Portable Airborne Particle Counter LMAP-B100

Portable Airborne Particle Counter LMAP-B100 offers flowrate of 28.3L/min. It allows customizable sampling of up to 99 cycles, enabling flexible monitoring schedules. Equipped with integrated temperature and humidity sensor, it provides simultaneous tracking of environmental parameters. Its six size channels, enables broad-range monitoring and analysis across different air contaminants. Our Portable Airborne Particle Counter is ideal for cleanroom monitoring, pharmaceutical production, environmental testing 

Catalog Send Mail Whatsapp

Specifications

Flow rate 28.3L/min (0.1cfm)
Particle Size 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm
Auto-clean duration Less than or equal to 10min
Particle size deviation 0.5 µm to 5 µm, less than or equal ± 30%
Particle concentration deviation 0.5 µm, less than or equal ± 30%
Repeatability accuracy Less than or equal ±10%
Working Temperature 15 to 35℃
Working Humidity 10 to 85% RH
Sampling duration Adjustable from 1 second to 99 minutes
Collection delay Less than or equal to 99s
Reading interval Less than or equal to 999s
Collection mode Continuous, less than or equal 99 times
Alarm level Class 100 to Class 300,000 or 5 to 9
Recharge duration 3 hours
Continuous runtime 8 hours
Built-in battery 220 Wh (16.8V/15Ah)
Power adapter 84 W (16.8V/5A)
Power consumption 25 W
Dimensions 460 × 265 × 420 mm
Net weight 8kg
Gross weight 8.5kg

Pricing

Product Price Unit Action
Portable Airborne Particle Counter LMAP-B100 $ 3250 Each of 1

Features

Automated Calibration System

7-Inch Color Touch Screen

Semiconductor Diode

Unit Conversion

USB Data Transfer

Dual Power Options

Applications

Portable Airborne Particle Counter LMAP-B100 is ideal for cleanroom monitoring, pharmaceutical production, semiconductor manufacturing, environmental testing, food processing, and hospital infection control.

Selection Guide

Portable Airborne Particle Counter LMAP-B100 is the perfect choice for professionals involved in cleanroom monitoring, pharmaceutical manufacturing, environmental air quality studies, and research requiring strict airborne contamination control. It is particularly suited for applications in hospitals, electronics production, HVAC testing, and aerospace environments. Researchers use it in studies focused on air pollution, occupational health, and biomedical contamination. The device supports experiments like filter efficiency testing, cleanroom validation, and laminar flow cabinet performance analysis. With its high sensitivity (detecting particles as small as 0.3 µm), portable design, and compliance with ISO and GMP standards, it is perfect for both field and laboratory use where accurate air quality monitoring is critical.

Airborne Particle Counter with temperature and humidity sensor
Airborne Particle Counter with temperature and humidity sensor

Similar Products

Portable Airborne Particle Counter LMAP-A101

  • Particle Size Channels: 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm
  • Flow Rate: 0.1 CFM ( 2.83 L/min )
  • Built-in Battery: yes
  • Battery Type: Lithium-ion
  • Test Class: Class 100 to class 300,000
Catalog

Portable Airborne Particle Counter LMAP-A300

  • Particle Size Channels: 0.1 µm, 0.2 µm, 0.3 µm, 0.5 µm, 1.0 µm, 5.0 µm
  • Flow Rate: 1 CFM (28.3 L/min)
  • Teat Way: UCL
  • Print Mode: Built-in thermal Printer
  • Working Time: 8 hours of continuous use
Catalog

Portable Airborne Particle Counter LMAP-B101

  • Particle Size Channels: 0.3µm, 0.5 µm, 0.7 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm, 10.0 µm
  • Flow Rate: 50L/min
  • Built-in Battery: yes
  • Battery Type: Lithium-ion(Optional)
  • Battery Life: >4 hours of continuous use
Catalog
Portable Airborne Particle Counter LMAP-B103
  • Particle Size: 0.3, 0.5, 1.0, 3.0, 50. 10.0 µm
  • Counting Efficiency: 0.3um: 50% ±20%>0.5um: 100% ±10%
  • Maximum Concentration: >7.4×105pcs/ft 3(2.6×107pcs/m3)
  • Light Source: laser diode
  • Sampling Flowrate: 1CFM(28.3L/min), Error±2%FS

$ 7900 / Pack of 1

Portable Airborne Particle Counter LMPC-201
  • Light source: Laser diode (lifetime greater than 30,000 hours)
  • Flow: 2.83 L/M(0.1cfm)
  • Counting efficiency: 50±10%@0.3μm, 100±10%@0.5μm
  • Measuring repeated relative deviation: ≤±10%
  • Sampling time: User-defined (1 minute to 99 minutes))

$ 4925 / Pack of 1

Portable Airborne Particle Counter LMAP-A200

  • Particle Size Channels: 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm
  • Flow Rate: 1 CFM ( 28.3 L/min )
  • Built-in Battery: yes
  • Battery Type: Lithium-ion(Optional)
  • Battery Life: >4 hours of continuous use
Catalog

Portable Airborne Particle Counter LMAP-A201

  • Particle Size Channels: 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm 0.3 µm, 0.5 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm
  • Flow Rate: 0.1 CFM (2.83 L/min)
  • Built-in Battery: yes
  • Battery Type: Lithium-ion(Optional)
  • Battery Life: >4 hours of continuous use

$ 4575 / Pack of 1

Portable Airborne Particle Counter LMAP-B102

  • Particle Size Channels: 0.3µm, 0.5 µm, 0.7 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm, 10.0 µm
  • Flow Rate: 100 L/min
  • Built-in Battery: yes
  • Battery Type: Lithium-ion(Optional)
  • Battery Life: >4 hours of continuous use

$ 13225 / Pack of 1

Portable Airborne Particle Counter LMPC-202
  • Display: Touch screen (Lcd)
  • Weight: 7.5 Kg
  • Maximum Consumption: 80W
  • Power Source: DC16.8V (Built-in Lithium Battery)
  • Size Channels: 0.5,1,3, 5, 10, 25μm

$ 12700 / Pack of 1

Portable Airborne Particle Counter LMAP-A100
  • Particle Size Channels: 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm
  • Flow Rate: 0.1 CFM ( 2.83 L/min )
  • Built-in Battery: No
  • Test Class: Class 100 to class 300,000
  • Test Period: 1 min to 10 min (10 levels)
Catalog

Frequently Asked Questions

1 What is a Portable Airborne Particle Counter LMAP-B100?

A Portable Airborne Particle Counter LMAP-B100 is a portable device that detects and displays airborne particles in various size ranges and is used for monitoring air quality in cleanrooms, HVAC systems, and controlled environments.

2 How does a Portable Airborne Particle Counter LMAP-B100 work?

A Portable Airborne Particle Counter LMAP-B100 operates on the principle of laser light scattering to detect and measure airborne particles.

3 Can Portable Airborne Particle Counter LMAP-B100 be used in pharmaceutical environments?

Portable Airborne Particle Counter LMAP-B100 ensures that particle levels meet strict regulatory standards for sterile production areas.

4 How does Portable Airborne Particle Counter LMAP-B100 assist in filter testing?

Portable Airborne Particle Counter LMAP-B100 measures particle counts before and after filters to assess their efficiency.

5 Is Portable Airborne Particle Counter LMAP-B100 useful in museums and archives?

Portable Airborne Particle Counter LMAP-B100 ensures air cleanliness to protect delicate artifacts and documents.

6 Is Portable Airborne Particle Counter LMAP-B100 applicable in aerospace manufacturing?

Portable Airborne Particle Counter LMAP-B100 helps maintain ultra-clean conditions required for assembling precision components.

7 Can Portable Airborne Particle Counter LMAP-B100 be used in food processing areas?

Portable Airborne Particle Counter LMAP-B100 monitors airborne contaminants to maintain hygiene and product safety.

8 Can Portable Airborne Particle Counter LMAP-B100 assist in outbreak response or infection control?

Portable Airborne Particle Counter LMAP-B100 tracks airborne particle trends to assess risks in healthcare or quarantine settings.

9 Is Portable Airborne Particle Counter LMAP-B100 helpful in greenhouse or vertical farming environments?

Portable Airborne Particle Counter LMAP-B100 monitors air quality to maintain optimal growing conditions and prevent airborne contamination.

10 What kind of maintenance does Portable Airborne Particle Counter LMAP-B100 require?

Routine maintenance includes regular external cleaning, annual calibration, proper storage, and running its self-cleaning cycle to maintain accuracy and performance.

11 What is a Portable Airborne Particle Counter?

A Portable Airborne Particle Counter is a mobile apparatus designed to detect and count the number and size of particles suspended in the air.

12 How does a Portable Airborne Particle Counter work?

It works by sampling air and detecting particles as they pass through a laser beam, measuring their size and quantity.

13 Can environmental conditions affect Portable Airborne Particle Counter?

High humidity and extreme temperatures can affect its readings or damage sensitive internal components.

14 What kind of maintenance does Portable Airborne Particle Counter require?

Regular maintenance includes cleaning of the apparatus, storing it properly and calibrating it annually for accurate performance.

15 Can Portable Airborne Particle Counter detect smoke or pollution?

It can detect fine particulates in smoke and pollution.

16 Can Portable Airborne Particle Counter be used in a cleanroom?

It is widely used in cleanroom environments.

17 Can Portable Airborne Particle Counter be used in a manufacturing facility?

It is commonly used in electronics, pharmaceuticals, food processing and other controlled manufacturing environments to ensure air cleanliness.

18 Can Portable Airborne Particle Counter be used to validate HEPA filters?

It is commonly used during HEPA/ULPA filter integrity testing.

19 Can Portable Airborne Particle Counter be used to measure air cleanliness in laboratories?

It is commonly used in laboratory environments in order to ensure that airborne particle levels comply with cleanliness standards necessary for research and testing.

20 Can Portable Airborne Particle Counter be used to measure air quality in vehicles?

It is suitable for measuring particulate pollution in vehicles.