TOC Analyzer LMTOC-B101

TOC Analyzer LMTOC-B101 offers online mode operation with range of 1 to 1500 ppb. It features detachable top-mounted UV oxidation unit for easy cleaning and controlled reactions. Equipped with front touchscreen display, it allows real-time monitoring, data setup, and analysis visualization. Incorporates USB support that enables direct file export for convenient data backup and sharing. Our TOC Analyzer is ideal for measuring total organic carbon levels in high purity water.

Catalog Send Mail Whatsapp

Specifications

Measurement Range 1 to 1500 ppb
Detection Limit 1ppb
Sample Flow Speed 2mL/min
Mode Of Operation Online
Analysis Time 3 min
Response Time 10 min
Maximum Tolerance ±5%
Display Smart 7-inch touchscreen
Storage Capacity 8GB
Repeatability Tolerance Less than or equal to 3%
Power Consumption 100W
Power Supply AC110/220V, 50/60Hz
Dimension 440×220×300 mm
Weight 20 Kg

Pricing

Product Price Unit Action
TOC Analyzer LMTOC-B101 $ 14875 Each of 1

Features

Conductivity detector

One-button sampling

Contamination prevention

Bluetooth printing

Effortless maintenance

Water inlet port

Optional Accessories

Model No.

Accessory Name

LMTOC-B101-A1

Autosampler

Applications

TOC Analyzer LMTOC-B101 is applied for measuring Total Organic Carbon in microelectronics, purified, ultrapure, and injectable-grade water to ensure purity, quality, and regulatory compliance.

Product Accessories

LMTOC-B101-A1

No. of sample positions- 19 , Volume of Sample Bottle- 60mL

Similar Products

TOC Analyzer LMTOC-B103

  • Measurement Range: 0 to 1000 mg/L, can extend to 0 to 100,000mg/L
  • Measurement Method: High Temperature Catalytic Combustion
  • Detector: NDIR
  • Detection Limit: TC: 50μg/L
  • Analysis Parameter: TC, TIC, TOC, NPOC

$ 21000 / Each of 1

TOC Analyzer LMTOC-A100

  • Detector: NDIR
  • Detection Limit: 5µg/l
  • Parameters: TC, TIC, TOC, NPOC
  • Measurement Range: 0 to 10000 mg/l
  • Digestion Mode: Wet chemical oxidation by UV

$ 26625 / Pack of 1

TOC Analyzer LMTOC-B100

  • Measurement Range: 1 to 1500 ppb
  • Detection Limit: 1ppb
  • Sample Flow Speed: 2mL/min
  • Analysis Time: 3 min
  • Response Time: 10 min

$ 14000 / Each of 1

TOC Analyzer LMTOC-A101
  • Analysis Method: Combustion catalytic oxidation
  • Detection Limit: 0.001mg/L (0.001ppm)
  • Analysis Time: 4min
  • Flow rate: 0.5 mL/min
  • Decomposition Principle: UV ray decomposition

$ 18912.5 / Pack of 1

TOC Analyzer LMTOC-B104
  • Measurement Range: 0 to 1000 mg/L, can extend to 0 to 100,000mg/L
  • Measurement Method: High Temperature Catalytic Combustion
  • Detector: NDIR
  • Detection Limit: IC: 20μg/L
  • Analysis Parameter: TC, TIC, TOC, NPOC

$ 26250 / Each of 1

TOC Analyzer LMTOC-B102

  • Measurement Range: 0 to 10000 mg/L (ppm)
  • Measurement Method: Wet Chemical Oxidation by UV
  • Detector: NDIR
  • Detection Limit: 5μg/L (ppb)
  • Analysis Parameter: TC, TIC, TOC, NPOC

$ 21000 / Each of 1

Frequently Asked Questions

1 What is a TOC Analyzer?

A TOC Analyzer is an apparatus designed to analyze the organic carbon content in water or other liquid samples.

2 How does a TOC Analyzer work?

It operate by oxidizing organic carbon in sample to carbon dioxide, which is then measured to determine the total organic carbon content.

3 What types of samples can be analyzed using TOC Analyzer?

It is used to analyze a wide variety of samples such as drinking water, wastewater pharmaceutical water, environmental water, food and beverage samples.

4 How is calibration done in case of TOC Analyzer?

Calibration is done using standard solutions of known organic carbon content in order to ensure that the analyzer is providing accurate readings.

5 What kind of maintenance does TOC Analyzer require?

Regular maintenance includes proper cleaning of the apparatus, replacing consumables like filters, reagents or electrodes and performing regular calibration.

6 Can TOC Analyzer test both tap water and river water?

It can test both tap water and river water to measure the amount of organic carbon in each sample.

7 What is the difference between a TOC Analyzer and a UV-Vis Spectrophotometer?

A TOC Analyzer measures organic carbon content directly whereas a UV-Vis Spectrophotometer analyzes light absorption to identify the concentration of various compounds.

8 Can TOC Analyzer be used for both raw and treated water?

It is used to measure organic carbon in both raw and treated water thereby helping in assessing the effectiveness of water treatment process.

9 Is TOC Analyzer affected by temperature?

Temperature fluctuations affect the accuracy of TOC Analyzer results.

10 What is the difference between a TOC Analyzer and a COD Analyzer?

A TOC Analyzer measures the total organic carbon, whereas a COD Analyzer measures the oxygen demand required to oxidize both organic and inorganic contaminants in water.