Get Quote

Contact us now to receive a detailed quotation.

Low Speed Centrifuge LMLC-A108

Catalog Send Mail Whatsapp

Specifications

Max. Speed 5500 rpm
Max. RCF 5310 x g
Max. Capacity 6 x 500 mL / 4 x 750 mL
Timer 1 min ~ 99 min
Revolutions / min ± 10 rpm
Noise ≤ 60 dB (A)
Chamber Diameter Φ 500 mm
Power 800 W
Voltage AC 220 ± 22 V, 50 Hz, 15 A
Dimensions 825 x 625 x 910 mm
Net Weight 130 Kg

Features

Microcomputer control with LED display AC frequency conversion motor Provision to revise parameters during operation 10 level acceleration and deceleration function control Over speed, over heat and imbalance protections with auto lid lock Electronic lid lock with full steel inner cavity protective cover

Rotor Selection

Model NoTypeMax. SpeedMax. RCFCapacityImage
LMLC-A108-SR1Swing Rotor4000 rpm3500 x g4 x 250 mL 
LMLC-A108-SR2Swing Rotor4000 rpm3850 x g4 x 250 mL (Sharp bottom) 
LMLC-A108-SR3Swing Rotor4000 rpm3580 x g4 x 500 mL 
LMLC-A108-SR4Swing Rotor4000 rpm3580 x g4 x 750 mL 
LMLC-A108-SR5Swing Rotor4000 rpm3500 x g6 x 250 mL 
LMLC-A108-SR6Swing Rotor4000 rpm3890 x g6 x 500 mL 
LMLC-A108-SR7Swing Rotor4000 rpm2810 x g8 x 50 mL 
LMLC-A108-SR8Swing Rotor4000 rpm2810 x g8 x 100 mL 
LMLC-A108-SR9Swing Rotor4000 rpm2810 x g16 x 10 / 15 mL 
LMLC-A108-SR10Swing Rotor4000 rpm2810 x g24 x 10 / 15 mL 
LMLC-A108-SR11Swing Rotor4000 rpm2810 x g32 x 10 / 15 mL 
LMLC-A108-SR12Swing Rotor4000 rpm3580 x g48 x 15 mL (Sharp bottom) 
LMLC-A108-SR13Swing Rotor4000 rpm3500 x g72 x 5 / 7 mL 
LMLC-A108-SR14Swing Rotor4000 rpm3580 x g96 x 5 / 7 mL 
LMLC-A108-SR15Swing Rotor5500 rpm5310 x g4 x 50 mL 
LMLC-A108-SR16Swing Rotor5500 rpm5310 x g4 x 100 mL 
LMLC-A108-ER1Elisa Plate Rotor4000 rpm1700 x g2 x 2 x 48 Hole 
LMLC-A108-ER2Elisa Plate Rotor4000 rpm2300 x g2 x 2 x 96 Hole 
LMLC-A108-ER3Elisa Plate Rotor4000 rpm3550 x g4 x 2 x 96 Hole 

Similar Products

Low Speed Centrifuge LMLSC-A101

  • Maximum Speed: 5000 r/min
  • Maximum RCF: 4360 × g
  • Time Range: 0 to 999 min
  • Power Supply: AC 220V, 50 Hz, 8A
  • Dimension: 510 × 410 × 310 mm

Low Speed Centrifuge LMLC-B101

  • Max Speed: 6000r/min
  • Max Volume: 4×800ml
  • Timer: 0 to 99min
  • Speed Accuracy: ±20r/min
  • Max RCF: 4730 ×g

Low Speed Centrifuge LMLC-A303

  • Speed Range: 500-4000rpm
  • Force: 2075 ×g
  • Semidiameter Of Rotor: 11.6 cm
  • Rotor Capacity: 15ml× 12 Centrifuge tube 2/5/10ml× 12 Blood tube
  • Timing Range: 30s ~ 59min50s
Low Speed Centrifuge LMLC-A302
  • Speed Range: 500-4000rpm
  • Force: 1967 ×g
  • Rotor Capacity: 15ml× 8 Centrifuge tube 2/5/10ml× 8 Blood tube
  • Semidiameter Of Rotor: 11cm
  • Timing Range: 30s ~ 59min50s
Low Speed Centrifuge LMLC-A304
  • Speed Range: 500-4000rpm
  • Force: 2146 ×g
  • Rotor Capacity: 15/50ml× 6 Centrifuge tube 2/5/10ml× 6 Blood tube
  • Semidiameter Of Rotor: 12cm
  • Timing Range: 30s ~ 59min50s

Low Speed Centrifuge LMLSC-A100

  • Maximum Speed: 5000 r/min
  • Maximum RCF: 4360 × g
  • Time Range: 0 to 999 min
  • Power Supply: AC 220V, 50Hz, 8A
  • Dimension: 510 × 410 × 310 mm

Low Speed Centrifuge LMLC-A306

  • Speed Range: 500-4000rpm
  • Force: 2164 ×g
  • Rotor Capacity: 2/5/10ml× 24 Blood tube
  • Semidiameter Of Rotor: 12.1 cm
  • Timing Range: 30s ~ 59min50s

Low Speed Centrifuge LMLC-A104

  • Maximum Speed: 6000 rpm
  • Maximum RCF: 4430 × g
  • Maximum Capacity: 4 × 100 mL
  • Timer: 1 min to 99 min
  • Revolutions / min: ± 10 rpm
Low Speed Centrifuge LMLC-A305
  • Speed Range: 500-4000rpm
  • Force: 2182 ×g
  • Rotor Capacity: 2/5/10ml× 18 Blood tube
  • Semidiameter Of Rotor: 12.2 cm
  • Timing Range: 30s ~ 59min50s
Low Speed Centrifuge LMLC-A105
  • Maximum Speed: 6500 rpm
  • Maximum RCF: 5190 × g
  • Maximum Capacity: 4 × 250 mL
  • Timer: 1 min to 99 min
  • Revolutions / min: ± 10 rpm

Low Speed Centrifuge LMLC-A103

  • Maximum Speed: 5500 rpm
  • Maximum RCF: 5310 × g
  • Maximum Capacity: 4 × 750 mL
  • Timer: 1 min to 99 min
  • Revolutions / min: ± 10 rpm

Low Speed Centrifuge LMLC-A301

  • Speed Range: 500-5000rpm
  • Force: 2683 ×g
  • Rotor Capacity: 15ml× 4 Centrifuge tube 2/5/10ml× 8 Blood tube
  • Increment: 100rpm
  • Timing Range: 30s ~ 59min50s

Low Speed Centrifuge LMLC-A107

  • Maximum Speed: 5000 rpm
  • Maximum RCF: 4390 × g
  • Maximum Capacity: 4 × 750 mL
  • Timer: 1 min to 99 min 59 s
  • Revolutions / min: ± 10 rpm
Low Speed Centrifuge LMLC-A109
  • Max. Speed: 6500 rpm
  • Max. RCF: 6680 x g
  • Max. Capacity: 6 x 1000 mL
  • Timer: 1 min ~ 23 h 59 min
  • Revolutions / min: ± 10 rpm
Low Speed Centrifuge LMLC-A102
  • Maximum Speed: 5500 rpm
  • Maximum RCF: 4900 × g
  • Maximum Capacity: 4 × 250 mL
  • Timer: 1 min to 99 min
  • Revolutions / min: ± 10 rpm

Frequently Asked Questions

1 What is a Low Speed Centrifuge?

A Low Speed Centrifuge is a laboratory apparatus designed to separate components of a liquid based on density by spinning them at relatively low speeds.

2 What kind of maintenance does Low Speed Centrifuge require?

Regular maintenance includes cleaning of rotor, balancing of samples and inspecting components for wear.

3 Is Low Speed Centrifuge suitable for urine sedimentation?

It is ideal for sedimenting urine samples to help analyze cells, crystals, and other particles present in the urine.

4 Can Low Speed Centrifuge be used for cell harvesting?

It is widely used for harvesting cells from culture media in biological research and cell biology applications.

5 Can Low Speed Centrifuge be used for clinical diagnostics?

It is frequently used in clinical diagnostics for separating blood and other biological samples for analysis.

6 Can Low Speed Centrifuge be used for PCR preparation?

It is used in the preparation of samples for PCR by pelleting cellular components or precipitating DNA from solution before amplification.

7 Is Low Speed Centrifuge suitable for separating plasma from blood?

It is commonly used in clinical labs to separate plasma from whole blood by spinning at low speeds to prevent cell disruption while isolating plasma.

8 Can Low Speed Centrifuge be used for harvesting yeast cells?

It is ideal for pelleting yeast cells from liquid cultures in fermentation studies or microbiological research.

9 Can Low Speed Centrifuge help in isolating plasma cells from bone marrow?

It is used in hematology to separate plasma cells from bone marrow or blood samples based on density.

10 Can Low Speed Centrifuge be used in vaccine production?

It is used for separating cells and proteins during various stages of vaccine production.