Horizontal Autoclave LMHA-A500
  • Capacity: 150 L
  • Temperature Range: 134 °C
  • Pressure: 0.22 MPa
  • Time Range: 0 - 99 min
  • Drying Time: 0 - 99 min

$ 9712.5 / Each of 1

Horizontal Autoclave LMHA-A102
  • Capacity: 300 L
  • Temperature Range: 50 °C to 134 °C
  • Pressure: 0.217 Mpa
  • Time Range: 0 to 99 hr
  • Power: 7.5 kW

$ 11087.5 / Pack of 1

Horizontal Autoclave LMHA-A204

  • Capacity: 500 L
  • Temperature Range: 134 °C
  • Pressure: 0.22 MPa
  • Time Range: 0 to 60 min
  • Drying Time: 0 to 60 min

$ 8612.5 / Pack of 1

Horizontal Autoclave LMHA-A400

  • Capacity: 150 L
  • Temperature Range: 134 °C
  • Pressure: 0.22 MPa
  • Time Range: 0 to 60 min
  • Drying Time: 0 to 60 min

$ 7800 / Each of 1

Horizontal Autoclave LMHA-B100

  • Volume: 280 L
  • Temperature Range: 105°C to 135°C
  • Pre-Configured Programs: 9 (Sterilization) + 3 (Melting and Insulation Programs)
  • Power Consumption: 12.5 kW
  • Power Supply: 380 V, 50 Hz

$ 12312.5 / Each of 1

Horizontal Autoclave LMHA-A403
  • Capacity: 400 L
  • Temperature Range: 134 °C
  • Pressure: 0.22 MPa
  • Time Range: 0 to 60 min
  • Drying Time: 0 to 60 min

$ 18225 / Each of 1

Horizontal Autoclave LMHA-A401
  • Capacity: 200 L
  • Temperature Range: 134 °C
  • Pressure: 0.22 MPa
  • Time Range: 0 to 60 min
  • Drying Time: 0 to 60 min

$ 8950 / Each of 1

Frequently Asked Questions

1 What is a Horizontal Autoclave LMHA-B105?

A Horizontal Autoclave LMHA-B105 is a front-loading autoclave used for steam sterilizing laboratory and medical equipment.

2 How does Horizontal Autoclave LMHA-B105 work?

Horizontal Autoclave LMHA-B105 works on the principle of steam sterilization using high-pressure saturated steam.

3 Can Horizontal Autoclave LMHA-B105 sterilize dental instruments?

Horizontal Autoclave LMHA-B105 is suitable for sterilizing dental instruments using appropriate sterilization cycles.

4 Can Horizontal Autoclave LMHA-B105 be used in research laboratories?

Horizontal Autoclave LMHA-B105 is used in research laboratories for sterilizing equipment and culture media.

5 Can Horizontal Autoclave LMHA-B105 be used for sterilizing pharmaceutical products?

Horizontal Autoclave LMHA-B105 is suitable for sterilizing pharmaceutical products under controlled cycle parameters.

6 Can Horizontal Autoclave LMHA-B105 be used in veterinary clinics?

Horizontal Autoclave LMHA-B105 is suitable for sterilizing veterinary surgical instruments and equipment.

7 Can Horizontal Autoclave LMHA-B105 sterilize biohazard waste before disposal?

Horizontal Autoclave LMHA-B105 is designed to effectively sterilize biohazard waste, making it safe for disposal.

8 Can Horizontal Autoclave LMHA-A105 be used in food testing laboratories?

Horizontal Autoclave LMHA-A105 is used in food testing laboratories to sterilize media, glassware, and tools involved in microbial testing of food products.

9 Can Horizontal Autoclave LMHA-B105 sterilize water samples?

Horizontal Autoclave LMHA-B105 sterilizes water samples for microbiological testing.

10 Can Horizontal Autoclave LMHA-B105 sterilize biohazardous waste from Biosafety Level laboratories?

Horizontal Autoclave LMHA-B105 effectively sterilizes biohazardous waste from Biosafety Level laboratories to prevent contamination.

11 What is a Horizontal Autoclave?

A Horizontal Autoclave is an apparatus designed to use high-pressure steam in a horizontally oriented chamber to sterilize equipment and materials.

12 How does a Horizontal Autoclave work?

It works by using high-pressure steam to heat and sterilize materials inside a sealed chamber.

13 Can Horizontal Autoclave be used for both solid and liquid sterilization?

It is versatile and can sterilize both solid items and liquids.

14 What materials can be sterilized in Horizontal Autoclave?

It can sterilize a variety of materials such as surgical instruments, glassware, laboratory tools, textiles, plastic containers, media for microbiological cultures and food products.

15 What is the difference between a Horizontal and a Vertical Autoclave?

A Horizontal Autoclave has a horizontally aligned chamber, making it easier to load and unload, whereas a Vertical Autoclave has a vertical chamber for smaller items.

16 What kind of maintenance does Horizontal Autoclave require?

Regular maintenance includes proper cleaning, checking of seals and valves, calibrating sensors, and inspecting for wear to ensure efficient and safe functioning.

17 Can Horizontal Autoclave be used in veterinary practices?

It can be used in veterinary practices.

18 Can Horizontal Autoclave be used for research involving pathogens?

It is critical for inactivating dangerous pathogens before disposal or reuse.

19 What is a sterilization hold time in Horizontal Autoclave?

It is the period during which the load is maintained at the sterilization temperature to ensure effective microbial kill.

20 Can Horizontal Autoclave be used to sterilize syringes and glass vials?

It is commonly used to sterilize empty syringes, glass vials and other containers before filling in pharmaceutical environments.