Horizontal Autoclave LMHA-B104 provides large volume of 500 litres. Its spoke door structure and safety interlock with self-expanding seal ring ensures secure sealing. It features vacuum drying function for moisture removal and three-level exhaust for controlled steam release. It enables multi-level permission management for restricted access and over one million data record storage. Our Horizontal Autoclave is ideal for laboratories, medical facilities and research centres for high-capacity sterilization.

Catalog Send Mail Whatsapp

Specifications

Volume 500 L
Temperature Range 105°C to 135°C
Pre-Configured Programs 9 (Sterilization) + 3 (Melting and Insulation Programs)
Power Consumption 17 kW
Power Supply 380 V, 50 Hz
Internal Dimension Ø700×1450 mm
Housing Dimension 1000×1915×1803 mm
Package Dimension 2000×1026×2000 mm
Net Weight 670 kg
Gross Weight 720 kg

Pricing

Product Price Unit Action
Horizontal Autoclave LMHA-B104 $ 15250 Each of 1

Features

Bright I intelligent operating system

7-inch touch screen 

6-Level Cold Air Emission

Reservation Function

Water level detection system

Steam Generator and Water Pump

Optional Accessories

Model No

Accessory

LMHA-B104-S1

Stainless steel housing

Applications

Horizontal Autoclave LMHA-B104 is ideal for sterilizing instruments, glassware, media, and medical waste in laboratories, hospitals, research organizations, pharmaceutical facilities and industrial settings.

Autoclave with controlled steam release
Autoclave with controlled steam release

Similar Products

Horizontal Autoclave LMHA-B105

  • Volume: 500 L
  • Temperature Range: 105°C to 135°C
  • Pre-Configured Programs: 9 (Sterilization) + 3 (Melting and Insulation Programs)
  • Power Consumption: 19.1 kW
  • Power Supply: 380 V, 50 Hz

$ 16875 / Each of 1

Horizontal Autoclave LMHA-A401

  • Capacity: 200 L
  • Temperature Range: 134 °C
  • Pressure: 0.22 MPa
  • Time Range: 0 to 60 min
  • Drying Time: 0 to 60 min

$ 8950 / Each of 1

Horizontal Autoclave LMHA-A100

  • Capacity: 120 L
  • Temperature Range: 50 °C to 134 °C
  • Pressure: 0.217 Mpa
  • Time Range: 0 to 99 hr
  • Power: 7.5 kW

$ 6612.5 / Pack of 1

Horizontal Autoclave LMHA-A301
  • Capacity: 200 L
  • Temperature Range: 134 °C
  • Pressure: 0.22 MPa
  • Time Range: 0 to 90 min
  • Drying Time: 0 to 90 min

$ 7687.5 / Each of 1

Horizontal Autoclave LMHA-A502
  • Capacity: 280 L
  • Temperature Range: 134 °C
  • Pressure: 0.22 MPa
  • Time Range: 0 - 99 min
  • Drying Time: 0 - 99 min

$ 13562.5 / Each of 1

Horizontal Autoclave LMHA-A103

  • Chamber Volume: 100 L
  • Temperature Range: 115°C to 134 °C
  • Working Temperature: 134 ℃
  • pressure control range: 0.07-0.22Mpa
  • Working Pressure: 0.22Mpa

$ 5062.5 / Each of 1

Horizontal Autoclave LMHA-A200

  • Capacity: 150 L
  • Temperature Range: 134 °C
  • Pressure: 0.22 MPa
  • Time Range: 0 to 60 min
  • Drying Time: 0 to 60 min

$ 5325 / Pack of 1

Horizontal Autoclave LMHA-A701

  • Capacity: 800 L
  • Door type: Automatic vertical sliding door
  • Vessel design life: Internal Tank: S30408 Stainless Steel, Jacket: Q245R, Life: 10 years, Sterilization cycles: 20000Inner Liner: 316 L Stainless Steel, Jacket: S30408, Life:15 years, Sterilization cycles: 30000
  • Steam consumption: 45 Kg/C
  • Design Pressure of Inner Chamber: -0.1 to 0.3 MPa

$ 26237.5 / Pack of 1

Horizontal Autoclave LMHA-A204
  • Capacity: 500 L
  • Temperature Range: 134 °C
  • Pressure: 0.22 MPa
  • Time Range: 0 to 60 min
  • Drying Time: 0 to 60 min

$ 8612.5 / Pack of 1

Horizontal Autoclave LMHA-A402
  • Capacity: 280 L
  • Temperature Range: 134 °C
  • Pressure: 0.22 MPa
  • Time Range: 0 to 60 min
  • Drying Time: 0 to 60 min

$ 13225 / Each of 1

Horizontal Autoclave LMHA-A400

  • Capacity: 150 L
  • Temperature Range: 134 °C
  • Pressure: 0.22 MPa
  • Time Range: 0 to 60 min
  • Drying Time: 0 to 60 min

$ 7800 / Each of 1

Horizontal Autoclave LMHA-A203

  • Capacity: 400 L
  • Temperature Range: 134 °C
  • Pressure: 0.22 MPa
  • Time Range: 0 to 60 min
  • Drying Time: 0 to 60 min

$ 4275 / Each of 1

Horizontal Autoclave LMHA-A102

  • Capacity: 300 L
  • Temperature Range: 50 °C to 134 °C
  • Pressure: 0.217 Mpa
  • Time Range: 0 to 99 hr
  • Power: 7.5 kW

$ 11087.5 / Pack of 1

Horizontal Autoclave LMHA-A101
  • Capacity: 200 L
  • Temperature Range: 50 °C to 134 °C
  • Pressure: 0.217 Mpa
  • Time Range: 0 to 99 hr
  • Power: 7.5 kW

$ 8912.5 / Pack of 1

Horizontal Autoclave LMHA-A302
  • Capacity: 280 L
  • Temperature Range: 134 °C
  • Pressure: 0.22 MPa
  • Time Range: 0 to 90 min
  • Drying Time: 0 to 90 min

$ 9025 / Each of 1

Frequently Asked Questions

1 What is a Horizontal Autoclave LMHA-B104?

A Horizontal Autoclave LMHAB104 is a large capacity, front-loading steam sterilizer designed for laboratory, medical, research, and pharmaceutical use.

2 How does Horizontal Autoclave LMHA-B104 work?

Horizontal Autoclave LMHA-B104 works on the principle of moist heat sterilization.

3 Can Horizontal Autoclave LMHA-B104 sterilize biohazardous waste safely?

Horizontal Autoclave LMHA-B104 is designed to safely sterilize biohazardous and medical waste, ensuring that all pathogens are neutralized before disposal.

4 What is the role of Horizontal Autoclave LMHA-B104 in pharmaceutical production?

In pharmaceutical production, the Horizontal Autoclave LMHA-B104 sterilizes equipment, media to ensure contamination-free manufacturing environments and product safety.

5 How is Horizontal Autoclave LMHA-B104 used in forensic laboratories?

Horizontal Autoclave LMHA-B104 sterilizes forensic evidence tools and materials, preventing contamination and ensuring chain-of-custody integrity in forensic investigations.

6 What role does Horizontal Autoclave LMHA-B104 play in agricultural research labs?

Horizontal Autoclave LMHA-B104 sterilizes soil samples, plant tissue cultures, and laboratory tools, ensuring contamination-free environments for accurate agricultural research.

7 How is Horizontal Autoclave LMHA-B104 utilized in clinical settings?

Horizontal Autoclave LMHA-B104 sterilizes surgical instruments, diagnostic tools, and clinical waste, ensuring patient safety and infection control in hospitals and clinics.

8 How does Horizontal Autoclave LMHA-B104 benefit nanobiotechnology applications?

Horizontal Autoclave LMHA-B104 is used in nanobiotechnology laboratories to sterilize biological reagents, culture media, and tools ensuring aseptic conditions.

9 Is Horizontal Autoclave LMHA-B104 suitable for Biosafety Level laboratories?

Horizontal Autoclave LMHA-B104 sterilizes non-hazardous lab tools and cultures in Biosafety level laboratories.

10 How is Horizontal Autoclave LMHA-B104 used in aerospace material testing laboratories?

Horizontal Autoclave LMHA-B104 is used to sterilize test apparatus and tools to prevent contamination during aerospace material analysis and component validation.

11 What is a Horizontal Autoclave?

A Horizontal Autoclave is an apparatus designed to use high-pressure steam in a horizontally oriented chamber to sterilize equipment and materials.

12 How does a Horizontal Autoclave work?

It works by using high-pressure steam to heat and sterilize materials inside a sealed chamber.

13 Can Horizontal Autoclave be used for both solid and liquid sterilization?

It is versatile and can sterilize both solid items and liquids.

14 What materials can be sterilized in Horizontal Autoclave?

It can sterilize a variety of materials such as surgical instruments, glassware, laboratory tools, textiles, plastic containers, media for microbiological cultures and food products.

15 What is the difference between a Horizontal and a Vertical Autoclave?

A Horizontal Autoclave has a horizontally aligned chamber, making it easier to load and unload, whereas a Vertical Autoclave has a vertical chamber for smaller items.

16 What kind of maintenance does Horizontal Autoclave require?

Regular maintenance includes proper cleaning, checking of seals and valves, calibrating sensors, and inspecting for wear to ensure efficient and safe functioning.

17 Can Horizontal Autoclave be used in veterinary practices?

It can be used in veterinary practices.

18 Can Horizontal Autoclave be used for research involving pathogens?

It is critical for inactivating dangerous pathogens before disposal or reuse.

19 What is a sterilization hold time in Horizontal Autoclave?

It is the period during which the load is maintained at the sterilization temperature to ensure effective microbial kill.

20 Can Horizontal Autoclave be used to sterilize syringes and glass vials?

It is commonly used to sterilize empty syringes, glass vials and other containers before filling in pharmaceutical environments.