LMHA-A402 is a horizontal front-loading steam autoclave used for sterilizing laboratory and clinical materials using controlled temperature (105°C–134°C) and pressure cycles. It is suitable for instruments, glassware, liquids, textiles, and biohazard waste while supporting ISO 17665 and GLP practices.
Type: Horizontal steam autoclave
Loading: Front-loading
Temperature Range: 105°C – 134°C
Applications: Instruments, liquids, textiles, glassware
Industries: Pharmaceutical, healthcare, research laboratories
Compliance: ISO 17665, GLP
LMHA-A402 is used for sterilizing:
Stainless steel instruments
Laboratory glassware
Culture media and reagents
Wrapped surgical trays
Cleanroom garments
Biohazard waste
It supports contamination control and sterile processing workflows in regulated environments.
Materials are loaded into horizontal chamber
Door is sealed with safety interlocks
Air is removed (gravity or vacuum method)
Steam reaches programmed temperature
Load is held for defined exposure time
Controlled pressure release occurs
Drying phase completes the cycle
Microprocessor-controlled cycles
Adjustable temperature and sterilization time
Horizontal stainless steel chamber
Real-time monitoring of pressure and temperature
Automatic steam regulation
Door safety interlock mechanism
Yes. It supports:
Liquid sterilization using controlled heating cycles
Wrapped and porous load sterilization through effective steam penetration
Yes. It is used in:
Hospital sterile processing departments (CSPD)
Pharmaceutical laboratories
Biotechnology research centers
Academic and diagnostic laboratories
Choose this model if:
High-capacity sterilization is required
Mixed load types (liquids + solids) are processed
Documented sterilization cycles are needed
Wrapped or porous materials are handled
Front-loading improves workflow organization
Small-volume sterilization → consider benchtop models
Limited space → vertical autoclave may be preferable
Heat-sensitive materials → use non-steam sterilization methods
Horizontal autoclave: Better for large batches and structured loading
Vertical autoclave: Suitable for compact spaces and smaller loads
Temperature Range: 105°C – 134°C
Pressure Range: 0.1 – 0.25 MPa
Chamber: Horizontal stainless steel
Control: Digital microprocessor
Power Supply: 220 V AC, 50/60 Hz
Loading Type: Front-loading
It is used for steam sterilization of instruments, glassware, liquids, textiles, and laboratory waste in clinical and research environments.
Yes, programmable cycles allow controlled sterilization of liquid media and reagents.
It operates between 105°C and 134°C depending on the selected cycle.
Yes, it supports hospital sterile processing workflows including CSPD applications.
Temperature, pressure, and cycle time are displayed in real time through a digital control interface.
Yes, it aligns with ISO 17665 and Good Laboratory Practice documentation standards.
Sterilization of surgical instruments
Laboratory media preparation
Glassware sterilization
Biohazard waste decontamination
Textile sterilization
ISO 17665 – Steam sterilization
Good Laboratory Practice (GLP)
Clinical laboratory sterilization protocols