Capacity

Temperature Range

Bath Temperature Range

Pressure

Temperature Measurement Accuracy

Single Layer Glass Reactor

Labmate Single Layer Glass Reactor is designed with wide capacity range from 500 ml to 200 L. They feature durable glass material to ensure low expansion rates and to protect from high-temperature and corrosion. Their fluorine rubber sealing systems maintain high vacuum. These provide constant speed functionality, enhancing safety, stability, and longevity. Our Glass Reactor ensures pharmaceutical synthesis, pesticide formulation, and petroleum refining.

Single Layer Glass Reactor LMSLR-A100

  • Capacity: 0.5 L
  • Temperature Range: -80 to 200°C
  • Pressure: -0.098 MPa
  • Dropping Funnel Volume: 0.25 L
  • Receiving Flask Volume: 0.25 L

$ 3650 / Each of 1

Single Layer Glass Reactor LMSLR-A101

  • Capacity: 1 L
  • Temperature Range: -80 to 200°C
  • Pressure: -0.098 MPa
  • Dropping Funnel Volume: 0.25 L
  • Receiving Flask Volume: 0.25 L

$ 3750 / Each of 1

Single Layer Glass Reactor LMSLR-A103
  • Capacity: 3 L
  • Temperature Range: -80 to 200°C
  • Pressure: -0.098 MPa
  • Dropping Funnel Volume: 0.25 L
  • Receiving Flask Volume: 0.25 L

$ 3850 / Each of 1

Single Layer Glass Reactor LMSLR-A102
  • Capacity: 2 L
  • Temperature Range: -80 to 200°C
  • Pressure: -0.098 MPa
  • Dropping Funnel Volume: 0.25 L
  • Receiving Flask Volume: 0.25 L

$ 3812.5 / Each of 1

Single Layer Glass Reactor LMSLR-A104

  • Capacity: 5 L
  • Temperature Range: -80 to 200°C
  • Pressure: -0.098 MPa
  • Dropping Funnel Volume: 0.5 L
  • Receiving Flask Volume: 0.25 L

$ 4150 / Each of 1

Single Layer Glass Reactor LMSLR-A105

  • Capacity: 10 L
  • Temperature Range: -80 to 200°C
  • Pressure: -0.098 MPa
  • Dropping Funnel Volume: 1 L
  • Receiving Flask Volume: 0.5 L

$ 5375 / Each of 1

Single Layer Glass Reactor LMSLR-A106
  • Capacity: 20 L
  • Temperature Range: -80 to 200°C
  • Pressure: -0.098 MPa
  • Dropping Funnel Volume: 1 L
  • Receiving Flask Volume: 0.5 L

$ 5937.5 / Each of 1

Single Layer Glass Reactor LMSLR-A107
  • Capacity: 30 L
  • Temperature Range: -80 to 200°C
  • Pressure: -0.098 MPa
  • Dropping Funnel Volume: 1 L
  • Receiving Flask Volume: 0.5 L

$ 6312.5 / Each of 1

Single Layer Glass Reactor LMSLR-A108

  • Capacity: 50 L
  • Temperature Range: -80 to 200°C
  • Pressure: -0.098 MPa
  • Dropping Funnel Volume: 1 L
  • Receiving Flask Volume: 0.5 L

$ 6687.5 / Each of 1

Single Layer Glass Reactor LMSLR-A109

  • Capacity: 100 L
  • Temperature Range: -80 to 200°C
  • Pressure: -0.098 MPa
  • Dropping Funnel Volume: 2 L
  • Receiving Flask Volume: 0.5 L

$ 8750 / Each of 1

Single Layer Glass Reactor LMSLR-A110
  • Capacity: 200 L
  • Temperature Range: -80 to 200°C
  • Pressure: -0.098 MPa
  • Dropping Funnel Volume: 2 L
  • Receiving Flask Volume: 0.5 L

$ 17275 / Each of 1

Single Layer Glass Reactor LMSLR-B100
  • Capacity: 1 L
  • Temperature Range: -80 to 250°C
  • Bath Temperature Range: RT to 180°C
  • Temperature Measurement Accuracy: ±1°C
  • Vacuum Degree: 0.098 MPa

$ 2175 / Each of 1

Single Layer Glass Reactor LMSLR-B101

  • Capacity: 2 L
  • Temperature Range: -80 to 250°C
  • Bath Temperature Range: RT to 180°C
  • Temperature Measurement Accuracy: ±1°C
  • Vacuum Degree: 0.098 MPa

$ 2262.5 / Each of 1

Single Layer Glass Reactor LMSLR-B102

  • Capacity: 3 L
  • Temperature Range: -80 to 250°C
  • Bath Temperature Range: RT to 180°C
  • Temperature Measurement Accuracy: ±1°C
  • Vacuum Degree: 0.098 MPa

$ 2400 / Each of 1

Single Layer Glass Reactor LMSLR-B103
  • Capacity: 5 L
  • Temperature Range: -80 to 250°C
  • Bath Temperature Range: RT to 180°C
  • Temperature Measurement Accuracy: ±1°C
  • Vacuum Degree: 0.098 MPa

$ 2500 / Each of 1

Single Layer Glass Reactor LMSLR-B104
  • Capacity: 10 L
  • Temperature Range: -80 to 250°C
  • Temperature Measurement Accuracy: ±1°C
  • Vacuum Degree: 0.098 MPa
  • Dropping Funnel Volume: 1 L

$ 2825 / Each of 1

Single Layer Glass Reactor LMSLR-B105

  • Capacity: 20 L
  • Temperature Range: -80 to 250°C
  • Temperature Measurement Accuracy: ±1°C
  • Vacuum Degree: 0.098 MPa
  • Dropping Funnel Volume: 1 L

$ 3187.5 / Each of 1

Single Layer Glass Reactor LMSLR-B106

  • Capacity: 30 L
  • Temperature Range: -80 to 250°C
  • Temperature Measurement Accuracy: ±1°C
  • Vacuum Degree: 0.098 MPa
  • Dropping Funnel Volume: 2 L

$ 3487.5 / Each of 1

Single Layer Glass Reactor LMSLR-B107
  • Capacity: 50 L
  • Temperature Range: -80 to 250°C
  • Temperature Measurement Accuracy: ±1°C
  • Vacuum Degree: 0.098 MPa
  • Dropping Funnel Volume: 2 L

$ 3562.5 / Each of 1

Single Layer Glass Reactor LMSLR-B108
  • Capacity: 100 L
  • Temperature Range: -80 to 250°C
  • Temperature Measurement Accuracy: ±1°C
  • Vacuum Degree: 0.098 MPa
  • Dropping Funnel Volume: 2 L

$ 4481.25 / Each of 1

Single Layer Glass Reactor LMSLR-B109

  • Capacity: 100 L
  • Temperature Range: -80 to 250°C
  • Temperature Measurement Accuracy: ±1°C
  • Vacuum Degree: 0.098 MPa
  • Dropping Funnel Volume: 5 L

$ 3675 / Each of 1

Single Layer Glass Reactor LMSLR-B110

  • Capacity: 200 L
  • Temperature Range: -80 to 250°C
  • Temperature Measurement Accuracy: ±1°C
  • Vacuum Degree: 0.098 MPa
  • Receiving Bottle Volume: 10 L

$ 6887.5 / Each of 1

Frequently Asked Questions

1 What is a Single Layer Glass Reactor?

A Single Layer Glass Reactor is an apparatus designed for chemical reactions with a single-layer wall for clear visibility and chemical resistance.

2 How is temperature controlled in Single Layer Glass Reactor?

Temperature control is typically achieved through external jackets or immersion in temperature-controlled baths, ensuring precise reaction conditions.

3 Can Single Layer Glass Reactor be used for pharmaceutical synthesis?

It is widely used in pharmaceutical synthesis for precise control and monitoring of chemical reactions.

4 Is Single Layer Glass Reactor suitable for polymerization processes?

It is ideal for polymerization due to its chemical resistance and ability to maintain controlled reaction environments.

5 Can Single Layer Glass Reactor be used for crystallization applications?

It is commonly employed in crystallization to observe crystal formation clearly and maintain proper reaction conditions.

6 Is Single Layer Glass Reactor used in research and development labs?

It is a standard tool in R&D labs for experimental reactions and process optimization.

7 Is Single Layer Glass Reactor used for food and flavor industry applications?

It is used in the food and flavor industry for controlled reaction processes and product development.

8 Can Single Layer Glass Reactor be used for catalyst testing?

It is commonly used for catalyst testing due to its transparent design, allowing observation of catalytic reactions.

9 Can Single Layer Glass Reactor be used in environmental testing applications?

It is often used in environmental labs for testing reactions related to pollution control and remediation.

10 Is Single Layer Glass Reactor used for quality control testing in manufacturing?

It is used in quality control to simulate and monitor chemical processes for consistency.