Horizontal Autoclave LMHA-A204 is a microprocessor-controlled unit that offers a capacity of 500L. It operates within temperature ranges from 40°C to 134°C ensuring thorough sterilization. Our autoclave is designed with an auto-drying function which removes residual moisture and maintains sterility. It is integrated with an LED display and provides an intuitive interface for monitoring parameters.

Catalog Send Mail Whatsapp

Specifications

Capacity 500 L
Temperature Range 134 °C
Pressure 0.22 MPa
Time Range 0 to 60 min
Drying Time 0 to 60 min
Chamber Size φ 700 x 1300 mm
Sterilizing Temperature 40 °C to134 °C
Heat Average ≤ ±2 °C
Power Consumption 18 kW
Power Supply 380 V ; 50 Hz
Dimension 1800 × 900 × 1820 mm
Net Weight 470 Kg
Gross Weight 580 Kg

Features

Crafted with stainless steel
Self-locking door
Equipped with audible & visual alarms
Self-diagnostic control system

Applications

Horizontal Autoclave provides efficient, reliable sterilization and is widely used in medical facilities, laboratories, pharmaceuticals, food and beverage industries.

Horizontal Autoclave LMHA-A204 Banner
Horizontal Autoclave LMHA-A204 Banner

Similar Products

Horizontal Autoclave LMHA-A403

  • Capacity: 400 L
  • Temperature Range: 134 °C
  • Pressure: 0.22 MPa
  • Time Range: 0 to 60 min
  • Drying Time: 0 to 60 min

Horizontal Autoclave LMHA-B102

  • Volume: 360 L
  • Temperature Range: 105°C to 135°C
  • Pre-Configured Programs: 9 (Sterilization) + 3 (Melting and Insulation Programs)
  • Power Consumption: 15.5 kW
  • Power Supply: 380 V, 50 Hz

Horizontal Autoclave LMHA-B103

  • Volume: 360 L
  • Temperature Range: 105°C to 135°C
  • Pre-Configured Programs: 9 (Sterilization) + 3 (Melting and Insulation Programs)
  • Power Consumption: 17.6 kW
  • Power Supply: 380 V, 50 Hz
Horizontal Autoclave LMHA-B104
  • Volume: 500 L
  • Temperature Range: 105°C to 135°C
  • Pre-Configured Programs: 9 (Sterilization) + 3 (Melting and Insulation Programs)
  • Power Consumption: 17 kW
  • Power Supply: 380 V, 50 Hz
Horizontal Autoclave LMHA-A601
  • Volume: 146 L
  • Chamber Dimension (W×D×H): 420×420×830 mm
  • Power Consumption: 18 KW
  • Power Supply: 380V, 50 Hz
  • External Size (W×D×H): 1290×1680×1100 mm

Horizontal Autoclave LMHA-A500

  • Capacity: 150 L
  • Temperature Range: 134 °C
  • Pressure: 0.22 MPa
  • Time Range: 0 - 99 min
  • Drying Time: 0 - 99 min

Horizontal Autoclave LMHA-A501

  • Capacity: 200 L
  • Temperature Range: 134 °C
  • Pressure: 0.22 MPa
  • Time Range: 0 - 99 min
  • Drying Time: 0 - 99 min

Horizontal Autoclave LMHA-A102

  • Capacity: 300 L
  • Temperature Range: 50 °C to 134 °C
  • Pressure: 0.217 Mpa
  • Time Range: 0 to 99 hr
  • Power: 7.5 kW
Horizontal Autoclave LMHA-B100
  • Volume: 280 L
  • Temperature Range: 105°C to 135°C
  • Pre-Configured Programs: 9 (Sterilization) + 3 (Melting and Insulation Programs)
  • Power Consumption: 12.5 kW
  • Power Supply: 380 V, 50 Hz
Horizontal Autoclave LMHA-A200
  • Capacity: 150 L
  • Temperature Range: 134 °C
  • Pressure: 0.22 MPa
  • Time Range: 0 to 60 min
  • Drying Time: 0 to 60 min

Horizontal Autoclave LMHA-B101

  • Volume: 280 L
  • Temperature Range: 105°C to 135°C
  • Pre-Configured Programs: 9 (Sterilization) + 3 (Melting and Insulation Programs)
  • Power Consumption: 14.6 kW
  • Power Supply: 380 V, 50 Hz

Horizontal Autoclave LMHA-A701

  • Capacity: 800 L
  • Door type: Automatic vertical sliding door
  • Vessel design life: Internal Tank: S30408 Stainless Steel, Jacket: Q245R, Life: 10 years, Sterilization cycles: 20000 Inner Liner: 316 L Stainless Steel, Jacket: S30408, Life:15 years, Sterilization cycles: 30000
  • Steam consumption: 45 Kg/C
  • Design Pressure of Inner Chamber: -0.1 to 0.3 MPa

Horizontal Autoclave LMHA-B105

  • Volume: 500 L
  • Temperature Range: 105°C to 135°C
  • Pre-Configured Programs: 9 (Sterilization) + 3 (Melting and Insulation Programs)
  • Power Consumption: 19.1 kW
  • Power Supply: 380 V, 50 Hz
Horizontal Autoclave LMHA-A203
  • Capacity: 400 L
  • Temperature Range: 134 °C
  • Pressure: 0.22 MPa
  • Time Range: 0 to 60 min
  • Drying Time: 0 to 60 min
Horizontal Autoclave LMHA-A502
  • Capacity: 280 L
  • Temperature Range: 134 °C
  • Pressure: 0.22 MPa
  • Time Range: 0 - 99 min
  • Drying Time: 0 - 99 min

Frequently Asked Questions

1 What is a Horizontal Autoclave?

A Horizontal Autoclave is an apparatus designed to use high-pressure steam in a horizontally oriented chamber to sterilize equipment and materials.

2 How does a Horizontal Autoclave work?

It works by using high-pressure steam to heat and sterilize materials inside a sealed chamber.

3 Can Horizontal Autoclave be used for both solid and liquid sterilization?

It is versatile and can sterilize both solid items and liquids.

4 What materials can be sterilized in Horizontal Autoclave?

It can sterilize a variety of materials such as surgical instruments, glassware, laboratory tools, textiles, plastic containers, media for microbiological cultures and food products.

5 What is the difference between a Horizontal and a Vertical Autoclave?

A Horizontal Autoclave has a horizontally aligned chamber, making it easier to load and unload, whereas a Vertical Autoclave has a vertical chamber for smaller items.

6 What kind of maintenance does Horizontal Autoclave require?

Regular maintenance includes proper cleaning, checking of seals and valves, calibrating sensors, and inspecting for wear to ensure efficient and safe functioning.

7 Can Horizontal Autoclave be used in veterinary practices?

It can be used in veterinary practices.

8 Can Horizontal Autoclave be used for research involving pathogens?

It is critical for inactivating dangerous pathogens before disposal or reuse.

9 What is a sterilization hold time in Horizontal Autoclave?

It is the period during which the load is maintained at the sterilization temperature to ensure effective microbial kill.

10 Can Horizontal Autoclave be used to sterilize syringes and glass vials?

It is commonly used to sterilize empty syringes, glass vials and other containers before filling in pharmaceutical environments.