Get Quote

Contact us now to receive a detailed quotation.

Need quick help? Chat with us on WhatsApp:

WhatsApp QR Code

OR

Re-Circulating Chiller LMRCC-A102

Re-Circulating Chiller LMRCC-A102 has temperature range of -25°C to 30°C. It has digital display and user-friendly controls. Equipped with high-performance compressor and efficient cooling system. Integrated with 15L tank capacity for continuous operation. Our Chiller is ideal for laboratories and industrial cooling settings.

Catalog Manual Send Mail Whatsapp

Specifications

Volume 15L
Temperature Range -25℃ to 30℃
Temperature Control Accuracy ±0.5℃
Temperature Control And Display ASET multi-function control, LED
Pump Type Ultra-high temperature shielded pump
Flow Rate 20L/min
Pressure 1.2 bar
Compressor Cooling Water-cooling
Circulation Type Closed circulation
Temperature Controller PID 100 adaptive controller
Safety Protection Temperature probe abnormal alarm, multi-point temperature monitoring, overheating alarm, leakage protector, high-temperature system flat pressure protection, liquid level indication
Power Consumption 2.4KW
Power Supply 1PH AC 110V/220V/50 to 60Hz
Dimension 430×650×875 mm
Packaging Dimension 530×760×1060 mm
Net Weight 110 Kg
Gross Weight 130 Kg

Pricing

Product Price Unit Action
Re-Circulating Chiller LMRCC-A102 $ 3150 Each of 1

Features

High-efficiency heat exchanger 

45 segments per program 

7-inch touch screen 

Multiple interface options 

USB data storage 

Self-diagnostic function 

Standard Accessories

Accessory

Quantity

Unit

Stainless steel chassis

1

Piece

Compressor 

1

Piece

Plate heat exchanger 

1

Piece

Pump

1

Piece

Power Cord

1

Piece

Optional Accessories

Model No.

Accessory

Unit

Quantity

LMRCC-A102-H1

Heat-conducting oil metal hose

Each

1

LMRCC-A102-S1

Shell material 

Each

1

Applications

Re-Circulating Chiller LMRCC-A102 is ideal for laboratories, industrial cooling, and chemical process temperature control. It ensures stable cooling for research, manufacturing, and medical settings.

Similar Products

Recirculating Chiller LMRCC-B102

  • Volume: 10 L
  • Working Temperature Range: -20 to 25℃
  • Temperature Stability: ±2°C
  • Flow Rate: 20 L/min
  • Cooling Method: Air cooling

$ 3200 / Each of 1

Recirculating Chiller LMRCC-C101

  • Temperature Range: -80 to -40℃
  • Reservoir Capacity: 10L
  • Flow Rate: 30L/min
  • Pressure: 1bar
  • Cooling Method: Air cooling

$ 19575 / Each of 1

Recirculating Chiller LMRCC-B103

  • Volume: 10 L
  • Working Temperature Range: -30 to 5℃
  • Temperature Stability: ±2°C
  • Flow Rate: 20 L/min
  • Cooling Method: Air cooling

$ 3425 / Each of 1

Recirculating Chiller LMRCC-A100
  • Volume: 3 L
  • Compressor Brand: Embraco Aspera(Original in Brazil)
  • Temperature Control: LCD Digital Display, ± 2°, PT100
  • Meter Adjustment Range: ± 50
  • Safety protection: Delay Time, Overcurrent, Overheating

$ 2112.5 / Pack of 1

Re-Circulating Chiller LMRCC-A101
  • Volume: 4.8 Liters
  • Temperature Range: -20°C to -30°C
  • Temperature Control System: On-off control
  • Temperature Indicator: Digital display
  • Environment Temperature Use Range: 5°C to 35°C

$ 3362.5 / Each of 1

Recirculating Chiller LMRCC-B106

  • Volume: 40 L
  • Working Temperature Range: -30 to 5℃
  • Temperature Stability: ±2°C
  • Flow Rate: 30 L/min
  • Cooling Method: Air cooling

$ 8037.5 / Each of 1

Recirculating Chiller LMRCC-B105

  • Volume: 30 L
  • Working Temperature Range: -30 to 5℃
  • Temperature Stability: ±2°C
  • Flow Rate: 20 L/min
  • Cooling Method: Air cooling

$ 4956.25 / Each of 1

Recirculating Chiller LMRCC-B104

  • Volume: 17 L
  • Working Temperature Range: -30 to 5℃
  • Temperature Stability: ±2°C
  • Flow Rate: 20 L/min
  • Cooling Method: Air cooling

$ 3893.75 / Each of 1

Recirculating Chiller LMRCC-C100
  • Temperature Range: -80 to -40℃
  • Reservoir Capacity: 10L
  • Flow Rate: 30L/min
  • Pressure: 1bar
  • Cooling Method: Air cooling

$ 15825 / Each of 1

Recirculating Chiller LMRCC-C102
  • Temperature Range: -80 to -40℃
  • Reservoir Capacity: 24L
  • Flow Rate: 30L/min
  • Pressure: 1bar
  • Cooling Method: Air cooling

$ 29412.5 / Each of 1

Recirculating Chiller LMRCC-B100

  • Volume: 4 L
  • Working Temperature Range: -20℃ to RT
  • Flow Rate: 8 to 16L/min
  • Pressure: Less than or equal to 0.1Mpa
  • Pump Lift Range: 1.5 to 2.7m

$ 2000 / Each of 1

Recirculating Chiller LMRCC-B101

  • Volume: 3 L
  • Working Temperature Range: -15 to 25℃
  • Temperature Stability: ±2°C
  • Flow Rate: 17 L/min
  • Cooling Method: Air cooling

$ 2575 / Each of 1

Frequently Asked Questions

1 What is a Re-circulating Chiller?

A Re-circulating Chiller is an apparatus designed to maintain a stable temperature by continuously circulating a coolant through a process or equipment, removing heat and re-cooling the fluid for reuse.

2 How does a Re-circulating Chiller work?

It works by circulating coolant through a closed loop to absorb heat and then cooling the fluid for reuse.

3 What kind of maintenance does Re-circulating Chiller require?

Regular maintenance includes checking coolant levels, cleaning filters, and inspecting for leaks.

4 How does Re-circulating Chiller benefit laboratory applications?

It maintains precise temperature for equipment like rotary evaporators and spectrometers, ensuring accurate results and preventing overheating.

5 Can Re-circulating Chiller be used for cooling industrial lasers?

It is commonly used to cool industrial lasers by removing excess heat, maintaining optimal performance, and preventing damage from overheating.

6 How does Re-circulating Chiller assist in biotech and pharmaceutical research?

It provide temperature control for experiments and equipment, preserving the integrity of sensitive samples and ensuring consistent results in biotech and pharmaceutical research.

7 Can Re-circulating Chiller be used in food and beverage production?

It is used in food and beverage production to cool processing equipment, such as tanks or mixers, ensuring safety and quality in temperature-sensitive process.

8 Can Re-circulating Chiller be used in environmental chambers?

It is used to help maintain controlled temperature and humidity in environmental testing chambers for electronics, materials, or biological samples.

9 How does Re-circulating Chiller assist in aerospace component testing?

It provide precise thermal control for high-stress tests on avionics, sensors, or fuel systems, ensuring reliability under variable flight conditions.

10 How does Re-circulating Chiller support forensic or pathology labs?

It cools microtomes, tissue processors and chemical baths, helping preserve tissue integrity and sample quality for analysis and diagnostics.