Single Beam UV/Visible Spectrophotometer LMUS-C101 offers wavelength range of 190 to 1100 nm. Built with narrow bandwidth of 1 nm for enhanced resolution. Incorporated with xenon lamp to deliver stable and full-spectrum illumination. Equipped with silicon photodiode detector for efficient signal reception. Our Spectrophotometer integrates 11-inch touch screen interface for smooth and intuitive operation.

Catalog Send Mail Whatsapp

Specifications

Wavelength 190 nm to 1100 nm
Spectral Bandwidth 1 nm
Optical System Single Beam, Grating 1200 lines/mm
Wavelength Accuracy ±0.3nm
Wavelength Repeatability Less than or equal to 0.1 nm
Photometric Range 0 to 400%T, –4 to 4A
Photometric Accuracy ±0.2%T(0 to 100%T), ±0.0005A(0 to 0.5A), ±0.0008A(0.5 to 1A)
Photometric Repeatability Less than or equal to 0.15%T (0 to 100%T), 0.0004A(0 to 0.5A), 0.0006A(0.5 to 1A)
Resolution 0.00001Abs
Stray Light Less than or equal to 0.03%T at 220nm, 360nm
Stability ±0.0001A
Baseline Flatness ±0.0004A
Noise 0.0005A at 500nm
Detector Silicon photodiode
Light Source Xenon lamp
Work Mode T, A, C, E
Scanning Speed High, Medium, Low (Max. 6000nm/min)
Cuvette Holder 10mm 4-cell holder
Output Cloud connectivity, Email, SMS, Bluetooth, Wi-Fi
Display IPAD 11-inch Touch Screen
Power Supply AC 220V/50Hz
Package Dimension 810×660×390 mm
Gross Weight 27 kg

Pricing

Product Price Unit Action
Single Beam UV/Visible Spectrophotometer LMUS-C101 $ 7225 Each of 1

Features

Low stray light and noise

Stable baseline 

Fast scanning speed

Real-time data sending

Adopts 3.0 Bluetooth protocol

Supports laser and thermal printers

Audit tracking and log inquiry functions

Standard Accessories

Model No.

Accessory

LMUS-C101-G1

10mm Glass cuvette

LMUS-C101-Q1

10mm Quartz cuvette

LMUS-C101-P1

Power cord

Optional Accessories

Model No.

Accessory

LMUS-C101-G2

5mm Glass Cuvette
LMUS-C101-G310mm Glass Cuvette
LMUS-C101-G420mm Glass Cuvette
LMUS-C101-G530mm Glass Cuvette
LMUS-C101-G650mm Glass Cuvette
LMUS-C101-G7100mm Glass Cuvette

LMUS-C101-Q2

5mm Quartz Cuvette
LMUS-C101-Q310mm Quartz Cuvette
LMUS-C101-Q420mm Quartz Cuvette
LMUS-C101-Q530mm Quartz Cuvette
LMUS-C101-Q650mm Quartz Cuvette
LMUS-C101-Q7100mm Quartz Cuvette

LMUS-C101-QM1

0.35/0.7/1.0/1.4/1.7ml Quartz Micro-Cuvette

LMUS-C101-QM2

50/100/200µl Quartz Micro-Cuvette

LMUS-C101-GM1

0.35/0.7/1.0/1.4/1.7ml Glass Micro-Cuvette

LMUS-C101-GM2

50/100/200µl Glass Micro-Cuvette

LMUS-C101-H1

10mm Manual 4-cell Holder

LMUS-C101-H2

50mm Manual 4-cell Holder

LMUS-C101-H3

100mm Manual 4-cell Holder

LMUS-C101-S1

10mm Single-hole Cell Holder

LMUS-C101-SH1

50mm Single-hole long-path cell Holder

LMUS-C101-SH2

100mm Single-hole long-path cell Holder

LMUS-C101-A1

Auto 8-cell/4-cell/5-cell Holder

LMUS-C101-F1

Film Holder

LMUS-C101-R1

Tube Rack

LMUS-C101-M1

Adjustable XY Micro Cell Holder

LMUS-C101-PS1

Peltier/Sipper System

LMUS-C101-I1

Integrating Sphere

LMUS-C101-T1

Tungsten Lamp

LMUS-C101-D1

Deuterium Lamp

LMUS-C101-X1

Xenon Lamp

LMUS-C101-TP1

Thermal Printer 

LMUS-C101-TP2

Built-in Thermal Printer

LMUS-C101-PC1

PC software

LMUS-C101-CF1

21 CFR software

Applications

Single Beam UV/Visible Spectrophotometer LMUS-C101 is ideal for DNA/protein test, kinetics, spectrum scan, multi-wavelength test, photometric, and quantitative measurement in pharmaceutical, chemical, and environmental laboratories. 

Similar Products

Single Beam UV/Visible Spectrophotometer LMUS-A301

  • Wavelength: 190 nm to 1100 nm
  • Spectral Bandwidth: 1.8 nm
  • Optical System: Single Beam, Blazed Holographic Grating 1200 lines/mm
  • Wavelength Accuracy: ±0.5nm
  • Wavelength Repeatability: Less than or equal to 0.2 nm

$ 3475 / Each of 1

Single Beam UV/Visible Spectrophotometer LMUS-A204

  • Wavelength: 190 nm to 1000 nm
  • Spectral Bandwidth: 4 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: 1nm
  • Wavelength Repeatability: Less than or equal to 0.5 nm

$ 2450 / Each of 1

Single Beam UV/Visible Spectrophotometer LMUS-A308

  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 4 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ± 1 nm
  • Wavelength Repeatability: ≤ 0.3 nm

$ 4050 / Pack of 1

Single Beam UV/Visible Spectrophotometer LMUS-A203
  • Wavelength: 190 nm to 1000 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: 1nm
  • Wavelength Repeatability: Less than or equal to 0.5 nm

$ 2562.5 / Each of 1

Single Beam UV/Visible Spectrophotometer LMUS-A102
  • Wavelength: 190 nm to 1100 nm
  • Spectral Bandwidth: 1 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ±0.1nm at 656.1nm, ±0.3nm at other wavelengths
  • Wavelength Repeatability: Less than or equal to 0.1 nm

$ 4137.5 / Each of 1

Single Beam UV/Visible Spectrophotometer LMUS-A305

  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: 1 nm
  • Wavelength Repeatability: ≤ 0.5 nm

$ 2225 / Pack of 1

Single Beam UV/Visible Spectrophotometer LMUS-A303

  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ± 0.5 nm
  • Wavelength Repeatability: ≤ 0.2 nm

$ 2912.5 / Pack of 1

Single Beam UV/Visible Spectrophotometer LMUS-A310

  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 4 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: 2 nm
  • Wavelength Repeatability: 1nm

$ 2375 / Pack of 1

Single Beam UV/Visible Spectrophotometer LMUS-C104
  • Wavelength: 190 nm to 1100 nm
  • Spectral Bandwidth: 1 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ±0.1nm at 656.1nm, ±0.3nm at other wavelengths
  • Wavelength Repeatability: Less than or equal to 0.1 nm

$ 3837.5 / Each of 1

Single Beam UV/Visible Spectrophotometer LMUS-B101
  • Wavelength: 190 nm to 1100 nm
  • Spectral Bandwidth: 1 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ±0.1nm at 656.1nm, ±0.3nm at other wavelengths
  • Wavelength Repeatability: Less than or equal to 0.1 nm

$ 4137.5 / Each of 1

Single Beam UV/Visible Spectrophotometer LMUS-A200

  • Wavelength: 195 nm to 1020 nm
  • Spectral Bandwidth: 5 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ± 2 nm
  • Wavelength Repeatability: 1 nm

$ 2012.5 / Pack of 1

Single Beam UV/Visible Spectrophotometer LMUS-C102

  • Wavelength: 190 nm to 1100 nm
  • Spectral Bandwidth: 0.1/0.2/0.5/1/2/4/5 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ±0.3nm
  • Wavelength Repeatability: Less than or equal to 0.1 nm

$ 7962.5 / Each of 1

Single Beam UV/Visible Spectrophotometer LMUS-A307

  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: 2 nm
  • Wavelength Repeatability: 1 nm

$ 2462.5 / Pack of 1

Single Beam UV/Visible Spectrophotometer LMUS-C103
  • Wavelength: 190 nm to 1100 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ±0.1nm at 656.1nm, ±0.3nm at other wavelengths
  • Wavelength Repeatability: Less than or equal to 0.1 nm

$ 3712.5 / Each of 1

Single Beam UV/Visible Spectrophotometer LMUS-A101
  • Wavelength: 190 nm to 1100 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ±0.1nm at 656.1nm, ±0.3nm at other wavelengths
  • Wavelength Repeatability: Less than or equal to 0.1 nm

$ 4012.5 / Each of 1

Frequently Asked Questions

1 What is a Single Beam UV/Visible Spectrophotometer?

A Single Beam UV/Visible Spectrophotometer is an apparatus designed to measure the absorbance or transmittance of a sample at specific wavelengths in the ultraviolet and visible light spectrum.

2 How does Single Beam UV/Visible Spectrophotometer work?

It works by passing a beam of light through a sample and comparing the intensity of light before and after it passes through the sample to determine absorbance.

3 How is Single Beam UV/Visible Spectrophotometer used in pharmaceutical analysis?

In pharmaceutical analysis, it is used to determine drug concentrations, monitor compound purity, and perform dissolution and stability studies.

4 How does Single Beam UV/Visible Spectrophotometer help in water quality testing?

It helps in water quality testing by detecting contaminants like nitrates, phosphates, and heavy metals through colorimetric or direct UV absorbance methods.

5 What role does Single Beam UV/Visible Spectrophotometer play in chemical kinetics studies?

It monitors the change in absorbance over time to study reaction rates and mechanisms in chemical kinetics.

6 How does Single Beam UV/Visible Spectrophotometer assist in environmental monitoring?

It is useful in environmental monitoring for analyzing pollutants in air, water, and soil samples through absorbance-based methods.

7 How is Single Beam UV/Visible Spectrophotometer used in clinical diagnostics?

It is used in clinical diagnostics to analyze blood, urine, and serum samples for biochemical markers such as glucose, cholesterol, and enzyme activity.

8 How can Single Beam UV/Visible Spectrophotometer be used for quality control in manufacturing?

It helps in quality control by ensuring consistent color, concentration, and purity of raw materials and finished products.

9 What role does Single Beam UV/Visible Spectrophotometer play in agricultural research?

In agricultural research, it is used to analyze soil nutrients, pesticide residues, and plant pigments like chlorophyll.

10 Is Single Beam UV/Visible Spectrophotometer used in forensic science?

It is used in forensic science to analyze substances such as drugs, inks, and stains by measuring their unique absorbance spectra.