Dual Block Thermal Cycler LMMB-E101 utilizes 8 Peltier heating units to heat up the sample with 4 variations in temperature. It has preprogrammed 11 PCR protocols saved in internal flash memory. The instrument work significantly faster using windows operations system and can monitor the operations via mobile connectivity. Movable heating lid can accommodate 96×0.2 ml. It can with stand up to ramping rate of 5 °C/s and temperature range of 0 to 100 °C. Installed with capability of analyzing maximum 100 cycles and can save 10000 PRC run data. The parameters update and file transfer updates through Wi-Fi, USB, printer can be seen on 8-inches LCD display
Specifications
| Capacity | 96×0.2 ml |
| Temperature Range | 0 to 100 °C |
| Maximum. Heating Rate | 5 °C/s |
| Maximum. Cooling Rate | 4 °C/s |
| Uniformity | ≤ ± 0.2 °C |
| Accuracy | ≤ ± 0.1 °C |
| Display Resolution | 0.1 °C |
| Temperature Control | Block\Tube |
| Ramping Rate Adjustable | 0.1 to 5 °C |
| Gradient Uniformity | NA |
| Gradient Accuracy | NA |
| Gradient Temperature. Range | NA |
| Gradient Spread | NA |
| Hot Lid Temperature | 30 to 110 °C |
| Hot Lid Height Adjustable | Step less Adjustable |
| No. Of Programs | 10000 +(USB FLASH) |
| Maximum. No. Of Step | 30 |
| Maximum. No. Of Cycle | 100 |
| Increment/Decrement Time | 1 Sec to 600 Sec |
| Increment/Decrement Temperature | 0.1 to 10.0 °C |
| Pause Function | Yes |
| Auto Data Protection | Yes |
| Holding | 4 °C |
| Yes | |
| LAN to computer | Yes |
| LCD | 8 inch, 800 x 600 pels, 260,000 colors |
| Interface | USB2.0 , LAN |
| Dimensions(L×W×H) | 390×270×255 mm |
| Weight | 9 kg |
| Power Consumption | 600 W |
| Power Supply | 85 to 264 V AC , 47 to 63 Hz |
Pricing
| Product | Price | Unit | Action |
|---|---|---|---|
| Dual Block Thermal Cycler LMMB-E101 | $ 3875 | Each of 1 |
Features
It has 8-inches LCD display which enables the user to change the commands
Uniform heating with 4 different temperature of the samples is achieved with 8 Peltier heating units with maximum 100 cycles
It is well built with anodizing technology with aluminum block treatment which makes the durable and corrosion resistant
Two different PCR programs can be assigned in 2 PCR blocks
Maximum. Heating Rate is 5 °C/s with temperature range of 0 to 100 °C
It has the capability to accommodate 96×0.2 ml or Double 48×0.2ml with moveable hot lid which can fit different sizes of tubes
It has the internal flash memory to store the 10000 files data for analysis
The connectivity between computer is via USB port and mini printer and can store the GLP data after every step to get reliable results
All the operations are controlled by a computer software system which instrument PCR protocols and also has in built 11 standard protocols
It has power of operation recovery option which helps in continuing the same command after a recovering from power cut
The user can access to his individual experimental data by setting a password and data management system
To satisfy the customers need it is installed with special feature like the user can add sample while the process is going on to encounter different variations
The user will be sent notifications via email about the process to alert when operation ends
Applications
Used in Gene expression analysis, Pathogen detection, DNA methylation analysis, Genotyping and gene scanning, miRNA research etc.
Similar Products
$ 4312.5 / Each of 1
$ 4312.5 / Each of 1
$ 4862.5 / Each of 1
$ 5012.5 / Pack of 1
$ 4312.5 / Each of 1
$ 4662.5 / Pack of 1
Frequently Asked Questions
1 What is a Dual Block Thermal Cycler LMMB-E101?
A Dual Block Thermal Cycler LMMB-E101 is a PCR machine that enables fast and precise DNA amplification with two independent blocks.
2 How does a Dual Block Thermal Cycler LMMB-E101 work?
A Dual Block Thermal Cycler LMMB-E101 operates by repeatedly heating and cooling samples to amplify DNA through PCR.
3 Can Dual Block Thermal Cycler LMMB-E101 be used for cloning experiments?
Dual Block Thermal Cycler LMMB-E101 amplifies DNA fragments required for cloning workflows.
4 Does Dual Block Thermal Cycler LMMB-E101 support pharmacogenomics testing?
Dual Block Thermal Cycler LMMB-E101 enables amplification of genes to study drug response variations in patients.
5 Is Dual Block Thermal Cycler LMMB-E101 suitable for hematological genetic disorder analysis?
Dual Block Thermal Cycler LMMB-E101 supports PCR amplification of genes involved in blood disorders like thalassemia and sickle cell anemia.
6 Can Dual Block Thermal Cycler LMMB-E101 assist in transplantation genetics?
Dual Block Thermal Cycler LMMB-E101 useful in HLA typing and monitoring donor-recipient compatibility.
7 Does Dual Block Thermal Cycler LMMB-E101 support research in plant genetics?
Dual Block Thermal Cycler LMMB-E101 enables DNA amplification for plant breeding and genetic modification studies.
8 Is Dual Block Thermal Cycler LMMB-E101 useful in forensic science?
Dual Block Thermal Cycler LMMB-E101 is used for DNA amplification in forensic sample analysis.
9 Can Dual Block Thermal Cycler LMMB-E101 be used in veterinary diagnostics?
Dual Block Thermal Cycler LMMB-E101 supports PCR testing for animal disease diagnosis and research.
10 What kind of maintenance does Dual Block Thermal Cycler LMMB-E101 require?
Routine maintenance involves regularly cleaning the unit, checking the lid and ventilation, updating the software, and annual calibration to ensure optimal performance.
11 What is a Multi-Block Thermal Cycler?
A Multi-Block Thermal Cycler is an apparatus designed to run multiple PCR reactions at different temperatures simultaneously, using separate blocks for precise thermal control.
12 How does Multi-Block Thermal Cycler enhance throughput in microbial detection assays?
It enhances microbial detection throughput by running different pathogen-specific assays simultaneously in separate blocks, saving time and resources.
13 Can Multi-Block Thermal Cycler be used in forensic DNA analysis?
It is used in forensic DNA analysis to optimize and validate various STR or mitochondrial DNA assays under different thermal conditions simultaneously.
14 How does Multi-Block Thermal Cycler benefit synthetic biology workflows?
It benefits synthetic biology workflows by allowing multiple gene assembly reactions, mutagenesis cycles, and amplification protocols to run simultaneously with customized parameters.
15 How does Multi-Block Thermal Cycler aid in vaccine development research?
It aids in vaccine development by supporting optimization of PCR-based gene amplification, cloning constructs, and multiplex detection assays in one system.
16 How can Multi-Block Thermal Cycler be used in microbiome research?
It is used in microbiome research to optimize primers and PCR conditions for multiple 16S rRNA regions or metagenomic markers in parallel.
17 How is Multi-Block Thermal Cycler beneficial in personalized medicine research?
It is beneficial in personalized medicine by allowing optimization of patient-specific PCR assays, including pharmacogenomic and companion diagnostic tests.
18 How does Multi-Block Thermal Cycler assist in biodegradation and environmental DNA studies?
It assists in biodegradation and eDNA studies by allowing testing of complex environmental samples with multiple primer sets targeting diverse microbial genes.
19 Is Multi-Block Thermal Cycler useful in rare disease gene detection protocols?
It is useful in rare disease detection by optimizing PCR conditions for hard-to-amplify or low-abundance target sequences often present in such studies.
20 Can Multi-Block Thermal Cycler aid in studying viral genome diversity?
It aid in studying viral genome diversity by enabling amplification of multiple genomic regions across varied primer and temperature sets in one run.