Refrigerated and Heating Circulators LMRH-A102 are temperature-controlled circulating water baths with a pump flow rate of 10L/min with high heating/cooling capacities. Enhanced with PID temperature control system for maintaining desired temperatures. Intended with a rust-free stainless chamber that has a filling capacity of 6 L. Featuring with capability to protect the equipment by providing high and low-temperature warnings and making it an eco-friendly device.

Catalog Send Mail Whatsapp

Specifications

Pump Flow Rate 10 L/min
Temperature Range -20℃ to 100℃
Stability ±0.03℃
Temperature Sensor PT 100
Pump Capacity Pressure 0.35 bar
Heater Consumption 2000 W
Cooling Consumption 250 W
Ambient Temperature - 20℃ -70℃
Bath Opening 160 × 160 mm
Temperature Control PID
Bath Dimension 320 × 180 × 150 mm
Refrigerant R134a
Filling Capacity 6 L
Voltage AC 220 V ± % ,50 Hz
Outer Dimension 400 × 250 × 650 mm
Net Weight 42 kg

Features

Built with a circulatory pump for circulating the temperature-controlled fluids
Improved stainless steel construction ensures hygienic cleaning
Designed with high-resolution digitally controlled LCD display
Safety measures are included in these circulators to guarantee secure operations
Incorporated with Refrigerant R134a which makes the circulator eco-friendly
Equipped with a high-quality compressor and a mute pump
Include PT100 temperature sensor to maintain temperature stability and accuracy
The water reservoir is a robust water tank that is rust-proof
Easily adjustable with low maintenance requirements

Applications

It is widely used in research institutes and laboratories, for incubating reagents essential for molecular biology and tissue culture experiments.

Similar Products

Refrigerated and Heating Circulator LMRH-B109

  • Working Temperature Range: -30 to 200℃
  • Fluid Filling Volume: 12L
  • Flow Rate: 45L/min
  • Pressure: 1.4 bar
  • Cooling Method: Water cooling

Refrigerated And Heating Circulators LMRH-A103

  • Pump Flow Rate: 10 L/min
  • Temperature Range: -20℃ to100℃
  • Stability: ±0.03℃
  • Temperature Sensor: PT 100
  • Pump Capacity Pressure: 0.35 bar

Refrigerated And Heating Circulators LMRH-A101

  • Pump Flow Rate: 10 L/min
  • Temperature Range: -5℃ to 100℃
  • Stability: ±0.03℃
  • Temperature Sensor: PT 100
  • Pump Capacity Pressure: 0.35 bar
Refrigerated And Heating Circulators LMRH-A100
  • Pump Flow Rate: 10 L/min
  • Temperature Range: -5℃ to 100℃
  • Stability: ±0.03℃
  • Temperature Sensor: PT 100
  • Pump Capacity Pressure: 0.35 bar
Refrigerated and Heating Circulator LMRH-B101
  • Working Temperature Range: -30 to 200℃
  • Fluid Filling Volume: 3L
  • Flow Rate: 30L/min
  • Pressure: 1.0bar
  • Cooling Method: Water cooling

Refrigerated and Heating Circulator LMRH-B103

  • Working Temperature Range: -40 to 200℃
  • Fluid Filling Volume: 4L
  • Flow Rate: 30L/min
  • Pressure: 1.0bar
  • Cooling Method: Water cooling

Refrigerated And Heating Circulators LMRH-A104

  • Temperature Range: -20°C to 35°C
  • Maximum Flow: 40 L/min
  • Rated Flow: 15 L/min at 2.4 bar
  • Max Pressure: 2.5 bar
  • Temperature Stability: ±0.2℃

Refrigerated and Heating Circulator LMRH-B105

  • Working Temperature Range: -30 to 200℃
  • Fluid Filling Volume: 8L
  • Flow Rate: 30L/min
  • Pressure: 1.0bar
  • Cooling Method: Water cooling
Refrigerated and Heating Circulator LMRH-B106
  • Working Temperature Range: -40 to 200℃
  • Fluid Filling Volume: 10 L
  • Flow Rate: 30L/min
  • Pressure: 1.0bar
  • Cooling Method: Air cooling
Refrigerated and Heating Circulator LMRH-B108
  • Working Temperature Range: -30 to 200℃
  • Fluid Filling Volume: 12 L
  • Flow Rate: 45L/min
  • Pressure: 1.4 bar
  • Cooling Method: Air cooling

Refrigerated and Heating Circulator LMRH-B102

  • Working Temperature Range: -40 to 200℃
  • Fluid Filling Volume: 4 L
  • Flow Rate: 30L/min
  • Pressure: 1.0bar
  • Cooling Method: Air cooling

Refrigerated and Heating Circulator LMRH-B100

  • Working Temperature Range: -30 to 200℃
  • Fluid Filling Volume: 3L
  • Flow Rate: 30L/min
  • Pressure: 1.0bar
  • Cooling Method: Air cooling

Refrigerated and Heating Circulator LMRH-B104

  • Working Temperature Range: -30 to 200℃
  • Fluid Filling Volume: 8 L
  • Flow Rate: 30L/min
  • Pressure: 1.0bar
  • Cooling Method: Air cooling
Refrigerated and Heating Circulator LMRH-B107
  • Working Temperature Range: -40 to 200℃
  • Fluid Filling Volume: 10L
  • Flow Rate: 30L/min
  • Pressure: 1.0bar
  • Cooling Method: Water cooling

Frequently Asked Questions

1 What safety features are included in Refrigerated and Heating Circulator?

It includes over-temperature protection, low-liquid level alarms, pressure sensors and automatic shut-off mechanisms for safe operation.

2 Can Refrigerated and Heating Circulator be used with rotary evaporators?

It is commonly used with rotary evaporators to control the temperature of the condenser coil, enhancing solvent recovery efficiency by ensuring precise cooling.

3 Why is Refrigerated and Heating Circulator important in pharmaceutical testing?

It is used to simulate and control specific storage or reaction conditions, supporting drug stability testing, crystallization studies and bioassay development.

4 What is the role of Refrigerated and Heating Circulator in biotechnology?

It is used to maintain specific temperatures for cell cultures, enzyme reactions and DNA amplification processes in biotechnology labs.

5 Can Refrigerated and Heating Circulator be used in petroleum and petrochemical labs?

It is used in viscosity tests, flash point studies and distillation experiments where stable thermal conditions are crucial for reliable data.

6 Can Refrigerated and Heating Circulator be used for crystallization control?

It is used in temperature-sensitive crystallization processes to control nucleation and crystal growth conditions.

7 Can Refrigerated and Heating Circulator be used in photobioreactor systems?

It is used to maintain optimal temperature in photobioreactor systems used for algae cultivation, ensuring stable growth conditions for biofuel applications.

8 What is a Refrigerated and Heating Circulator?

A Refrigerated and Heating Circulator is an apparatus designed to precisely control fluid temperature by both cooling and heating for laboratory or industrial applications.

9 How does a Refrigerated and Heating Circulator work?

It works by circulating temperature-controlled fluid through an external system using built-in heating and cooling elements.

10 Can Refrigerated and Heating Circulator be used with closed-loop systems?

It is engineered for both open and closed-loop systems, providing stable and efficient heat transfer.