Refrigerated and Heating Circulator LMRH-B102 comes with temperature range of -40 to 200℃. Equipped with dynamic system, it provides cold and heat sources for diverse industrial requirements. It features program control of 1 to 120 segments, supporting both fixed value and segmented processes. Incorporates protection against high pressure, leakage, compressor delays, overload, and phase sequence issues. Our Circulator is ideal for external thermal regulation in various settings.

Catalog Send Mail Whatsapp

Specifications

Working Temperature Range -40 to 200℃
Fluid Filling Volume 4 L
Flow Rate 30L/min
Pressure 1.0bar
Cooling Method Air cooling
Fluid Viscosity 30 mm²/s
Refrigerant R404A
Display 7-inch LCD screen
Date And Communication Interface USB, RS485, Pt100
Noise 65dB(A)
Protection Grade IP20
Ambient Temperature 5 to 35℃
Temperature Control Accuracy ±0.5℃
Display Resolution 0.01
Outer Circulation Interface Size R₂¾
Cooling Capacity -200℃-3kW, 100℃-3kW, 25℃-2.4kW, -10℃-1.4kW, -20℃-1.2kW, -30℃-0.45Kw, -40℃-0.25kW
Heating Power 3kW
Power Consumption 5.7kW
Power Supply 380V, 50Hz
Dimensions 640×860×1270 mm
Net Weight 205 Kg

Pricing

Product Price Unit Action
Refrigerated and Heating Circulator LMRH-B102 $ 12737.5 Each of 1

Features

Closed circulation

Liquid level monitoring

RS485 connectivity

USB data export

Touch screen display

Caster wheel 

Applications

Refrigerated and Heating Circulator LMRH-B102 is applied for external thermal control for reactors, testing systems, and processing equipment across biotechnology, pharmaceuticals, and food sectors, for pilot production, and fermentation.

Circulator with dynamic system
Circulator with dynamic system

Similar Products

Refrigerated and Heating Circulator LMRH-B101

  • Working Temperature Range: -30 to 200℃
  • Fluid Filling Volume: 3L
  • Flow Rate: 30L/min
  • Pressure: 1.0bar
  • Cooling Method: Water cooling

$ 13650 / Each of 1

Refrigerated and Heating Circulator LMRH-B105

  • Working Temperature Range: -30 to 200℃
  • Fluid Filling Volume: 8L
  • Flow Rate: 30L/min
  • Pressure: 1.0bar
  • Cooling Method: Water cooling

$ 17037.5 / Each of 1

Refrigerated And Heating Circulators LMRH-A102

  • Pump Flow Rate: 10 L/min
  • Temperature Range: -20℃ to 100℃
  • Stability: ±0.03℃
  • Temperature Sensor: PT 100
  • Pump Capacity Pressure: 0.35 bar

$ 3587.5 / Pack of 1

Refrigerated and Heating Circulator LMRH-B109
  • Working Temperature Range: -30 to 200℃
  • Fluid Filling Volume: 12L
  • Flow Rate: 45L/min
  • Pressure: 1.4 bar
  • Cooling Method: Water cooling

$ 25212.5 / Each of 1

Refrigerated And Heating Circulators LMRH-A103
  • Pump Flow Rate: 10 L/min
  • Temperature Range: -20℃ to100℃
  • Stability: ±0.03℃
  • Temperature Sensor: PT 100
  • Pump Capacity Pressure: 0.35 bar

$ 3150 / Pack of 1

Refrigerated And Heating Circulators LMRH-A101

  • Pump Flow Rate: 10 L/min
  • Temperature Range: -5℃ to 100℃
  • Stability: ±0.03℃
  • Temperature Sensor: PT 100
  • Pump Capacity Pressure: 0.35 bar

$ 3437.5 / Pack of 1

Refrigerated and Heating Circulator LMRH-B107

  • Working Temperature Range: -40 to 200℃
  • Fluid Filling Volume: 10L
  • Flow Rate: 30L/min
  • Pressure: 1.0bar
  • Cooling Method: Water cooling

$ 21400 / Each of 1

Refrigerated and Heating Circulator LMRH-B110

  • Working Temperature Range: -40 to 200℃
  • Fluid Filling Volume: 12 L
  • Flow Rate: 45L/min
  • Pressure: 1.4 bar
  • Cooling Method: Air cooling

$ 25362.5 / Each of 1

Refrigerated and Heating Circulator LMRH-B106
  • Working Temperature Range: -40 to 200℃
  • Fluid Filling Volume: 10 L
  • Flow Rate: 30L/min
  • Pressure: 1.0bar
  • Cooling Method: Air cooling

$ 17850 / Each of 1

Refrigerated and Heating Circulator LMRH-B104
  • Working Temperature Range: -30 to 200℃
  • Fluid Filling Volume: 8 L
  • Flow Rate: 30L/min
  • Pressure: 1.0bar
  • Cooling Method: Air cooling

$ 13487.5 / Each of 1

Refrigerated And Heating Circulators LMRH-A100

  • Pump Flow Rate: 6 L/min
  • Temperature Range: -5℃ to 100℃
  • Stability: ±0.03℃
  • Temperature Sensor: PT 100
  • Pump Capacity Pressure: 0.35 bar

$ 3575 / Pack of 1

Refrigerated and Heating Circulator LMRH-B108

  • Working Temperature Range: -30 to 200℃
  • Fluid Filling Volume: 12 L
  • Flow Rate: 45L/min
  • Pressure: 1.4 bar
  • Cooling Method: Air cooling

$ 21662.5 / Each of 1

Refrigerated and Heating Circulator LMRH-B100

  • Working Temperature Range: -30 to 200℃
  • Fluid Filling Volume: 3L
  • Flow Rate: 30L/min
  • Pressure: 1.0bar
  • Cooling Method: Air cooling

$ 10100 / Each of 1

Refrigerated And Heating Circulators LMRH-A104
  • Temperature Range: -20°C to 35°C
  • Maximum Flow: 40 L/min
  • Rated Flow: 15 L/min at 2.4 bar
  • Max Pressure: 2.5 bar
  • Temperature Stability: ±0.2℃

$ 4162.5 / Each of 1

Refrigerated and Heating Circulator LMRH-B103
  • Working Temperature Range: -40 to 200℃
  • Fluid Filling Volume: 4L
  • Flow Rate: 30L/min
  • Pressure: 1.0bar
  • Cooling Method: Water cooling

$ 16287.5 / Each of 1

Frequently Asked Questions

1 What safety features are included in Refrigerated and Heating Circulator?

It includes over-temperature protection, low-liquid level alarms, pressure sensors and automatic shut-off mechanisms for safe operation.

2 Can Refrigerated and Heating Circulator be used with rotary evaporators?

It is commonly used with rotary evaporators to control the temperature of the condenser coil, enhancing solvent recovery efficiency by ensuring precise cooling.

3 Why is Refrigerated and Heating Circulator important in pharmaceutical testing?

It is used to simulate and control specific storage or reaction conditions, supporting drug stability testing, crystallization studies and bioassay development.

4 What is the role of Refrigerated and Heating Circulator in biotechnology?

It is used to maintain specific temperatures for cell cultures, enzyme reactions and DNA amplification processes in biotechnology labs.

5 Can Refrigerated and Heating Circulator be used in petroleum and petrochemical labs?

It is used in viscosity tests, flash point studies and distillation experiments where stable thermal conditions are crucial for reliable data.

6 Can Refrigerated and Heating Circulator be used for crystallization control?

It is used in temperature-sensitive crystallization processes to control nucleation and crystal growth conditions.

7 Can Refrigerated and Heating Circulator be used in photobioreactor systems?

It is used to maintain optimal temperature in photobioreactor systems used for algae cultivation, ensuring stable growth conditions for biofuel applications.

8 What is a Refrigerated and Heating Circulator?

A Refrigerated and Heating Circulator is an apparatus designed to precisely control fluid temperature by both cooling and heating for laboratory or industrial applications.

9 How does a Refrigerated and Heating Circulator work?

It works by circulating temperature-controlled fluid through an external system using built-in heating and cooling elements.

10 Can Refrigerated and Heating Circulator be used with closed-loop systems?

It is engineered for both open and closed-loop systems, providing stable and efficient heat transfer.