Get Quote
Contact us now to receive a detailed quotation.
LMHA-A204 is a horizontal front-loading autoclave used for Steam Sterilization of laboratory and clinical materials. It operates within 105°C to 134°C using controlled pressure cycles to sterilize instruments, glassware, liquids, and textiles while supporting ISO 17665 and Good Laboratory Practice requirements.
Type: Horizontal front-loading autoclave
Function: Steam sterilization under pressure
Temperature: 105°C to 134°C
Load types: Solid, liquid, wrapped, porous
Suitable for: Laboratories, hospitals, pharma units
Capacity: Medium-to-large batch processing
It is used to sterilize laboratory and clinical materials using high-temperature steam under pressure.
Stainless steel instruments
Borosilicate glassware
Culture media and reagents
Wrapped surgical trays
Cleanroom garments
Biohazard waste
Pharmaceutical laboratories
Biotechnology research centers
Hospital sterile processing departments
Academic institutions
Food testing laboratories
Load materials into chamber
Secure door with interlocks
Remove air (gravity/vacuum)
Introduce saturated steam
Maintain exposure temperature and pressure
Release pressure in controlled manner
Dry and unload
Microprocessor-controlled operation
Adjustable sterilization cycles
Real-time temperature and pressure display
Front-loading chamber design
Integrated safety interlocks
Automatic steam and exhaust regulation
✔ Instruments
✔ Liquid media
✔ Glassware
✔ Textiles
✔ Laboratory waste
Choose this model if:
Medium-to-large batch sterilization is required
Multiple material types are processed
Documentation is needed for audits
Your lab follows Good Laboratory Practice
Very small laboratories
Low-volume sterilization needs
Heat-sensitive material processing
Horizontal autoclave → Medium-to-large batch processing
Vertical autoclave → Space-efficient usage
Benchtop autoclave → Small-scale sterilization
Pass-through autoclave → Cleanroom transfer applications
Yes. It supports programmable cycles for safe liquid sterilization.
Usually between 20 and 60 minutes depending on load type.
Yes. It supports sterile processing workflows.
Yes. It aligns with ISO 17665 and Good Laboratory Practice.
Door interlocks
Pressure monitoring
Emergency shutdown
Sterilizing surgical instruments
Preparing microbiological media
Glassware sterilization
Biohazard waste decontamination
Textile sterilization
Aligned with:
ISO 17665
Good Laboratory Practice
Clinical sterilization protocols
Executive Summary
LMHA-A204 is a horizontal front-loading autoclave designed for steam sterilization of laboratory and clinical materials. It supports structured workflows, programmable cycles, and compliance documentation, making it suitable for facilities handling moderate-to-high sterilization volumes.