Get Quote

Contact us now to receive a detailed quotation.

Need quick help? Chat with us on WhatsApp:

WhatsApp QR Code

OR

TOC Analyzer LMTOC-B104

TOC Analyzer LMTOC-B104 offers automatic sample dilution and 0 to 1000 mg/L measurement range. It features 680°C catalytic oxidation with platinum catalyst for reliable measurement. Equipped with three-stage dehydration system, it enhances moisture removal and improves final gas drying. Incorporates standard curve management that simplifies calibration and enhances convenience. Our Analyzer is ideal for TOC measurement in seawater, pharma, industrial, and environmental samples. 

Catalog Send Mail Whatsapp

Specifications

Measurement Range 0 to 1000 mg/L, can extend to 0 to 100,000mg/L
Measurement Method High Temperature Catalytic Combustion
Detector NDIR
Detection Limit IC: 20μg/L
Analysis Parameter TC, TIC, TOC, NPOC
Control Mode PC software Control
Gas Requirement Oxygen, purity greater than equal to 99.995%
Sample Type Solid Sample
Dilution Method Automatic
Measuring Time IC: 3min
Maximum Permissible Error IC: ± 4%
Repeatability Less than or equal to 3%
Injection Volume IC: 100 to 2000μL
Power Consumption 700W
Power Supply AC110/220V, 50/60Hz
Dimension 450×500×480 mm
Packing Dimension 780×710×610 mm
Net Weight 46 Kg
Gross Weight 66 Kg

Pricing

Product Price Unit Action
TOC Analyzer LMTOC-B104 $ 26250 Each of 1

Features

Multi-functional software

PID temperature control

Consumables alert

Modular design

High sensitivity

Simplified operation

Optional Accessories

Model No.

Accessory Name

LMTOC-B104-A1

Autosampler (Liquid)

LMTOC-B104-A2

Autosampler (Solid)

Applications

TOC Analyzer LMTOC-B104 is ideal for measuring TOC in seawater, pharmaceutical-grade water, industrial wastewater, and environmental samples to ensure compliance, process control, and high-purity water quality assurance.

Product Accessories

LMTOC-B104-A1

No. of sample positions- 19, Volume of Sample Bottle- 60mL

LMTOC-B104-A2

Measurement Range- 0.1 to 30.0mg , Measurement Time- 5 to 8min

Similar Products

TOC Analyzer LMTOC-B103

  • Measurement Range: 0 to 1000 mg/L, can extend to 0 to 100,000mg/L
  • Measurement Method: High Temperature Catalytic Combustion
  • Detector: NDIR
  • Detection Limit: TC: 50μg/L
  • Analysis Parameter: TC, TIC, TOC, NPOC

$ 21000 / Each of 1

TOC Analyzer LMTOC-A100

  • Detector: NDIR
  • Detection Limit: 5µg/l
  • Parameters: TC, TIC, TOC, NPOC
  • Measurement Range: 0 to 10000 mg/l
  • Digestion Mode: Wet chemical oxidation by UV

$ 26625 / Pack of 1

TOC Analyzer LMTOC-B100

  • Measurement Range: 1 to 1500 ppb
  • Detection Limit: 1ppb
  • Sample Flow Speed: 2mL/min
  • Analysis Time: 3 min
  • Response Time: 10 min

$ 14000 / Each of 1

TOC Analyzer LMTOC-B102
  • Measurement Range: 0 to 10000 mg/L (ppm)
  • Measurement Method: Wet Chemical Oxidation by UV
  • Detector: NDIR
  • Detection Limit: 5μg/L (ppb)
  • Analysis Parameter: TC, TIC, TOC, NPOC

$ 21000 / Each of 1

TOC Analyzer LMTOC-A101
  • Analysis Method: Combustion catalytic oxidation
  • Detection Limit: 0.001mg/L (0.001ppm)
  • Analysis Time: 4min
  • Flow rate: 0.5 mL/min
  • Decomposition Principle: UV ray decomposition

$ 18912.5 / Pack of 1

TOC Analyzer LMTOC-B101

  • Measurement Range: 1 to 1500 ppb
  • Detection Limit: 1ppb
  • Sample Flow Speed: 2mL/min
  • Mode Of Operation: Online
  • Analysis Time: 3 min

$ 14875 / Each of 1

Frequently Asked Questions

1 What is a TOC Analyzer?

A TOC Analyzer is an apparatus designed to analyze the organic carbon content in water or other liquid samples.

2 How does a TOC Analyzer work?

It operate by oxidizing organic carbon in sample to carbon dioxide, which is then measured to determine the total organic carbon content.

3 What types of samples can be analyzed using TOC Analyzer?

It is used to analyze a wide variety of samples such as drinking water, wastewater pharmaceutical water, environmental water, food and beverage samples.

4 How is calibration done in case of TOC Analyzer?

Calibration is done using standard solutions of known organic carbon content in order to ensure that the analyzer is providing accurate readings.

5 What kind of maintenance does TOC Analyzer require?

Regular maintenance includes proper cleaning of the apparatus, replacing consumables like filters, reagents or electrodes and performing regular calibration.

6 Can TOC Analyzer test both tap water and river water?

It can test both tap water and river water to measure the amount of organic carbon in each sample.

7 What is the difference between a TOC Analyzer and a UV-Vis Spectrophotometer?

A TOC Analyzer measures organic carbon content directly whereas a UV-Vis Spectrophotometer analyzes light absorption to identify the concentration of various compounds.

8 Can TOC Analyzer be used for both raw and treated water?

It is used to measure organic carbon in both raw and treated water thereby helping in assessing the effectiveness of water treatment process.

9 Is TOC Analyzer affected by temperature?

Temperature fluctuations affect the accuracy of TOC Analyzer results.

10 What is the difference between a TOC Analyzer and a COD Analyzer?

A TOC Analyzer measures the total organic carbon, whereas a COD Analyzer measures the oxygen demand required to oxidize both organic and inorganic contaminants in water.