Get Quote

Contact us now to receive a detailed quotation.

Low Speed Refrigerated Centrifuge LMLCR-A101

Catalog Send Mail Whatsapp

Specifications

Max. Speed 5500 rpm
Max. RCF 5310 x g
Max. Capacity 4 x 750 mL
Timer 1 min ⁓ 99 min
Temperature range -20 °C ⁓ 40 °C
Temperature accuracy ± 1.0 °C
Revolutions / min ± 10 r/min
Noise ≤ 60 dB (A)
Chamber Diameter Φ 420 mm
Power 1500 W
Voltage AC 220 ± 22 V 50 Hz 15 A
Dimension 645 x 700 x 445 mm
Weight 95 kg

Features

AC frequency conversion motor Microcomputer control with multicolor LED display Automatic RCF calculation 10 levels acceleration and deceleration control Time display in seconds for countdown less than one minute Electronic lid lock Inner chamber made of steel material Imported energy-efficient eco-friendly refrigeration system One key pre-cooling function

Rotor Selection

Model NoTypeMax. SpeedMax. RCFCapacityImage
LMLCR-A101-MR1Micro plates Rotor4000 rpm1700 x g2 x 2 x 48 Hole 
LMLCR-A101-MR2Micro plates Rotor4000 rpm2300 x g2 x 2 x 96 Hole 
LMLCR-A101-MR3Micro plates Rotor4000 rpm3500 x g4 x 2 x 96 Hole 
LMLCR-A101-SR1Swing Rotor4000 rpm2810 x g8 x 50 mL 
LMLCR-A101-SR2Swing Rotor4000 rpm2810 x g16 x 10 / 15 mL 
LMLCR-A101-SR3Swing Rotor4000 rpm2810 x g24 x 10 / 15 mL 
LMLCR-A101-SR4Swing Rotor4000 rpm2810 x g32 x 10 / 15 mL 
LMLCR-A101-SR5Swing Rotor4000 rpm2810 x g48 x 5 / 7 mL 
LMLCR-A101-SR6Swing Rotor4000 rpm2810 x g64 x 5 /7 mL 
LMLCR-A101-SR7Swing Rotor4000 rpm2810 x g72 x 5 / 7 mL 
LMLCR-A101-SR8Swing Rotor4000 rpm3500 x g4 x 250 mL 
LMLCR-A101-SR9Swing Rotor4000 rpm3500 x g4 x 250 mL / Sharp bottom 
LMLCR-A101-SR10Swing Rotor4000 rpm3500 x g6 x 250 mL 
LMLCR-A101-SR11Swing Rotor4000 rpm3850 x g4 x 500 mL 
LMLCR-A101-SR12Swing Rotor4000 rpm3850 x g4 x 750 mL 
LMLCR-A101-SR13Swing Rotor4000 rpm3850 x g48 x 15 mL 
LMLCR-A101-SR14Swing Rotor4000 rpm3850 x g96 x 5 / 7 mL 
LMLCR-A101-SR15Swing Rotor4000 rpm3850 x g120 x 5 / 7 mL 
LMLCR-A101-SR16Swing Rotor5000 rpm4390 x g4 x 100 mL 
LMLCR-A101-SR17Swing Rotor5500 rpm5310 x g4 x 50 mL 

Similar Products

Low Speed Refrigerated Centrifuge LMLCR-B100

  • Max. Speed: 5000 rpm
  • Max. RCF: 4390 x g
  • Max. Capacity: 4 x 750 mL
  • Timer: 1 min ⁓ 99 min
  • Temperature range: -20 °C ⁓ 40 °C

Low Speed Refrigerated Centrifuge LMLCR-A102

  • Max. Speed: 6500 rpm
  • Max. RCF: 5190 x g
  • Max. Capacity: 4 x 250 mL
  • Timer: 1 min ⁓ 99 min
  • Temperature range: -20 °C ⁓ 40 °C

Low Speed Refrigerated Centrifuge LMLCR-B103

  • Maximum Speed: 8000 rpm
  • Maximum RCF: 12166 × g
  • Maximum Capacity: 6 × 2400 mL
  • Timer: 1 min to 23 h 59 min
  • Temperature range: -20 °C to 40 °C
Low Speed Refrigerated Centrifuge LMLCR-B104
  • Max. Speed: 8000rpm
  • Max. RCF: 14550×g
  • Max. Capacity: 8×2000ml (16×500ml blood bag)
  • Time Range: 1- 9h59min
  • Noise: ≤ 65 dB
Low Speed Refrigerated Centrifuge LMLCR-A100
  • Max. Speed: 5500 rpm
  • Max. RCF: 4900 x g
  • Max. Capacity: 4 x 250 mL
  • Timer: 1 min ⁓ 99 min
  • Temperature range: -20 °C ⁓ 40 °C

Low Speed Refrigerated Centrifuge LMLCR-B102

  • Max. Speed: 6500 rpm
  • Max. RCF: 6680 x g
  • Max. Capacity: 6 x 1000 mL
  • Timer: 1 min ⁓ 2 h 59 min
  • Temperature range: -20 °C ⁓ 40 °C

Low Speed Refrigerated Centrifuge LMLCR-B101

  • Max. Speed: 5500 rpm
  • Max. RCF: 5310 x g
  • Max. Capacity: 6 x 500 mL / 4 x 750 mL
  • Timer: 1 min ⁓ 99 min
  • Temperature range: -20 °C ⁓ 40 °C

Low Speed Refrigerated Centrifuge LMLCR-A103

  • Max. Speed: 6500 rpm
  • Max. RCF: 5310 x g
  • Max. Capacity: 4 x 750 mL
  • Timer: 1 min ⁓ 99 min
  • Temperature range: -20 °C ⁓ 40 °C

Frequently Asked Questions

1 What is a Low Speed Refrigerated Centrifuge?

A Low Speed Refrigerated Centrifuge is a laboratory apparatus designed to separate components of a mixture at relatively low rotational speeds.

2 What types of samples can be processed in Low Speed Refrigerated Centrifuge?

It is commonly used for blood samples, cell cultures, urine and other temperature-sensitive biological materials.

3 What safety features are available in Low Speed Refrigerated Centrifuge?

Key safety features include automatic lid lock, imbalance detection, over-speed protection, and temperature control alarms.

4 Can Low Speed Refrigerated Centrifuge be used for urine sample analysis?

It is commonly used to sediment urinary particles such as cells, casts, and crystals for microscopic examination.

5 Is Low Speed Refrigerated Centrifuge suitable for cell harvesting?

It is ideal for harvesting cells from culture media since the low speed prevents cell damage and the refrigeration maintains sample integrity.

6 Can Low Speed Refrigerated Centrifuge be used in clinical diagnostics labs?

It is widely used for routine separation of body fluids, preparation of samples for biochemical assays and temperature-controlled handling of diagnostic samples.

7 Can Low Speed Refrigerated Centrifuge be used in environmental labs?

It is used to separate particulate matter from water and soil extracts during sample preparation.

8 Can Low Speed Refrigerated Centrifuge be used for immunology applications?

It is used to separate serum for antibody testing or to pellet cells for immunoassays thereby helping in maintaining antigen-antibody stability with controlled temperature.

9 Can Low Speed Refrigerated Centrifuge be used in biotechnology for fermentation process?

It is used to collect biomass from fermentation broths before downstream processing, with temperature control preserving cellular proteins and enzymes.

10 Can Low Speed Refrigerated Centrifuge be used in forensic labs?

It is used to separate biological samples such as blood or semen before DNA analysis.