Get Quote

Contact us now to receive a detailed quotation.

Flame Photometer LMFM-A104

Flame Photometer LMFM-A104 has measuring range of 0.1 to 1000 ppm. It features digital display and automatic ignition system. Equipped with high-efficiency optical filter for stable readings. It supports simultaneous detection of sodium, potassium, barium, lithium, and calcium. Our Photometer is ideal for clinical, pharmaceutical, and environmental analysis.

Catalog Manual Send Mail Whatsapp

Specifications

Test Element K, Na, Ca, Li, Ba
Channel Quantity 5
Test Range K: 0.15 to 100 ppm, Na: 0.18 to 100 ppm, Li: 0.1 to 30 ppm, Ca: 0.1 to 1000 ppm, Ba: 0.1 to 300 ppm
Limit Of Detection K: less than or equal to 0.158 ppm, Na: less than or equal to 0.184 ppm, Li: less than or equal to 0.1032 ppm, Ca: less than or equal to 2 ppm, Ba: less than or equal to 6.028
Linear Error K: less than or equal to 0.195 ppm, Na: less than or equal to 0.69 ppm, Li: less than or equal to 0.1449 ppm, Ba: less than or equal to 9.402, Ca: less than or equal to 3 ppm
Response Time 8s
Sample Uptake Less than 6 mL/min
Stability 3%(15s), 15%(6 min)
Reproducibility 2%
Air Compressor External
Printer Optional built-in thermal printer
Communication USB
Fuel LPG
Power Supply AC 220V ±10%, 50Hz ±1Hz
Dimension 570 × 560 × 400 mm
Weight 18 Kg

Features

Stable readings

Fast flame analysis

Compact and lightweight design

Low maintenance

Optional Accessories

Software

Printer

Atomizer

Applications

Flame Photometer LMFM-A104 is employed in clinical diagnostics, pharmaceutical testing, and agricultural research. It ensures reliable sodium, potassium, lithium, calcium, and barium analysis in samples.

Similar Products

Flame Photometer LMFM-B100

  • Test Element: K, Na, Li, Ca, Ba
  • Channel Quantity: 5
  • Reading Range: Concentration: 0.000 to 999.9, Energy 0 to 65535
  • Test Range: K: 0 to 100 ppm, Na: 0 to 160 ppm, Li: 0 to 100 ppm, Ca: 0 to 1000 ppm, Ba: 0 to 3000ppm
  • Limit Of Detection: K: less than 0.004mmol/L, Na: less than 0.008mmol/L, Li: less than 0.015mmol/L, Ca: less than 0.050mmol/L, Ba: less than 0.044mmol/L

Flame Photometer LMFM-B104

  • Test Element: K, Na, Li
  • Channel Quantity: 3
  • Reading Range: Concentration: 0.000 to 999.9, Energy 0 to 65535
  • Test Range: K: 0 to 100 ppm, Na: 0 to 160 ppm, Li: 0 to 100 ppm
  • Limit Of Detection: K: less than 0.004mmol/L, Na: less than 0.008mmol/L, Li: less than 0.015mmol/L

Flame Photometer LMFM-B103

  • Test Element: K, Na, Ca
  • Channel Quantity: 3
  • Reading Range: Concentration: 0.000 to 999.9, Energy 0 to 65535
  • Test Range: K: 0 to 100 ppm, Na: 0 to 160 ppm, Ca: 0 to 1000 ppm
  • Limit Of Detection: K: less than 0.004mmol/L, Na: less than 0.008mmol/L, Ca: less than 0.050mmol/L
Flame Photometer LMFM-B101
  • Test Element: K, Na, Li, Ca
  • Channel Quantity: 4
  • Reading Range: Concentration: 0.000 to 999.9, Energy 0 to 65535
  • Test Range: K: 0 to 100 ppm, Na: 0 to 160 ppm, Li: 0 to 100 ppm, Ca: 0 to 1000 ppm
  • Limit Of Detection: K: less than 0.004mmol/L, Na: less than 0.008mmol/L, Li: less than 0.015mmol/L, Ca: less than 0.050mmol/L
Flame Photometer LMFM-A102
  • Test Element: K, Na, Ca
  • Channel Quantity: 3
  • Test Range: K: 0.15 to 100 ppm, Na: 0.18 to 100 ppm, Ca: 0.1 to 1000 ppm
  • Limit Of Detection: K: less than or equal to 0.158 ppm, Na: less than or equal to 0.184 ppm, Ca: less than or equal to 2 ppm
  • Linear Error: K: less than or equal to 0.195 ppm, Na: less than or equal to 0.69 ppm, Ca: less than or equal to 3 ppm

Flame Photometer LMFM- A100

  • Elements Detected: K, Na
  • Sample Uptake: < 6mL/ min
  • Response Time: < 8 s
  • Dimension: 400 × 250 × 500 mm
  • Repeatability: < 3% coefficient of variation for 7 consecutive samples

Flame Photometer LMFM-B102

  • Test Element: K, Na, Ba
  • Channel Quantity: 3
  • Reading Range: Concentration: 0.000 to 999.9, Energy 0 to 65535
  • Test Range: K: 0 to 100 ppm, Na: 0 to 160 ppm, Ba: 0 to 3000 ppm
  • Limit Of Detection: K: less than 0.004mmol/L, Na: less than 0.008mmol/L, Ba: less than 0.044mmol/L

Flame Photometer LMFM-A103

  • Test Element: K, Na, Ca, Li
  • Channel Quantity: 4
  • Test Range: K: 0.15 to 100 ppm, Na: 0.18 to 100 ppm, Li: 0.1 to 30 ppm, Ca: 0.1 to 1000 ppm
  • Limit Of Detection: K: less than or equal to 0.158 ppm, Na: less than or equal to 0.184 ppm, Li: less than or equal to 0.1032 ppm, Ca: less than or equal to 2 ppm
  • Linear Error: K: less than or equal to 0.195 ppm, Na: less than or equal to 0.69 ppm, Li: less than or equal to 0.1449 ppm, Ca: less than or equal to 3 ppm
Flame Photometer LMFM-A101
  • Test Element: K, Na, Li
  • Channel Quantity: 3
  • Test Range: K: 0.15 to 100 ppm, Na: 0.18 to 100 ppm, Li: 0.1 to 30 ppm
  • Limit Of Detection: K: less than or equal to 0.158 ppm, Na: less than or equal to 0.184 ppm, Li: less than or equal to 0.1035 ppm
  • Linear Error: K: less than or equal to 0.195 ppm, Na: less than or equal to 0.69 ppm, Li: less than or equal to 0.1449 ppm

Frequently Asked Questions

1 What is a Flame Photometer?

A Flame Photometer is an apparatus designed to measure the intensity of light emitted by excited atoms or ions in a flame.

2 What is the role of flame temperature in Flame Photometer?

The flame temperature is crucial in determining the excitation of the metal ions.

3 Is Flame Photometer suitable for high-throughput testing?

It provides quick and reliable results therefore is suitable for high-throughput testing.

4 Can Flame Photometer be used for environmental monitoring?

It is used to measure metal ions such as sodium and potassium in water, soil and air samples.

5 How is Calibration done in Flame Photometer?

It is done by preparing a series of standard solutions with known concentrations of the metal ion being analyzed.

6 Is Flame Photometer used in pharmaceutical analysis?

It is used in pharma industry to measure the levels of metals in drug formulations.