Get Quote

Contact us now to receive a detailed quotation.

Need quick help? Chat with us on WhatsApp:

WhatsApp QR Code

OR

Single Beam UV/Visible Spectrophotometer LMUS-A308

Catalog Send Mail Whatsapp

Specifications

Wavelength 190 nm – 1100 nm
Spectral Bandwidth 4 nm
Optical System Single Beam, Grating 1200 lines/mm
Wavelength Accuracy ± 1 nm
Wavelength Repeatability ≤ 0.3 nm
Wavelength Setting Automatic
Photometric Range 0 – 200 % T, - 0.3 ~ 3 A, 0 – 9999 C
Photometric Setting ± 0.003 A (0 ~ 0.5 A), ± 0.005 A (0.5 ~ 1 A), ± 0.5 % T (0 ~ 100 % T)
Photometric Repeatability ≤ 0.002 A (0 ~ 0.5 A), ≤ 0.003 A (0.5 ~ 1 A), ≤ 0.3 % T (0 ~ 100 % T)
Detector Silicon Photodiode
Light Source Tungsten Lamp and Deuterium Lamp
Stray Light ≤ 0.2 %T (220/360 nm)
Stability ±0.002 A/h; 500 nm
Data Output Port USB / RS232 Port
Noise ≤ 0.2 % T/3 min (250/500 nm, 0 % T); ≤ 0.5 % T/3 min (250/500 nm, 100 % T)
Baseline Flatness ± 0.004 A
PC Software Optical PC Scanning Software
Sample Compartment Accommodates 5 – 100 mm Path-length cuvette
Display Graphic LCD (128 x 64 Dots)
Keypad 11-key Alphanumeric Membrane Keypad
Power Supply AC 90 - 250 V, 50 / 60 Hz
Dimension 413 x 318 x 195 mm
Net Weight 16 Kg

Pricing

Product Price Unit Action
Single Beam UV/Visible Spectrophotometer LMUS-A308 $ 4050 Pack of 1

Features

Wavelength range: 190 nm – 1100 nm Automatic wavelength and blank setting Spectral bandwidth: 4 nm Replaceable Pre-aligned lamps (Tungsten and Deuterium) USB port available Low noise and low stray light Optical PC scanning software (Optional)

Optional Accessories

Model NoSpecificationImage
A011 or 4-Cell Holder (5 ~ 100 nm Cuvette) 
A021 or 4-Cell Water-jacketed Cell Holder 
A03All kinds of Glass and Quartz cuvettes 
A04Micro cell Holder and Micro Cuvette 
A05Auto 5, 8 – Cell Holder (10 nm Cuvette) 
A06Auto 4,6 – Cell Holder (5 ~ 100 nm Cuvette) 
A07Thin Solid and Film holder 
A08Test tube Holder 
A09Tungsten lamp and Deuterium lamp 
A10Peltier and Sipper system 
A11Mini Thermal Printer 
A12Reflectance Measurement Attachment 
A13Integrating Sphere Accessory 

Similar Products

Single Beam UV/Visible Spectrophotometer LMUS-A301

  • Wavelength: 190 nm to 1100 nm
  • Spectral Bandwidth: 1.8 nm
  • Optical System: Single Beam, Blazed Holographic Grating 1200 lines/mm
  • Wavelength Accuracy: ±0.5nm
  • Wavelength Repeatability: Less than or equal to 0.2 nm

$ 3475 / Each of 1

Single Beam UV/Visible Spectrophotometer LMUS-A102

  • Wavelength: 190 nm to 1100 nm
  • Spectral Bandwidth: 1 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ±0.1nm at 656.1nm, ±0.3nm at other wavelengths
  • Wavelength Repeatability: Less than or equal to 0.1 nm

$ 4137.5 / Each of 1

Single Beam UV/Visible Spectrophotometer LMUS-B100

  • Wavelength: 190 nm to 1100 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ±0.1nm at 656.1nm, ±0.3nm at other wavelengths
  • Wavelength Repeatability: Less than or equal to 0.1 nm

$ 3762.5 / Each of 1

Single Beam UV/Visible Spectrophotometer LMUS-C101
  • Wavelength: 190 nm to 1100 nm
  • Spectral Bandwidth: 1 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ±0.3nm
  • Wavelength Repeatability: Less than or equal to 0.1 nm

$ 7225 / Each of 1

Single Beam UV/Visible Spectrophotometer LMUS-A203
  • Wavelength: 190 nm to 1000 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: 1nm
  • Wavelength Repeatability: Less than or equal to 0.5 nm

$ 2562.5 / Each of 1

Single Beam UV/Visible Spectrophotometer LMUS-C103

  • Wavelength: 190 nm to 1100 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ±0.1nm at 656.1nm, ±0.3nm at other wavelengths
  • Wavelength Repeatability: Less than or equal to 0.1 nm

$ 3712.5 / Each of 1

Single Beam UV/Visible Spectrophotometer LMUS-A103

  • Wavelength: 190 nm to 1100 nm
  • Spectral Bandwidth: 0.1, 0.2, 0.5, 1, 2, 4, 5 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ±0.1nm at 656.1nm, ±0.3nm at other wavelengths
  • Wavelength Repeatability: Less than or equal to 0.1 nm

$ 5450 / Each of 1

Single Beam UV/Visible Spectrophotometer LMUS-A101

  • Wavelength: 190 nm to 1100 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ±0.1nm at 656.1nm, ±0.3nm at other wavelengths
  • Wavelength Repeatability: Less than or equal to 0.1 nm

$ 4012.5 / Each of 1

Single Beam UV/Visible Spectrophotometer LMUS-C104
  • Wavelength: 190 nm to 1100 nm
  • Spectral Bandwidth: 1 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ±0.1nm at 656.1nm, ±0.3nm at other wavelengths
  • Wavelength Repeatability: Less than or equal to 0.1 nm

$ 3837.5 / Each of 1

Single Beam UV-Visible Spectrophotometer LMUS-B200
  • Wavelength Range: 190 to 1000 nm
  • Bandwidth: 2nm
  • Optical System: Single beam, grating 1200 lines/mm
  • Detector: Silicon Photodiode
  • Light Source: W Lamp and D2 Lamp

$ 2577.5 / Each of 1

Single Beam UV/Visible Spectrophotometer LMUS-B101

  • Wavelength: 190 nm to 1100 nm
  • Spectral Bandwidth: 1 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ±0.1nm at 656.1nm, ±0.3nm at other wavelengths
  • Wavelength Repeatability: Less than or equal to 0.1 nm

$ 4137.5 / Each of 1

Single Beam UV/Visible Spectrophotometer LMUS-A100

  • Wavelength: 190 nm to 1100 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ±0.1 at 656.1nm, ±0.3nm at other wavelengths
  • Wavelength Repeatability: Less than or equal to 0.1 nm

$ 3150 / Each of 1

Single Beam UV/Visible Spectrophotometer LMUS-C100

  • Wavelength: 190 nm to 1100 nm
  • Spectral Bandwidth: 2 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ±0.3nm
  • Wavelength Repeatability: Less than or equal to 0.1 nm

$ 6662.5 / Each of 1

Single Beam UV/Visible Spectrophotometer LMUS-C105
  • Wavelength: 190 nm to 1100 nm
  • Spectral Bandwidth: 0.5/1/2/4/5 nm
  • Optical System: Single Beam, Grating 1200 lines/mm
  • Wavelength Accuracy: ±0.1nm at 656.1nm, ±0.3nm at other wavelengths
  • Wavelength Repeatability: Less than or equal to 0.1 nm

$ 5175 / Each of 1

Single Beam UV/Visible Spectrophotometer LMUS-A300
  • Wavelength Range: 190 nm to 1100 nm
  • Spectral Bandwidth: 1 nm
  • Wavelength Accuracy: ±0.5 nm
  • Wavelength Repeatability: 0.2 nm
  • Photometric Range: 0 to 200%T, -0.3 A to 3 A

$ 3462.5 / Each of 1

Frequently Asked Questions

1 What is a Single Beam UV/Visible Spectrophotometer?

A Single Beam UV/Visible Spectrophotometer is an apparatus designed to measure the absorbance or transmittance of a sample at specific wavelengths in the ultraviolet and visible light spectrum.

2 How does Single Beam UV/Visible Spectrophotometer work?

It works by passing a beam of light through a sample and comparing the intensity of light before and after it passes through the sample to determine absorbance.

3 How is Single Beam UV/Visible Spectrophotometer used in pharmaceutical analysis?

In pharmaceutical analysis, it is used to determine drug concentrations, monitor compound purity, and perform dissolution and stability studies.

4 How does Single Beam UV/Visible Spectrophotometer help in water quality testing?

It helps in water quality testing by detecting contaminants like nitrates, phosphates, and heavy metals through colorimetric or direct UV absorbance methods.

5 What role does Single Beam UV/Visible Spectrophotometer play in chemical kinetics studies?

It monitors the change in absorbance over time to study reaction rates and mechanisms in chemical kinetics.

6 How does Single Beam UV/Visible Spectrophotometer assist in environmental monitoring?

It is useful in environmental monitoring for analyzing pollutants in air, water, and soil samples through absorbance-based methods.

7 How is Single Beam UV/Visible Spectrophotometer used in clinical diagnostics?

It is used in clinical diagnostics to analyze blood, urine, and serum samples for biochemical markers such as glucose, cholesterol, and enzyme activity.

8 How can Single Beam UV/Visible Spectrophotometer be used for quality control in manufacturing?

It helps in quality control by ensuring consistent color, concentration, and purity of raw materials and finished products.

9 What role does Single Beam UV/Visible Spectrophotometer play in agricultural research?

In agricultural research, it is used to analyze soil nutrients, pesticide residues, and plant pigments like chlorophyll.

10 Is Single Beam UV/Visible Spectrophotometer used in forensic science?

It is used in forensic science to analyze substances such as drugs, inks, and stains by measuring their unique absorbance spectra.