Single Layer Glass Reactor LMSLR-B109 features cylindrical vessel with 100-liter capacity. Its stirring paddle ensures thorough material mixing, promoting uniform distribution and improved reaction. Equipped with controller unit, it regulates rotation speed and temperature settings with an intuitive interface. Incorporates constant-pressure funnel for stable liquid feeding without causing fluctuations. Our Reactor is ideal for solvent recovery, distillation, and concentration.

Catalog Send Mail Whatsapp

Specifications

Capacity 100 L
Temperature Range -80 to 250°C
Temperature Measurement Accuracy ±1°C
Vacuum Degree 0.098 MPa
Dropping Funnel Volume 5 L
Rotation Speed Range 0 to 450 rpm
Stirring Motor Power 200W1/3
Heating Power 15kW
Power Supply 220V/50Hz (Stirrer), 330V/50Hz (Heating bath)
Dimensions (W×D×H) 900×770×2250 mm
Weight 110 Kg

Pricing

Product Price Unit Action
Single Layer Glass Reactor LMSLR-B109 $ 3675 Each of 1

Features

Efficient thermal transfer

High-torque motor

Low noise operation

Chemical-resistant surfaces

External vacuum connectivity

Mobile caster base

Dual-seal protection

Applications

Single Layer Glass Reactor LMSLR-B109 is widely employed for vacuum evaporation, crystallization, chemical synthesis, solvent recovery, pharmaceutical formulation, concentration, and distillation.

Similar Products

Single Layer Glass Reactor LMSLR-B106

  • Capacity: 30 L
  • Temperature Range: -80 to 250°C
  • Temperature Measurement Accuracy: ±1°C
  • Vacuum Degree: 0.098 MPa
  • Dropping Funnel Volume: 2 L

$ 3487.5 / Each of 1

Single Layer Glass Reactor LMSLR-A108

  • Capacity: 50 L
  • Temperature Range: -80 to 200°C
  • Pressure: -0.098 MPa
  • Dropping Funnel Volume: 1 L
  • Receiving Flask Volume: 0.5 L

$ 6687.5 / Each of 1

Single Layer Glass Reactor LMSLR-B104

  • Capacity: 10 L
  • Temperature Range: -80 to 250°C
  • Temperature Measurement Accuracy: ±1°C
  • Vacuum Degree: 0.098 MPa
  • Dropping Funnel Volume: 1 L

$ 2825 / Each of 1

Single Layer Glass Reactor LMSLR-B101
  • Capacity: 2 L
  • Temperature Range: -80 to 250°C
  • Bath Temperature Range: RT to 180°C
  • Temperature Measurement Accuracy: ±1°C
  • Vacuum Degree: 0.098 MPa

$ 2262.5 / Each of 1

Single Layer Glass Reactor LMSLR-A100
  • Capacity: 0.5 L
  • Temperature Range: -80 to 200°C
  • Pressure: -0.098 MPa
  • Dropping Funnel Volume: 0.25 L
  • Receiving Flask Volume: 0.25 L

$ 3650 / Each of 1

Single Layer Glass Reactor LMSLR-A102

  • Capacity: 2 L
  • Temperature Range: -80 to 200°C
  • Pressure: -0.098 MPa
  • Dropping Funnel Volume: 0.25 L
  • Receiving Flask Volume: 0.25 L

$ 3812.5 / Each of 1

Single Layer Glass Reactor LMSLR-A110

  • Capacity: 200 L
  • Temperature Range: -80 to 200°C
  • Pressure: -0.098 MPa
  • Dropping Funnel Volume: 2 L
  • Receiving Flask Volume: 0.5 L

$ 17275 / Each of 1

Single Layer Glass Reactor LMSLR-A109

  • Capacity: 100 L
  • Temperature Range: -80 to 200°C
  • Pressure: -0.098 MPa
  • Dropping Funnel Volume: 2 L
  • Receiving Flask Volume: 0.5 L

$ 8750 / Each of 1

Single Layer Glass Reactor LMSLR-A104
  • Capacity: 5 L
  • Temperature Range: -80 to 200°C
  • Pressure: -0.098 MPa
  • Dropping Funnel Volume: 0.5 L
  • Receiving Flask Volume: 0.25 L

$ 4150 / Each of 1

Single Layer Glass Reactor LMSLR-A107
  • Capacity: 30 L
  • Temperature Range: -80 to 200°C
  • Pressure: -0.098 MPa
  • Dropping Funnel Volume: 1 L
  • Receiving Flask Volume: 0.5 L

$ 6312.5 / Each of 1

Single Layer Glass Reactor LMSLR-B103

  • Capacity: 5 L
  • Temperature Range: -80 to 250°C
  • Bath Temperature Range: RT to 180°C
  • Temperature Measurement Accuracy: ±1°C
  • Vacuum Degree: 0.098 MPa

$ 2500 / Each of 1

Single Layer Glass Reactor LMSLR-A101

  • Capacity: 1 L
  • Temperature Range: -80 to 200°C
  • Pressure: -0.098 MPa
  • Dropping Funnel Volume: 0.25 L
  • Receiving Flask Volume: 0.25 L

$ 3750 / Each of 1

Single Layer Glass Reactor LMSLR-B105

  • Capacity: 20 L
  • Temperature Range: -80 to 250°C
  • Temperature Measurement Accuracy: ±1°C
  • Vacuum Degree: 0.098 MPa
  • Dropping Funnel Volume: 1 L

$ 3187.5 / Each of 1

Single Layer Glass Reactor LMSLR-B107
  • Capacity: 50 L
  • Temperature Range: -80 to 250°C
  • Temperature Measurement Accuracy: ±1°C
  • Vacuum Degree: 0.098 MPa
  • Dropping Funnel Volume: 2 L

$ 3562.5 / Each of 1

Single Layer Glass Reactor LMSLR-B100
  • Capacity: 1 L
  • Temperature Range: -80 to 250°C
  • Bath Temperature Range: RT to 180°C
  • Temperature Measurement Accuracy: ±1°C
  • Vacuum Degree: 0.098 MPa

$ 2175 / Each of 1

Frequently Asked Questions

1 What is a Single Layer Glass Reactor?

A Single Layer Glass Reactor is an apparatus designed for chemical reactions with a single-layer wall for clear visibility and chemical resistance.

2 How is temperature controlled in Single Layer Glass Reactor?

Temperature control is typically achieved through external jackets or immersion in temperature-controlled baths, ensuring precise reaction conditions.

3 Can Single Layer Glass Reactor be used for pharmaceutical synthesis?

It is widely used in pharmaceutical synthesis for precise control and monitoring of chemical reactions.

4 Is Single Layer Glass Reactor suitable for polymerization processes?

It is ideal for polymerization due to its chemical resistance and ability to maintain controlled reaction environments.

5 Can Single Layer Glass Reactor be used for crystallization applications?

It is commonly employed in crystallization to observe crystal formation clearly and maintain proper reaction conditions.

6 Is Single Layer Glass Reactor used in research and development labs?

It is a standard tool in R&D labs for experimental reactions and process optimization.

7 Is Single Layer Glass Reactor used for food and flavor industry applications?

It is used in the food and flavor industry for controlled reaction processes and product development.

8 Can Single Layer Glass Reactor be used for catalyst testing?

It is commonly used for catalyst testing due to its transparent design, allowing observation of catalytic reactions.

9 Can Single Layer Glass Reactor be used in environmental testing applications?

It is often used in environmental labs for testing reactions related to pollution control and remediation.

10 Is Single Layer Glass Reactor used for quality control testing in manufacturing?

It is used in quality control to simulate and monitor chemical processes for consistency.