Single Beam UV/Visible Spectrophotometer LMUS-C104

Single Beam UV/Visible Spectrophotometer LMUS-C104 operates across wavelength range of 190 to 1100 nm. Features 1nm spectral bandwidth optimized for consistent measurement output. Equipped with silicon photodiode detector that ensures stable performance during transmission and absorbance evaluations. It provides smooth operation under different scanning speeds for versatile performance. Our Spectrophotometer with deuterium and tungsten lamps offers continuous and stable light across the UV and visible spectrum.

Catalog Send Mail Whatsapp

Specifications

Wavelength 190 nm to 1100 nm
Spectral Bandwidth 1 nm
Optical System Single Beam, Grating 1200 lines/mm
Wavelength Accuracy ±0.1nm at 656.1nm, ±0.3nm at other wavelengths
Wavelength Repeatability Less than or equal to 0.1 nm
Wavelength Setting Auto
Photometric Range 0 to 200%T, –0.3 to 3A, 0 to 9999C
Photometric Accuracy ±0.2%T(0 to 100%T), ±0.002A(0 to 0.5A), ±0.004A(0.5 to 1A)
Photometric Repeatability Less than or equal to 0.15%T (0 to 100%T), 0.001A(0 to 0.5A), 0.002A(0.5 to 1A)
Stray Light Less than or equal to 0.03%T at 220nm, 360nm
Stability ±0.0005A/h at 500nm
Baseline Flatness ±0.001A
Noise 0.0005A at 500nm
Detector Silicon Photodiode
Light Source Deuterium and Tungsten lamp
Work Mode T, A, C, E
Scanning Speed High, Medium, Low (Max. 3000nm/min)
Cuvette Holder 10mm manual 4-cell holder
Output USB drive, USB host, RS232
Display 7-inch Color Screen
Power AC 110 to 220V/50 to 60Hz
Package Dimension 810×660×390 mm
Gross Weight 27 kg

Pricing

Product Price Unit Action
Single Beam UV/Visible Spectrophotometer LMUS-C104 $ 3684 Each of 1

Features

7-inch color screen

Multiple analytical modes

Advanced photometric stability

In-house massive memory

Support USB storage

Manual 4-cell cuvette holder

Large sample chamber

Standard Accessories

Model No.

Accessory

LMUS-C104-G1

10mm Glass cuvette

LMUS-C104-Q1

10mm Quartz cuvette

LMUS-C104-P1

Power cord

LMUS-C104-PC1

PC Software

Applications

Single Beam UV/Visible Spectrophotometer LMUS-C104 is employed in biochemical analysis, material testing, and routine laboratory spectroscopy. It is ideal for wavelength scanning, multi-wavelength analysis, kinetic studies, and quantitative analysis.

Similar Products

Single Beam UV/Visible Spectrophotometer LMUS-A307

  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: 2 nm
  • Wavelength Repeatability: 1 nm

$ 1596 / Pack of 1

Single Beam UV/Visible Spectrophotometer LMUS-C102

  • Wavelength: 190 nm to 1100 nm
  • Spectral Bandwidth: 0.1/0.2/0.5/1/2/4/5 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ±0.3nm
  • Wavelength Repeatability: Less than or equal to 0.1 nm

$ 7644 / Each of 1

Single Beam UV/Visible Spectrophotometer LMUS-A303

  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ± 0.5 nm
  • Wavelength Repeatability: ≤ 0.2 nm

$ 2028 / Pack of 1

Single Beam UV/Visible Spectrophotometer LMUS-C101
  • Wavelength: 190 nm to 1100 nm
  • Spectral Bandwidth: 1 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ±0.3nm
  • Wavelength Repeatability: Less than or equal to 0.1 nm

$ 6936 / Each of 1

Single Beam UV/Visible Spectrophotometer LMUS-A101
  • Wavelength: 190 nm to 1100 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ±0.1nm at 656.1nm, ±0.3nm at other wavelengths
  • Wavelength Repeatability: Less than or equal to 0.1 nm

$ 3852 / Each of 1

Single Beam UV/Visible Spectrophotometer LMUS-C103

  • Wavelength: 190 nm to 1100 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ±0.1nm at 656.1nm, ±0.3nm at other wavelengths
  • Wavelength Repeatability: Less than or equal to 0.1 nm

$ 3564 / Each of 1

Single Beam UV/Visible Spectrophotometer LMUS-A203

  • Wavelength: 190 nm to 1000 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: 1nm
  • Wavelength Repeatability: Less than or equal to 0.5 nm

$ 1692 / Each of 1

Single Beam UV/Visible Spectrophotometer LMUS-A309

  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 4 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: 1 nm
  • Wavelength Repeatability: ≤ 0.5 nm

$ 1308 / Pack of 1

Single Beam UV/Visible Spectrophotometer LMUS-A308
  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 4 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ± 1 nm
  • Wavelength Repeatability: ≤ 0.3 nm

$ 3888 / Pack of 1

Single Beam UV/Visible Spectrophotometer LMUS-A102
  • Wavelength: 190 nm to 1100 nm
  • Spectral Bandwidth: 1 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ±0.1nm at 656.1nm, ±0.3nm at other wavelengths
  • Wavelength Repeatability: Less than or equal to 0.1 nm

$ 3972 / Each of 1

Single Beam UV/Visible Spectrophotometer LMUS-B101

  • Wavelength: 190 nm to 1100 nm
  • Spectral Bandwidth: 1 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ±0.1nm at 656.1nm, ±0.3nm at other wavelengths
  • Wavelength Repeatability: Less than or equal to 0.1 nm

$ 3972 / Each of 1

Single Beam UV/Visible Spectrophotometer LMUS-A306

  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: 1 nm
  • Wavelength Repeatability: ≤ 0.2 nm

$ 1824 / Pack of 1

Single Beam UV/Visible Spectrophotometer LMUS-A304

  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ± 0.8 nm
  • Wavelength Repeatability: ≤ 0.3 nm

$ 2124 / Pack of 1

Single Beam UV/Visible Spectrophotometer LMUS-A201
  • Wavelength: 190 nm to 1020 nm
  • Spectral Bandwidth: 4 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ±2nm
  • Wavelength Repeatability: Less than or equal to 1 nm

$ 1116 / Each of 1

Single Beam UV/Visible Spectrophotometer LMUS-A202
  • Wavelength: 190 nm to 1020 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ±2nm
  • Wavelength Repeatability: Less than or equal to 1 nm

$ 1236 / Each of 1

Frequently Asked Questions

1 What is a Single Beam UV/Visible Spectrophotometer?

A Single Beam UV/Visible Spectrophotometer is an apparatus designed to measure the absorbance or transmittance of a sample at specific wavelengths in the ultraviolet and visible light spectrum.

2 How does Single Beam UV/Visible Spectrophotometer work?

It works by passing a beam of light through a sample and comparing the intensity of light before and after it passes through the sample to determine absorbance.

3 How is Single Beam UV/Visible Spectrophotometer used in pharmaceutical analysis?

In pharmaceutical analysis, it is used to determine drug concentrations, monitor compound purity, and perform dissolution and stability studies.

4 How does Single Beam UV/Visible Spectrophotometer help in water quality testing?

It helps in water quality testing by detecting contaminants like nitrates, phosphates, and heavy metals through colorimetric or direct UV absorbance methods.

5 What role does Single Beam UV/Visible Spectrophotometer play in chemical kinetics studies?

It monitors the change in absorbance over time to study reaction rates and mechanisms in chemical kinetics.

6 How does Single Beam UV/Visible Spectrophotometer assist in environmental monitoring?

It is useful in environmental monitoring for analyzing pollutants in air, water, and soil samples through absorbance-based methods.

7 How is Single Beam UV/Visible Spectrophotometer used in clinical diagnostics?

It is used in clinical diagnostics to analyze blood, urine, and serum samples for biochemical markers such as glucose, cholesterol, and enzyme activity.

8 How can Single Beam UV/Visible Spectrophotometer be used for quality control in manufacturing?

It helps in quality control by ensuring consistent color, concentration, and purity of raw materials and finished products.

9 What role does Single Beam UV/Visible Spectrophotometer play in agricultural research?

In agricultural research, it is used to analyze soil nutrients, pesticide residues, and plant pigments like chlorophyll.

10 Is Single Beam UV/Visible Spectrophotometer used in forensic science?

It is used in forensic science to analyze substances such as drugs, inks, and stains by measuring their unique absorbance spectra.