Single Automated Gram Stainer

Single Automated Gram Stainer units run Gram staining on a batch of slides without manual dipping. Spray staining applies reagent to each slide, so little reagent is wasted. Reagent capacity is 1 ml per slide. One model holds 12 or 24 slides in a vertical rack. The other holds 1 to 16 slides in a horizontal tray. Crystal violet and iodine are listed reagents. Brushless DC motors drive the unit quietly. Quiet, low-power motors suit a busy microbiology bench. Electromagnetic locks control the lid. Both models stain Gram only, so one unit handles one stain type. Microbiology and research labs use these stainers to stain bacterial smears for Gram reading.

 Compare

Single Automated Gram Stainer LMSGS-A100

  • Staining Type: Gram Staining
  • Slide Capacity: 12 or 24
  • Slide Installation: Vertical
  • Staining Reagents: Crystal Violet, Iodine Solution, Acetone Fuchsin
  • Reagents Capacity: 1 ml/Slide

$ 14150 / Each of 1

 Compare

Single Automated Gram Stainer LMSGS-A101

  • Staining Type: Gram Staining
  • Slide Capacity: 1 to 16
  • Slide Installation: Horizontal
  • Staining Reagents: Crystal Violet, Iodine Solution, Acetone Fuchsin
  • Reagents Capacity: 1 ml/Slide

$ 14150 / Each of 1

Frequently Asked Questions

1 What is a Single Automated Gram Stainer?

A Single Automated Gram Stainer is a laboratory apparatus engineered to automate the process of Gram staining that differentiates Gram-positive & Gram-negative bacteria.

2 How does Single Automated Gram Stainer work?

It works by automating the key steps in Gram staining process that utilizes programmed sequence to apply each reagent & controls the timing of each step.

3 Can Single Automated Gram Stainer handle multiple samples?

It can handle multiple samples & provide consistent results.

4 Is Single Automated Gram Stainer compatible with all bacterial samples?

Gram staining is suitable for most of the bacterial samples but some microorganisms may require additional modifications.

5 What kind of maintenance does the Single Automated Gram Stainer require?

Regular maintenance includes Cleaning of staining chamber, replacement of pumps or trays & proper calibration of the apparatus.

6 How does the Single Automated Gram Stainer prevent cross-contamination?

It is designed with separate compartments that is dedicated to each sample thereby minimizing the risk of cross-contamination.