Get Quote
Contact us now to receive a detailed quotation.
Overview
Atomic Absorption Spectrophotometer LMAAS-A103 is equipped with a double-beam optical system, that operates across a broad wavelength range of 185 to 900 nm. It features flame and graphite furnace atomizers for analyzing varying concentrations of elements. It offers a maximum temperature of up to 3000°C, with ultra-sensitive detection limits of ≤ 0.8 pg for Cd and ≤ 5 pg for Cu. Integrated with a fully automatic eight-lamp position system for a wide range of elements and offers high throughput efficiency.
Features :
Automatically switchable test modes
Incorporated with titanium burner
Multiple alarm functions
Acetylene leakage monitoring
Automatic wavelength scanning and peak search
Users need to furnish their own argon gas, gas tanks, and pressure-reducing valves.
Specifications :
| Optical System | Double Beam |
| Monochromator | Czerny-Turner type, focal lengths at 350mm |
| Grating | Grating 1800 lines/mm, scintillation wavelength 250nm |
| Spectral Bandwidth | 0.1, 0.2, 0.4, 0.7, 1.4, 2 nm Automated slit selection |
| Wavelength Range | 185 to 900 nm |
| Wavelength Accuracy | 0.15 nm |
| Wavelength Repeatability | ≤ 0.05 nm |
| Spectral Bandwidth Deviation | ± 0.02 nm |
| Lamp Stand | 8 |
| Element Lamp Type | Cu lamp |
| Reading Mode | Transmittance, absorbance, concentration |
| Photometric Range | 0 to 125 %, - 0.1 to 3.00 A |
| Static Baseline Drift (Cu) | ± 0.003A/30min |
| Dynamic Baseline Drift (Cu) | ± 0.005A/15min |
| Background Correction | Deuterium lamp ≥ 40 x (1Abs) |
| Characteristic Concentration | ≤ 0.035 ug/ml |
| Detection Limit (Cu) | ≤ 0.004 ug/ml |
| Repeatability (Cu) | RSD ≤ 0.5% |
| Acetylene Flow Control | Auto 12-Level |
| Air Assist Control | Auto 4-Level |
| Burner Lift | Automatic lifting |
| Burner Head | Titanium 100mm burner |
| Nebulizer | High-efficiency glass nebulizer |
| Spray Chamber | Corrosion-resistant material spray chamber |
| Safety Protection | Automatically cut off gas in case of low pressure, power failure, flame out, or burner mismatched |
| Characteristic Amount | Cd ≤ 0.8pg, Cu ≤ 20pg |
| Detection Limit | Cd ≤ 1.0pg, Cu ≤ 5pg |
| Repeatability (Cd) | RSD ≤ 2.5% |
| Heating Range of Graphite Furnace | Room temperature to 3000℃ |
| High Power Heating Range | 1500 to 3000℃ |
| Slope and Holding Time | 1s to 255s |
| Heating Rate | Maximum heating rate 2000°C/s |
| Atomization Heating Mode | Light-controlled heating, Time-controlled heating, General heating |
| Protective Gas Flow Outside Pipe | 1 L/min |
| Protective Gas Flow Inside Pipe | 4-speed adjustable (0, 50, 200, 250ml/min flow) |
| Data Processing | Cooling water flow, Protective gas pressure, Furnace body temperature, Power supply temperature, Graphite furnace installation alarm |
| External connect | Measuring Method, Concentration Calculation Method, Repeat Measurement Times, Report printing |
| Ambient Temp | Computer |
| Ambient Humidity | 10℃ to 30℃ |
| Alarm Functions | 40% to 85% |
| Power | Insufficient cooling water flow, insufficient argon pressure, excessive temperature of the graphite furnace, abnormal power supply temperature, and poor contact during graphite tube installation |
| Dimension (W×D×H) | 220V, 50/60HZ |
| Packaging Dimension (W×D×H) | 830 × 650 × 560 mm |
| Weight | 110 kg |
Standard Accessories :
Software Cd Hollow cathode lamp Pipette
Optional Accessories :
Model No | Accessory Name | Unit | Quantity |
LMAAS-A103-A1 | Argon pressure reducer | Each | 1 |
LMAAS-A103-L1 | Laughing gas module | Each | 1 |
Applications :
Atomic Absorption Spectrophotometer is designed to measure the concentration of elements and is widely utilized in environmental testing, clinical laboratories, pharmaceutical analysis, food and beverage industry.