TOC Analyzer LMTOC-B103

TOC Analyzer LMTOC-B103 has measurement range 0 to 1000 mg/L with an NDIR detector. It features modular design for easy handling, faster servicing, and reduced maintenance time. Equipped with consumables alert system, it reminds operators to replace items before depletion. Incorporates multi-functional PC software for streamlined data tracking, control, and report generation. Our Analyzer is ideal for TOC analysis in seawater, pharma, wastewater, and environmental monitoring.

Catalog Send Mail Whatsapp

Specifications

Measurement Range 0 to 1000 mg/L, can extend to 0 to 100,000mg/L
Measurement Method High Temperature Catalytic Combustion
Detector NDIR
Detection Limit TC: 50μg/L
Analysis Parameter TC, TIC, TOC, NPOC
Control Mode PC software Control
Gas Requirement Oxygen, purity greater than equal to 99.995%
Sample Type Liquid Sample
Dilution Method Manual
Measuring Time TC: 4min
Maximum Permissible Error TOC: ± 5%
Repeatability Less than or equal to 3%
Injection Volume TC: 100 to 500μL
Power Consumption 700W
Power Supply AC110/220V, 50/60Hz
Dimension 450×500×480 mm
Packing Dimension 780×710×610 mm
Net Weight 46 Kg
Gross Weight 66 Kg

Pricing

Product Price Unit Action
TOC Analyzer LMTOC-B103 $ 21000 Each of 1

Features

Platinum catalyst

High sensitivity

PID temperature control

Three-stage dehydration

Efficient drying

Standard curve management

Optional Accessories

Model No.

Accessory Name

LMTOC-B103-A1

Autosampler (Liquid)

LMTOC-B103-A2

Autosampler (Solid)

Applications

TOC Analyzer LMTOC-B103 measures TOC in seawater, industrial wastewater, pharmaceutical-grade water, and environmental samples to ensure quality control, regulatory compliance, and operational efficiency in demanding testing environments.

Product Accessories

LMTOC-B103-A1

No. of sample positions- 19 , Volume of Sample Bottle- 60mL

LMTOC-B103-A2

Measurement Range- 0.1 to 30.0mg , Measurement Time- 5 to 8min

Similar Products

TOC Analyzer LMTOC-A100

  • Detector: NDIR
  • Detection Limit: 5µg/l
  • Parameters: TC, TIC, TOC, NPOC
  • Measurement Range: 0 to 10000 mg/l
  • Digestion Mode: Wet chemical oxidation by UV

$ 26625 / Pack of 1

TOC Analyzer LMTOC-B104

  • Measurement Range: 0 to 1000 mg/L, can extend to 0 to 100,000mg/L
  • Measurement Method: High Temperature Catalytic Combustion
  • Detector: NDIR
  • Detection Limit: IC: 20μg/L
  • Analysis Parameter: TC, TIC, TOC, NPOC

$ 26250 / Each of 1

TOC Analyzer LMTOC-B101

  • Measurement Range: 1 to 1500 ppb
  • Detection Limit: 1ppb
  • Sample Flow Speed: 2mL/min
  • Mode Of Operation: Online
  • Analysis Time: 3 min

$ 14875 / Each of 1

TOC Analyzer LMTOC-A101
  • Analysis Method: Combustion catalytic oxidation
  • Detection Limit: 0.001mg/L (0.001ppm)
  • Analysis Time: 4min
  • Flow rate: 0.5 mL/min
  • Decomposition Principle: UV ray decomposition

$ 18912.5 / Pack of 1

TOC Analyzer LMTOC-B102
  • Measurement Range: 0 to 10000 mg/L (ppm)
  • Measurement Method: Wet Chemical Oxidation by UV
  • Detector: NDIR
  • Detection Limit: 5μg/L (ppb)
  • Analysis Parameter: TC, TIC, TOC, NPOC

$ 21000 / Each of 1

TOC Analyzer LMTOC-B100

  • Measurement Range: 1 to 1500 ppb
  • Detection Limit: 1ppb
  • Sample Flow Speed: 2mL/min
  • Analysis Time: 3 min
  • Response Time: 10 min

$ 14000 / Each of 1

Frequently Asked Questions

1 What is a TOC Analyzer?

A TOC Analyzer is an apparatus designed to analyze the organic carbon content in water or other liquid samples.

2 How does a TOC Analyzer work?

It operate by oxidizing organic carbon in sample to carbon dioxide, which is then measured to determine the total organic carbon content.

3 What types of samples can be analyzed using TOC Analyzer?

It is used to analyze a wide variety of samples such as drinking water, wastewater pharmaceutical water, environmental water, food and beverage samples.

4 How is calibration done in case of TOC Analyzer?

Calibration is done using standard solutions of known organic carbon content in order to ensure that the analyzer is providing accurate readings.

5 What kind of maintenance does TOC Analyzer require?

Regular maintenance includes proper cleaning of the apparatus, replacing consumables like filters, reagents or electrodes and performing regular calibration.

6 Can TOC Analyzer test both tap water and river water?

It can test both tap water and river water to measure the amount of organic carbon in each sample.

7 What is the difference between a TOC Analyzer and a UV-Vis Spectrophotometer?

A TOC Analyzer measures organic carbon content directly whereas a UV-Vis Spectrophotometer analyzes light absorption to identify the concentration of various compounds.

8 Can TOC Analyzer be used for both raw and treated water?

It is used to measure organic carbon in both raw and treated water thereby helping in assessing the effectiveness of water treatment process.

9 Is TOC Analyzer affected by temperature?

Temperature fluctuations affect the accuracy of TOC Analyzer results.

10 What is the difference between a TOC Analyzer and a COD Analyzer?

A TOC Analyzer measures the total organic carbon, whereas a COD Analyzer measures the oxygen demand required to oxidize both organic and inorganic contaminants in water.