Get Quote

Contact us now to receive a detailed quotation.

Need quick help? Chat with us on WhatsApp:

WhatsApp QR Code

OR

Atomic Absorption Spectrophotometer LMAAS-A103

Atomic Absorption Spectrophotometer LMAAS-A103 is equipped with a double-beam optical system, that operates across a broad wavelength range of 185 to 900 nm. It features flame and graphite furnace atomizers for analyzing varying concentrations of elements. It offers a maximum temperature of up to 3000°C, with ultra-sensitive detection limits of ≤ 0.8 pg for Cd and ≤ 5 pg for Cu. Integrated with a fully automatic eight-lamp position system for a wide range of elements and offers high throughput efficiency.

Catalog Send Mail Whatsapp

Specifications

Optical System Double Beam
Monochromator Czerny-Turner type, focal lengths at 350mm
Grating Grating 1800 lines/mm, scintillation wavelength 250nm
Spectral Bandwidth 0.1, 0.2, 0.4, 0.7, 1.4, 2 nm Automated slit selection
Wavelength Range 185 to 900 nm
Wavelength Accuracy 0.15 nm
Wavelength Repeatability ≤ 0.05 nm
Spectral Bandwidth Deviation ± 0.02 nm
Lamp Stand 8
Element Lamp Type Cu lamp
Reading Mode Transmittance, absorbance, concentration
Photometric Range 0 to 125 %, - 0.1 to 3.00 A
Static Baseline Drift (Cu) ± 0.003A/30min
Dynamic Baseline Drift (Cu) ± 0.005A/15min
Background Correction Deuterium lamp ≥ 40 x (1Abs)
Characteristic Concentration ≤ 0.035 ug/ml
Detection Limit (Cu) ≤ 0.004 ug/ml
Repeatability (Cu) RSD ≤ 0.5%
Acetylene Flow Control Auto 12-Level
Air Assist Control Auto 4-Level
Burner Lift Automatic lifting
Burner Head Titanium 100mm burner
Nebulizer High-efficiency glass nebulizer
Spray Chamber Corrosion-resistant material spray chamber
Safety Protection Automatically cut off gas in case of low pressure, power failure, flame out, or burner mismatched
Characteristic Amount Cd ≤ 0.8pg, Cu ≤ 20pg
Detection Limit Cd ≤ 1.0pg, Cu ≤ 5pg
Repeatability (Cd) RSD ≤ 2.5%
Heating Range of Graphite Furnace Room temperature to 3000℃
High Power Heating Range 1500 to 3000℃
Slope and Holding Time 1s to 255s
Heating Rate Maximum heating rate 2000°C/s
Atomization Heating Mode Light-controlled heating, Time-controlled heating, General heating
Protective Gas Flow Outside Pipe 1 L/min
Protective Gas Flow Inside Pipe 4-speed adjustable (0, 50, 200, 250ml/min flow)
Data Processing Cooling water flow, Protective gas pressure, Furnace body temperature, Power supply temperature, Graphite furnace installation alarm
External connect Measuring Method, Concentration Calculation Method, Repeat Measurement Times, Report printing
Ambient Temp Computer
Ambient Humidity 10℃ to 30℃
Alarm Functions 40% to 85%
Power Insufficient cooling water flow, insufficient argon pressure, excessive temperature of the graphite furnace, abnormal power supply temperature, and poor contact during graphite tube installation
Dimension (W×D×H) 220V, 50/60HZ
Packaging Dimension (W×D×H) 830 × 650 × 560 mm
Weight 110 kg

Pricing

Product Price Unit Action
Atomic Absorption Spectrophotometer LMAAS-A103 $ 26600 Pack of 1

Features

Automatically switchable test modes

Incorporated with titanium burner

Multiple alarm functions

Acetylene leakage monitoring

Automatic wavelength scanning and peak search

Users need to furnish their own argon gas, gas tanks, and pressure-reducing valves.

Standard Accessories

Software Cd Hollow cathode lamp Pipette

Optional Accessories

Model No

Accessory Name

Unit

Quantity

LMAAS-A103-A1

Argon pressure reducer

Each

1

LMAAS-A103-L1

Laughing gas module

Each

1

Applications

Atomic Absorption Spectrophotometer is designed to measure the concentration of elements and is widely utilized in environmental testing, clinical laboratories, pharmaceutical analysis, food and beverage industry.

Similar Products

Atomic Absorption Spectrophotometer LMAAS-A106

  • Optical Type: Double beam
  • Atomizer: Flame atomizer
  • Monochromator: Czerny-Turner type, focal length at 350mm
  • Wavelength Range: 190 to 900 nm
  • Wavelength Accuracy: ±0.15nm

$ 23000 / Each of 1

Atomic Absorption Spectrophotometer LMAAS-A100

  • WL Range: 190 to 900 nm
  • WL Accuracy: 0.5 nm
  • Spectrum Bandwidth: 0.2nm, 0.4nm, 0.7nm,1.4nm,2.4nm,5.0nm
  • Resolution: 
  • Base line stability: 0.004Abs/30min

$ 12450 / Each of 1

Atomic Absorption Spectrophotometer LMAAS-A110

  • Optical Type: Double beam
  • Atomizer: Flame and Graphite furnace
  • Monochromator: Czerny-Turner type, focal length at 350mm
  • Wavelength Range: 190 to 900 nm
  • Wavelength Accuracy: ±0.15nm

$ 45137.5 / Each of 1

Atomic Absorption Spectrophotometer LMAAS-A108
  • Optical Type: Single beam
  • Atomizer: Graphite furnace
  • Monochromator: Czerny-Turner type, focal length at 350mm
  • Wavelength Range: 190 to 900 nm
  • Wavelength Accuracy: ±0.2nm

$ 28750 / Each of 1

Atomic Absorption Spectrophotometer LMAAS-A109
  • Optical Type: Single beam
  • Atomizer: Flame and Graphite furnace
  • Monochromator: Czerny-Turner type, focal length at 350mm
  • Wavelength Range: 190 to 900 nm
  • Wavelength Accuracy: ±0.2nm

$ 38012.5 / Each of 1

Atomic Absorption Spectrophotometer LMAAS-A105

  • Optical Type: Single beam
  • Atomizer: Flame atomizer
  • Monochromator: Czerny-Turner type, focal length at 350mm
  • Wavelength Range: 190 to 900 nm
  • Wavelength Accuracy: ±0.2nm

$ 19862.5 / Each of 1

Atomic Absorption Spectrophotometer LMAAS-A107

  • Optical Type: Single beam
  • Atomizer: Graphite furnace
  • Monochromator: Czerny-Turner type, focal length at 350mm
  • Wavelength Range: 190 to 900 nm
  • Wavelength Accuracy: ±0.3nm

$ 26137.5 / Each of 1

Atomic Absorption Spectrophotometer LMAAS-A104

  • Optical Type: Single beam
  • Atomizer: Flame atomizer
  • Monochromator: Czerny-Turner type, focal length at 350mm
  • Wavelength Range: 190 to 900 nm
  • Wavelength Accuracy: ±0.3nm

$ 18300 / Each of 1

Atomic Absorption Spectrophotometer LMAAS-A101
  • Wavelength range: 190 to 900 nm
  • Light source: Cathode lamp
  • Lamp holder: 8-lamp turret automatically rotates and aligns
  • Lamp current range: 0 to 15 mA
  • Optical system: Czerny-Turner monochromator

$ 28550 / Each of 1

Atomic Absorption Spectrophotometer LMAAS-A102
  • Spectral range: 190 to 900 nm
  • Spectral bandwidth: 0.1 nm0.2 nm0.4 nm1.0 nm2.0 nm
  • Wavelength accuracy: ± 0.15 nm
  • Wavelength repeatability: ≤ 0.04 nm
  • Baseline stability: ≤ 0.002 Abs / 30 min

$ 22962.5 / Each of 1

Frequently Asked Questions

1 What is an Atomic Absorption Spectrophotometer?

An Atomic Absorption Spectrophotometer is an apparatus designed to measure the concentration of elements by detecting the absorption of optical radiation (light) by free atoms in the gaseous state.

2 How does Atomic Absorption Spectrophotometer work?

It works by measuring the absorption of light by vaporized atoms to determine the concentration of specific elements.

3 What elements can be detected using Atomic Absorption Spectrophotometer?

It can detect metals such as lead, copper, zinc, iron, calcium, and magnesium.

4 How is Atomic Absorption Spectrophotometer used in environmental analysis?

It is used in environmental analysis to detect trace metals like lead, mercury, and cadmium in water, soil, and air samples.

5 What is the role of Atomic Absorption Spectrophotometer in food safety testing?

It plays a vital role in food safety testing by measuring toxic metal residues such as arsenic and lead in food products.

6 Can Atomic Absorption Spectrophotometer be used in pharmaceutical industry?

In pharmaceutical industry, it is used to ensure raw materials and finished products meet safety standards by analyzing metal content.

7 Can Atomic Absorption Spectrophotometer be used in mining applications?

It is used in mining to analyze ore samples for valuable metals like gold, silver, and copper.

8 How is Atomic Absorption Spectrophotometer used in agriculture?

It is used in agriculture to monitor nutrient levels and detect toxic metals in soil, water, and fertilizers.

9 Can Atomic Absorption Spectrophotometer be used in forensic science?

In forensic science, it is used to detect trace metals in evidence such as gunshot residues or poisoned tissues.

10 How does Atomic Absorption Spectrophotometer assist in quality control in manufacturing?

It assists in quality control by verifying metal content in materials used in electronics, automotive, and metal finishing industries.