Get Quote

Contact us now to receive a detailed quotation.

Need quick help? Chat with us on WhatsApp:

WhatsApp QR Code

OR

Atomic Absorption Spectrophotometer LMAAS-A107

Atomic Absorption Spectrophotometer LMAAS-A107 offers wavelength range of 190 to 900nm. It ensures efficient atomization with graphite furnace for trace element analysis. Incorporates longitudinally heated graphite tube, enhancing temperature uniformity. Built with gas control module, it regulates internal and external flow rates. Our Spectrophotometer with advanced RGWIN AAS software enables seamless operation and data management.

Catalog Send Mail Whatsapp

Specifications

Optical Type Single beam
Atomizer Graphite furnace
Monochromator Czerny-Turner type, focal length at 350mm
Wavelength Range 190 to 900 nm
Wavelength Accuracy ±0.3nm
Wavelength Repeatability ±0.1nm
Grating Holographic diffraction grating with 1800 lines/mm
Slits 0.1, 0.2, 0.4, 0.7, 1.4, 2.0nm
Lamp Holder Automated 4 lamp turret
Detector Wide range UV-sensitive photomultiplier tube
Reading Mode Transmittance(T), Absorbance(A), Concentration(C)
Photometric Range 0 to 125%, -0.1 to 3.00A
Static Baseline Drift (Cu) Less than 0.004A/30 min
Dynamic Baseline Drift Less than 0.006A/15min
Background Correction Deuterium background correction
Characteristic Mass Cd less than 1pg, Cu less than 22pg
Detection Limit Cd less than 1.5pg, Cu less than 20pg
Repeatability (Cu) RSD less than 4%
Ambient Temperature 3000oC
Ramp and holding time 1 to 255s
Heating rate Maximum linear heating rate 2000oC/s
Heating method Light-controlled heating, Time-controlled heating, General heating
Gas flow rate inside tube 1L/min
Gas flow rate outside tube 0, 50, 200, 250ml/min
Safety Protection Water flow sensor, Argon pressure sensor, Furnace body temperature sensor, Graphite tube installation self-inspection
Software RGWIN AAS software package
Analytical Method Flame AA, Flame AE, Hydride generation
Concentration Calculation Method Standard curve, Standard Addition, Interpolation
Repeated Measurement Times 1-30 times, Average, SD and RSD
QA/QC Function Correlation coefficient, SD & RSD
Communication Port Standard RS-232
Working Environment Temperature 10-35 °C, Humidity less than 85%
Power Supply 110/220V, 50/60Hz
Dimension(W×D×H) 850×650×550mm
Weight 100KG

Pricing

Product Price Unit Action
Atomic Absorption Spectrophotometer LMAAS-A107 $ 26137.5 Each of 1

Features

Automated slit selection 

Deuterium background correction

Holographic diffraction grating

Water flow and argon pressure sensor

Vertical 4-lamp turret 

Standard Accessories

Accessory

Unit

Quantity

Main unit

Each

1

Power cable 

Each

1

Data cable

Each

1

Screw driver

Each

1

Cu Hollow cathode lamp

Each

1

Cd Hollow cathode lamp

Each

1

USB (manual and software)

Each

1

5A fuse

Each

3

Argon pressure reducing valve connector

Each

1

Graphite tube

Each

5

High power socket

Each

1

6×4mm transparent argon tube (10m)

Each

1

5 to 50µl Pipette

Each

1

200µl Pipette tip (1000pc/bag)

Pack 

1

6×10mm cooling water tube (6m)

Each 

1

Graphite furnace camera connection cable

Each 

1

Optional Accessories

Model No

Accessory

Unit

Quantity

LMAAS-A107-W1

Circulation Cooling Water System

Each

1

LMAAS-A107-G1

Graphite Tube

Each

1

LMAAS-A107-C1

Camera for Graphite Tube

Each

1

LMAAS-A107-A1

Auto Sampler

Each

1

LMAAS-A107-D1

Deuterium Lamp

Each

1

LMAAS-A107-L1

Hollow Cathode Lamp (Al, Ba, Bi, Ca, Co, Cr, Cd, Cu, Fe, Hg, K, Li, Mg, Mn, Mo, Na, Ni, Pb, Sb, Sn, Sr. Ti, Zr)

Each

1

LMAAS-A107-L2

Hollow Cathode Lamp (Ag, As, Se, Si, Te, V, W)

Each

1

LMAAS-A107-L3

Hollow Cathode Lamp (B, P, Ge, Zr)

Each

1

LMAAS-A107-L4

Hollow Cathode Lamp (Be)

Each

1

LMAAS-A107-L5

Hollow Cathode Lamp (Au)

Each

1

LMAAS-A107-L6

Hollow Cathode Lamp (Rb)

Each

1

LMAAS-A107-L7

Hollow Cathode Lamp (Cs)

Each

1

Applications

Atomic Absorption Spectrophotometer LMAAS-A107 is ideal for ultra-trace metal analysis in biological samples, environmental monitoring, pharmaceuticals, food safety, forensic investigations, and industrial quality control.

Similar Products

Atomic Absorption Spectrophotometer LMAAS-A110

  • Optical Type: Double beam
  • Atomizer: Flame and Graphite furnace
  • Monochromator: Czerny-Turner type, focal length at 350mm
  • Wavelength Range: 190 to 900 nm
  • Wavelength Accuracy: ±0.15nm

$ 45137.5 / Each of 1

Atomic Absorption Spectrophotometer LMAAS-A108

  • Optical Type: Single beam
  • Atomizer: Graphite furnace
  • Monochromator: Czerny-Turner type, focal length at 350mm
  • Wavelength Range: 190 to 900 nm
  • Wavelength Accuracy: ±0.2nm

$ 28750 / Each of 1

Atomic Absorption Spectrophotometer LMAAS-A105

  • Optical Type: Single beam
  • Atomizer: Flame atomizer
  • Monochromator: Czerny-Turner type, focal length at 350mm
  • Wavelength Range: 190 to 900 nm
  • Wavelength Accuracy: ±0.2nm

$ 19862.5 / Each of 1

Atomic Absorption Spectrophotometer LMAAS-A102
  • Spectral range: 190 to 900 nm
  • Spectral bandwidth: 0.1 nm0.2 nm0.4 nm1.0 nm2.0 nm
  • Wavelength accuracy: ± 0.15 nm
  • Wavelength repeatability: ≤ 0.04 nm
  • Baseline stability: ≤ 0.002 Abs / 30 min

$ 22962.5 / Each of 1

Atomic Absorption Spectrophotometer LMAAS-A101
  • Wavelength range: 190 to 900 nm
  • Light source: Cathode lamp
  • Lamp holder: 8-lamp turret automatically rotates and aligns
  • Lamp current range: 0 to 15 mA
  • Optical system: Czerny-Turner monochromator

$ 28550 / Each of 1

Atomic Absorption Spectrophotometer LMAAS-A103

  • Optical System: Double Beam
  • Monochromator: Czerny-Turner type, focal lengths at 350mm
  • Grating: Grating 1800 lines/mm, scintillation wavelength 250nm
  • Spectral Bandwidth: 0.1, 0.2, 0.4, 0.7, 1.4, 2 nm Automated slit selection
  • Wavelength Range: 185 to 900 nm

$ 26600 / Pack of 1

Atomic Absorption Spectrophotometer LMAAS-A100

  • Wavelength Range: 190 – 900 nm
  • Spectral Bandwidth: 0.2, 0.4, 1.0, 2.0 nm (selectable)
  • Wavelength Accuracy: ±0.10 nm
  • Wavelength Repeatability: 0.05 nm
  • Detection Limit (Cu): 0.003 μg/ml

$ 12450 / Each of 1

Atomic Absorption Spectrophotometer LMAAS-A109

  • Optical Type: Single beam
  • Atomizer: Flame and Graphite furnace
  • Monochromator: Czerny-Turner type, focal length at 350mm
  • Wavelength Range: 190 to 900 nm
  • Wavelength Accuracy: ±0.2nm

$ 38012.5 / Each of 1

Atomic Absorption Spectrophotometer LMAAS-A106
  • Optical Type: Double beam
  • Atomizer: Flame atomizer
  • Monochromator: Czerny-Turner type, focal length at 350mm
  • Wavelength Range: 190 to 900 nm
  • Wavelength Accuracy: ±0.15nm

$ 23000 / Each of 1

Atomic Absorption Spectrophotometer LMAAS-A104
  • Optical Type: Single beam
  • Atomizer: Flame atomizer
  • Monochromator: Czerny-Turner type, focal length at 350mm
  • Wavelength Range: 190 to 900 nm
  • Wavelength Accuracy: ±0.3nm

$ 18300 / Each of 1

Frequently Asked Questions

1 What is an Atomic Absorption Spectrophotometer?

An Atomic Absorption Spectrophotometer is an apparatus designed to measure the concentration of elements by detecting the absorption of optical radiation (light) by free atoms in the gaseous state.

2 How does Atomic Absorption Spectrophotometer work?

It works by measuring the absorption of light by vaporized atoms to determine the concentration of specific elements.

3 What elements can be detected using Atomic Absorption Spectrophotometer?

It can detect metals such as lead, copper, zinc, iron, calcium, and magnesium.

4 How is Atomic Absorption Spectrophotometer used in environmental analysis?

It is used in environmental analysis to detect trace metals like lead, mercury, and cadmium in water, soil, and air samples.

5 What is the role of Atomic Absorption Spectrophotometer in food safety testing?

It plays a vital role in food safety testing by measuring toxic metal residues such as arsenic and lead in food products.

6 Can Atomic Absorption Spectrophotometer be used in pharmaceutical industry?

In pharmaceutical industry, it is used to ensure raw materials and finished products meet safety standards by analyzing metal content.

7 Can Atomic Absorption Spectrophotometer be used in mining applications?

It is used in mining to analyze ore samples for valuable metals like gold, silver, and copper.

8 How is Atomic Absorption Spectrophotometer used in agriculture?

It is used in agriculture to monitor nutrient levels and detect toxic metals in soil, water, and fertilizers.

9 Can Atomic Absorption Spectrophotometer be used in forensic science?

In forensic science, it is used to detect trace metals in evidence such as gunshot residues or poisoned tissues.

10 How does Atomic Absorption Spectrophotometer assist in quality control in manufacturing?

It assists in quality control by verifying metal content in materials used in electronics, automotive, and metal finishing industries.