TOC Analyzer LMTOC-A100

TOC Analyzer LMTOC-A100 is designed with advanced NDIR detection technology to measure the total organic carbon in samples. Improved with high sensitivity carbon detection levels as low as 5µ/l in liquid and gas samples for real time monitoring. Intended with wet chemical oxidation by UV for various sample temperatures. Supplied with automatic leakage prevention system to enhance safety.

Catalog Send Mail Whatsapp

Specifications

Detector NDIR
Detection Limit 5µg/l
Parameters TC, TIC, TOC, NPOC
Measurement Range 0 to 10000 mg/l
Digestion Mode Wet chemical oxidation by UV
Repeatability 0.03
Maximum Salinity 85 g/l
Gas Requirement Nitrogen ≥ 99.995 %
Application Liquid Sample, Gas Sample
Operation Mode PC Control
Power Supply 220 ±10 V,50 / 60 Hz,1 KW
Dimensions 430 × 455 × 440 mm

Pricing

Product Price Unit Action
TOC Analyzer LMTOC-A100 $ 26625 Pack of 1

Features

Detection capabilities include Total Carbon (TC), Total Inorganic Carbon (TIC), Organic Carbon (TOC), and Non-Purgeable Organic Carbon (NPOC)
Utilizes a Non -Dispersive Infrared (NDIR) detector for accurate measurements
Assimilation of carbon is achieved through wet chemical oxidation
Improved flexibility with customizable temperature settings for various samples
Designed with an automatic leakage prevention system for safety

Applications

TOC Analyzer plays a crucial role in various research fields, pharmaceutical and industrial production to ensure water quality, regulatory compliance and facilitating research processes.

Similar Products

TOC Analyzer LMTOC-B100

  • Measurement Range: 1 to 1500 ppb
  • Detection Limit: 1ppb
  • Sample Flow Speed: 2mL/min
  • Analysis Time: 3 min
  • Response Time: 10 min

$ 14000 / Each of 1

TOC Analyzer LMTOC-B102

  • Measurement Range: 0 to 10000 mg/L (ppm)
  • Measurement Method: Wet Chemical Oxidation by UV
  • Detector: NDIR
  • Detection Limit: 5μg/L (ppb)
  • Analysis Parameter: TC, TIC, TOC, NPOC

$ 21000 / Each of 1

TOC Analyzer LMTOC-B103

  • Measurement Range: 0 to 1000 mg/L, can extend to 0 to 100,000mg/L
  • Measurement Method: High Temperature Catalytic Combustion
  • Detector: NDIR
  • Detection Limit: TC: 50μg/L
  • Analysis Parameter: TC, TIC, TOC, NPOC

$ 21000 / Each of 1

TOC Analyzer LMTOC-B101
  • Measurement Range: 1 to 1500 ppb
  • Detection Limit: 1ppb
  • Sample Flow Speed: 2mL/min
  • Mode Of Operation: Online
  • Analysis Time: 3 min

$ 14875 / Each of 1

TOC Analyzer LMTOC-B104
  • Measurement Range: 0 to 1000 mg/L, can extend to 0 to 100,000mg/L
  • Measurement Method: High Temperature Catalytic Combustion
  • Detector: NDIR
  • Detection Limit: IC: 20μg/L
  • Analysis Parameter: TC, TIC, TOC, NPOC

$ 26250 / Each of 1

TOC Analyzer LMTOC-A101

  • Analysis Method: Combustion catalytic oxidation
  • Detection Limit: 0.001mg/L (0.001ppm)
  • Analysis Time: 4min
  • Flow rate: 0.5 mL/min
  • Decomposition Principle: UV ray decomposition

$ 18912.5 / Pack of 1

Frequently Asked Questions

1 What is a TOC Analyzer?

A TOC Analyzer is an apparatus designed to analyze the organic carbon content in water or other liquid samples.

2 How does a TOC Analyzer work?

It operate by oxidizing organic carbon in sample to carbon dioxide, which is then measured to determine the total organic carbon content.

3 What types of samples can be analyzed using TOC Analyzer?

It is used to analyze a wide variety of samples such as drinking water, wastewater pharmaceutical water, environmental water, food and beverage samples.

4 How is calibration done in case of TOC Analyzer?

Calibration is done using standard solutions of known organic carbon content in order to ensure that the analyzer is providing accurate readings.

5 What kind of maintenance does TOC Analyzer require?

Regular maintenance includes proper cleaning of the apparatus, replacing consumables like filters, reagents or electrodes and performing regular calibration.

6 Can TOC Analyzer test both tap water and river water?

It can test both tap water and river water to measure the amount of organic carbon in each sample.

7 What is the difference between a TOC Analyzer and a UV-Vis Spectrophotometer?

A TOC Analyzer measures organic carbon content directly whereas a UV-Vis Spectrophotometer analyzes light absorption to identify the concentration of various compounds.

8 Can TOC Analyzer be used for both raw and treated water?

It is used to measure organic carbon in both raw and treated water thereby helping in assessing the effectiveness of water treatment process.

9 Is TOC Analyzer affected by temperature?

Temperature fluctuations affect the accuracy of TOC Analyzer results.

10 What is the difference between a TOC Analyzer and a COD Analyzer?

A TOC Analyzer measures the total organic carbon, whereas a COD Analyzer measures the oxygen demand required to oxidize both organic and inorganic contaminants in water.