Get Quote

Contact us now to receive a detailed quotation.

Need quick help? Chat with us on WhatsApp:

WhatsApp QR Code

OR

Single Beam UV/Visible Spectrophotometer LMUS-B100

Single Beam UV/Visible Spectrophotometer LMUS-B100 offers 2nm bandwidth for high spectral resolution. Features wide wavelength range from 190 to 1100 nm. Designed with single-beam optical system with 1200 lines/mm grating for consistent light distribution. Built with auto-wavelength setting and multiple measurement modes, it supports versatile sample testing. Our Spectrophotometer incorporates silicon photodiode detector, deuterium and tungsten light sources, and user-friendly touchscreen interface.

Catalog Send Mail Whatsapp

Specifications

Wavelength 190 nm to 1100 nm
Spectral Bandwidth 2 nm
Optical System Single Beam, Grating 1200 lines/mm
Wavelength Accuracy ±0.1nm at 656.1nm, ±0.3nm at other wavelengths
Wavelength Repeatability Less than or equal to 0.1 nm
Wavelength Setting Auto
Photometric Range 0 to 200%T, –0.3 to 3A, 0 t0 9999C
Photometric Accuracy ±0.2%T(0 to 100%T), ±0.002A(0 to 0.5A), ±0.004A(0.5 to 1A)
Photometric Repeatability Less than or equal to 0.15%T (0 to 100%T), 0.001A(0 to 0.5A), 0.002A(0.5 to 1A)
Stray Light Less than or equal to 0.03%T at 220nm, 360nm
Stability ±0.0005A/h at 500nm
Baseline Flatness ±0.002A
Noise 0.0005A at 500nm
Detector Silicon Photodiode
Light Source Deuterium and Tungsten lamp
Work Mode T, A, C, E
Scanning Speed High, Medium, Low (Max. 3000nm/min)
Cuvette Holder 10mm manual 4-cell holder
Output USB drive, USB host, RS232
Display 10.1-inch Color Touch Screen
Power Supply AC 110 to 220V/50 to 60Hz
Package Dimension 810×660×390 mm
Gross Weight 27 kg

Features

Advanced photometric stability

Low stray light and noise

In-house massive memory

RS232 and USB port

Manual 4-cell cuvette holder

Energy-efficient functioning

Standard Accessories

Model No.

Accessory

LMUS-B100-G1

10mm Glass cuvette

LMUS-B100-Q1

10mm Quartz cuvette

LMUS-B100-P1

Power cord

LMUS-B100-PC1

PC Software

Optional Accessories

Model No.

Accessory

LMUS-B100-G2

5mm Glass Cuvette
LMUS-B100-G310mm Glass Cuvette
LMUS-B100-G420mm Glass Cuvette
LMUS-B100-G530mm Glass Cuvette
LMUS-B100-G650mm Glass Cuvette
LMUS-B100-G7100mm Glass Cuvette

LMUS-B100-Q2

5mm Quartz Cuvette
LMUS-B100-Q310mm Quartz Cuvette
LMUS-B100-Q420mm Quartz Cuvette
LMUS-B100-Q530mm Quartz Cuvette
LMUS-B100-Q650mm Quartz Cuvette
LMUS-B100-Q7100mm Quartz Cuvette

LMUS-B100-QM1

0.35/0.7/1.0/1.4/1.7ml Quartz Micro-Cuvette

LMUS-B100-QM2

50/100/200µl Quartz Micro-Cuvette

LMUS-B100-GM1

0.35/0.7/1.0/1.4/1.7ml Glass Micro-Cuvette

LMUS-B100-GM2

50/100/200µl Glass Micro-Cuvette

LMUS-B100-H1

10mm Manual 4-cell Holder

LMUS-B100-H2

50mm Manual 4-cell Holder

LMUS-B100-H3

100mm Manual 4-cell Holder

LMUS-B100-S1

10mm Single-hole Cell Holder

LMUS-B100-SH1

50mm Single-hole long-path cell Holder

LMUS-B100-SH2

100mm Single-hole long-path cell Holder

LMUS-B100-A1

Auto 8-cell/4-cell/5-cell Holder

LMUS-B100-F1

Film Holder

LMUS-B100-R1

Tube Rack

LMUS-B100-M1

Adjustable XY Micro Cell Holder

LMUS-B100-PS1

Peltier/Sipper System

LMUS-B100-I1

Integrating Sphere

LMUS-B100-T1

Tungsten Lamp

LMUS-B100-D1

Deuterium Lamp

LMUS-B100-X1

Xenon Lamp

LMUS-B100-TP1

Thermal Printer 

LMUS-B100-TP2

Built-in Thermal Printer

LMUS-B100-PC2

PC software

LMUS-B100-CF1

21 CFR software

Applications

Single Beam UV/Visible Spectrophotometer LMUS-B100 is employed in research, clinical, industrial, and educational laboratories for photometric measurement, quantitative analysis, kinetics, spectrum scan, DNA/protein test, and multi-wavelength test.

Similar Products

Single Beam UV/Visible Spectrophotometer LMUS-A303

  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ± 0.5 nm
  • Wavelength Repeatability: ≤ 0.2 nm

Single Beam UV/Visible Spectrophotometer LMUS-B102

  • Wavelength: 190 nm to 1100 nm
  • Spectral Bandwidth: 0.5 / 1 / 2 / 4 / 5 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ± 0.1nm
  • Wavelength Repeatability: Less than or equal to 0.1nm

Single Beam UV/Visible Spectrophotometer LMUS-A307

  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: 2 nm
  • Wavelength Repeatability: 1 nm
Single Beam UV/Visible Spectrophotometer LMUS-B101
  • Wavelength: 190 nm to 1100 nm
  • Spectral Bandwidth: 1 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ±0.1nm at 656.1nm, ±0.3nm at other wavelengths
  • Wavelength Repeatability: Less than or equal to 0.1 nm
Single Beam UV/Visible Spectrophotometer LMUS-A301
  • Wavelength: 190 nm to 1100 nm
  • Spectral Bandwidth: 1.8 nm
  • Optical System: Single Beam, Blazed Holographic Grating 1200 lines/mm
  • Wavelength Accuracy: ±0.5nm
  • Wavelength Repeatability: Less than or equal to 0.2 nm

Single Beam UV/Visible Spectrophotometer LMUS-A311

  • Wavelength Range: 190 nm to 1100 nm
  • Spectral Bandwidth: 0.5 nm, 1 nm, 2 nm, 4 nm, 5 nm
  • Diffraction Grating: 1200 lines/mm
  • Wavelength Accuracy: 0.3 nm
  • Wavelength Repeatability: 0.1 nm

Single Beam UV/Visible Spectrophotometer LMUS-A202

  • Wavelength: 190 nm to 1020 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ±2nm
  • Wavelength Repeatability: Less than or equal to 1 nm

Single Beam UV/Visible Spectrophotometer LMUS-A200

  • Wavelength: 195 nm to 1020 nm
  • Spectral Bandwidth: 5 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ± 2 nm
  • Wavelength Repeatability: 1 nm
Single Beam UV/Visible Spectrophotometer LMUS-A203
  • Wavelength: 190 nm to 1000 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: 1nm
  • Wavelength Repeatability: Less than or equal to 0.5 nm
Single Beam UV/Visible Spectrophotometer LMUS-A103
  • Wavelength: 190 nm to 1100 nm
  • Spectral Bandwidth: 0.1, 0.2, 0.5, 1, 2, 4, 5 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ±0.1nm at 656.1nm, ±0.3nm at other wavelengths
  • Wavelength Repeatability: Less than or equal to 0.1 nm

Single Beam UV/Visible Spectrophotometer LMUS-A310

  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 4 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: 2 nm
  • Wavelength Repeatability: 1nm

Single Beam UV/Visible Spectrophotometer LMUS-A308

  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 4 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ± 1 nm
  • Wavelength Repeatability: ≤ 0.3 nm

Single Beam UV/Visible Spectrophotometer LMUS-A306

  • Wavelength: 190 nm – 1100 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: 1 nm
  • Wavelength Repeatability: ≤ 0.2 nm
Single Beam UV/Visible Spectrophotometer LMUS-A204
  • Wavelength: 190 nm to 1000 nm
  • Spectral Bandwidth: 4 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: 1nm
  • Wavelength Repeatability: Less than or equal to 0.5 nm
Single Beam UV-Visible Spectrophotometer LMUS-B200
  • Wavelength Range: 190 to 1000 nm
  • Bandwidth: 2nm
  • Optical System: Single beam, grating 1200 lines/mm
  • Detector: Silicon Photodiode
  • Light Source: W Lamp and D2 Lamp

Frequently Asked Questions

1 What is a Single Beam UV/Visible Spectrophotometer?

A Single Beam UV/Visible Spectrophotometer is an apparatus designed to measure the absorbance or transmittance of a sample at specific wavelengths in the ultraviolet and visible light spectrum.

2 How does Single Beam UV/Visible Spectrophotometer work?

It works by passing a beam of light through a sample and comparing the intensity of light before and after it passes through the sample to determine absorbance.

3 How is Single Beam UV/Visible Spectrophotometer used in pharmaceutical analysis?

In pharmaceutical analysis, it is used to determine drug concentrations, monitor compound purity, and perform dissolution and stability studies.

4 How does Single Beam UV/Visible Spectrophotometer help in water quality testing?

It helps in water quality testing by detecting contaminants like nitrates, phosphates, and heavy metals through colorimetric or direct UV absorbance methods.

5 What role does Single Beam UV/Visible Spectrophotometer play in chemical kinetics studies?

It monitors the change in absorbance over time to study reaction rates and mechanisms in chemical kinetics.

6 How does Single Beam UV/Visible Spectrophotometer assist in environmental monitoring?

It is useful in environmental monitoring for analyzing pollutants in air, water, and soil samples through absorbance-based methods.

7 How is Single Beam UV/Visible Spectrophotometer used in clinical diagnostics?

It is used in clinical diagnostics to analyze blood, urine, and serum samples for biochemical markers such as glucose, cholesterol, and enzyme activity.

8 How can Single Beam UV/Visible Spectrophotometer be used for quality control in manufacturing?

It helps in quality control by ensuring consistent color, concentration, and purity of raw materials and finished products.

9 What role does Single Beam UV/Visible Spectrophotometer play in agricultural research?

In agricultural research, it is used to analyze soil nutrients, pesticide residues, and plant pigments like chlorophyll.

10 Is Single Beam UV/Visible Spectrophotometer used in forensic science?

It is used in forensic science to analyze substances such as drugs, inks, and stains by measuring their unique absorbance spectra.